(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1_fmu --startTime=0 --stopTime=2e+06 --stepSize=800 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Loads_BaseClasses_Validation_BenchmarkFlowDistribution1.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1 (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 2000000.000000 - tolerance : 1e-06 - stepSize : 800 warning: [fmi2Warning] BenchmarkFlowDistribution1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/SwissResidential_20190916.mos" warning: [fmi2Warning] BenchmarkFlowDistribution1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((noEvent(abs(ter[1].fan.prePow.Q_flow) < 202908.0 * max(0.001 * ter[1].fan.vol.steBal.m_flow_small, abs(ter[1].hex.m2_flow))))) --> "In BenchmarkFlowDistribution1.ter[1].fan.vol.steBal: | | | | The heat flow rate equals 0.711146 W and the mass flow rate equals 0 kg/s, | | | | which results in a temperature difference 7009.54 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] [fmi2Error] BenchmarkFlowDistribution1/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "BenchmarkFlowDistribution1.root.BenchmarkFlowDistribution1" error: [initialize] Initialization of system "BenchmarkFlowDistribution1.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 266, in main handler(args.model, args) File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 139, in _runFMU fmu.initialize() File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 885, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error info: 4 warnings info: 3 errors