/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass_res.mat --tempDir=temp_Buildings_12_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass_fmu --startTime=1.0368e+07 --stopTime=1.05408e+07 --stepSize=69.12 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass/model-9gscapog" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_12_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass.fmu - startTime: 10368000.000000 - stopTime: 10540800.000000 - tolerance: 0.000001 - stepSize: 69.120000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable] | | | | The following assertion has been violated at time 10368000.000000 | | | | ((tow.cooTowSys.cooTow[2].per.FRWat >= 0.0 and tow.cooTowSys.cooTow[2].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.cooTowSys.cooTow[2].per.FRWat <= 1.0, has value: -5.7176e-34" info: maximum step size for 'model.root': 69.120000 info: Result file: Buildings_12_Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 29 NumRhsEvals = 40 NumLinSolvSetups = 12 NumNonlinSolvIters = 39 NumNonlinSolvConvFails = 0 NumErrTestFails = 2 info: 2 warnings info: 0 errors