/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.Fluid.Movers.Examples.MoverStages_res.mat --tempDir=temp_Buildings_12_Buildings_Fluid_Movers_Examples_MoverStages_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_Fluid_Movers_Examples_MoverStages.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Movers.Examples.MoverStages" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Movers.Examples.MoverStages" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Movers.Examples.MoverStages/model-a817d5oh" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Movers.Examples.MoverStages" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_12_Buildings_Fluid_Movers_Examples_MoverStages.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.000400 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6:3-7:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump_dp.eff.powEu.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump_dp.eff.powEu.P[1], has value: -0.0772891" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7:3-8:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump_dp.eff.powEu_internal.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump_dp.eff.powEu_internal.P[1], has value: -0.0772891" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6:3-7:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump_y.eff.powEu.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump_y.eff.powEu.P[1], has value: -0.0772891" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7:3-8:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump_y.eff.powEu_internal.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump_y.eff.powEu_internal.P[1], has value: -0.0772891" info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.000400 info: Result file: Buildings_12_Buildings.Fluid.Movers.Examples.MoverStages_res.mat (bufferSize=1) info: Parameter model.root.Buildings_12_Buildings_Fluid_Movers_Examples_MoverStages.integerTable.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_12_Buildings_Fluid_Movers_Examples_MoverStages.integerTable.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_12_Buildings_Fluid_Movers_Examples_MoverStages.integerTable.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 1001 NumRhsEvals = 1002 NumLinSolvSetups = 51 NumNonlinSolvIters = 1001 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors