Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0007708/0.0007708, allocations: 80.44 kB / 19.17 MB, free: 0.7422 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0008751/0.0008751, allocations: 169.9 kB / 22.46 MB, free: 2.105 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.8603/0.8603, allocations: 177.1 MB / 202.8 MB, free: 5.742 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo): time 0.00141/0.00141, allocations: 225.7 kB / 259.4 MB, free: 13.02 MB / 250.7 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo): time 0.6699/0.6699, allocations: 138.4 MB / 454.3 MB, free: 30 MB / 410.7 MB " [Timeout remaining time 179] Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings,fileNamePrefix="BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings,fileNamePrefix="BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.453e-06/1.453e-06, allocations: 0 / 0.6463 GB, free: 1.859 MB / 0.5573 GB Notification: Performance of FrontEnd - Absyn->SCode: time 1.316e-05/1.461e-05, allocations: 2.281 kB / 0.6463 GB, free: 1.855 MB / 0.5573 GB Notification: Performance of NFInst.instantiate(BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings): time 0.9965/0.9965, allocations: 0.6432 GB / 1.289 GB, free: 9.582 MB / 0.948 GB Notification: Performance of NFInst.instExpressions: time 0.5341/1.531, allocations: 48.96 MB / 1.337 GB, free: 15.94 MB / 0.9636 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01479/1.545, allocations: 0.5122 MB / 1.338 GB, free: 15.94 MB / 0.9636 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). Notification: Performance of NFTyping.typeComponents: time 0.01691/1.562, allocations: 6.428 MB / 1.344 GB, free: 15.88 MB / 0.9636 GB Notification: Performance of NFTyping.typeBindings: time 0.03932/1.602, allocations: 18.69 MB / 1.362 GB, free: 12.82 MB / 0.9636 GB Notification: Performance of NFTyping.typeClassSections: time 0.04527/1.647, allocations: 24.86 MB / 1.387 GB, free: 10.72 MB / 0.9636 GB Notification: Performance of NFFlatten.flatten: time 0.0453/1.692, allocations: 37.51 MB / 1.423 GB, free: 0.9023 MB / 0.9636 GB Notification: Performance of NFFlatten.resolveConnections: time 0.01719/1.709, allocations: 12.31 MB / 1.435 GB, free: 9.059 MB / 0.9792 GB Notification: Performance of NFEvalConstants.evaluate: time 0.04552/1.755, allocations: 22.25 MB / 1.457 GB, free: 12.37 MB / 0.9948 GB Notification: Performance of NFSimplifyModel.simplify: time 0.02066/1.776, allocations: 12.2 MB / 1.469 GB, free: 6.32 MB / 0.9948 GB Notification: Performance of NFPackage.collectConstants: time 0.007003/1.783, allocations: 2.498 MB / 1.471 GB, free: 6.32 MB / 0.9948 GB Notification: Performance of NFFlatten.collectFunctions: time 0.03228/1.815, allocations: 14.74 MB / 1.486 GB, free: 12.39 MB / 1.01 GB Notification: Performance of NFScalarize.scalarize: time 0.01028/1.825, allocations: 7.445 MB / 1.493 GB, free: 5.363 MB / 1.01 GB Notification: Performance of NFVerifyModel.verify: time 0.02177/1.847, allocations: 8.977 MB / 1.502 GB, free: 12.84 MB / 1.026 GB Notification: Performance of NFConvertDAE.convert: time 0.04936/1.896, allocations: 38.22 MB / 1.539 GB, free: 8.578 MB / 1.057 GB Notification: Performance of FrontEnd - DAE generated: time 7.835e-06/1.896, allocations: 0 / 1.539 GB, free: 8.578 MB / 1.057 GB Notification: Performance of FrontEnd: time 2.104e-06/1.896, allocations: 3.938 kB / 1.539 GB, free: 8.574 MB / 1.057 GB Notification: Performance of Transformations before backend: time 0.001124/1.897, allocations: 0 / 1.539 GB, free: 8.574 MB / 1.057 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 4385 * Number of variables: 4385 Notification: Performance of Generate backend data structure: time 0.036/1.933, allocations: 22.48 MB / 1.561 GB, free: 1.828 MB / 1.073 GB Notification: Performance of prepare preOptimizeDAE: time 5.713e-05/1.933, allocations: 9.938 kB / 1.561 GB, free: 1.82 MB / 1.073 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.002919/1.936, allocations: 2.282 MB / 1.563 GB, free: 15.55 MB / 1.089 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.01174/1.948, allocations: 4.271 MB / 1.567 GB, free: 11.29 MB / 1.089 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01716/1.965, allocations: 10.23 MB / 1.577 GB, free: 1.59 MB / 1.089 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0007536/1.966, allocations: 1.316 MB / 1.579 GB, free: 284 kB / 1.089 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.003199/1.969, allocations: 1.817 MB / 1.58 GB, free: 14.46 MB / 1.104 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.03727/2.006, allocations: 27.37 MB / 1.607 GB, free: 1.027 MB / 1.12 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0002936/2.007, allocations: 97.11 kB / 1.607 GB, free: 0.9844 MB / 1.12 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.001454/2.008, allocations: 0.7979 MB / 1.608 GB, free: 196 kB / 1.12 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0003225/2.009, allocations: 0.559 MB / 1.609 GB, free: 15.64 MB / 1.135 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.02375/2.032, allocations: 18.1 MB / 1.626 GB, free: 13.88 MB / 1.151 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.09145/2.124, allocations: 89.01 MB / 1.713 GB, free: 4.52 MB / 1.229 GB Notification: Performance of preOpt comSubExp (simulation): time 0.009865/2.134, allocations: 8.712 MB / 1.722 GB, free: 11.37 MB / 1.245 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.006246/2.14, allocations: 5.537 MB / 1.727 GB, free: 5.551 MB / 1.245 GB Notification: Performance of preOpt evalFunc (simulation): time 0.001509/2.141, allocations: 0.7148 MB / 1.728 GB, free: 4.844 MB / 1.245 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0001348/2.141, allocations: 191.3 kB / 1.728 GB, free: 4.668 MB / 1.245 GB Notification: Performance of pre-optimization done (n=740): time 7.845e-06/2.141, allocations: 0 / 1.728 GB, free: 4.668 MB / 1.245 GB Notification: Performance of matching and sorting (n=740): time 0.02037/2.162, allocations: 15.88 MB / 1.744 GB, free: 4.484 MB / 1.26 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0006479/2.163, allocations: 2.202 MB / 1.746 GB, free: 1.828 MB / 1.26 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.3016/2.464, allocations: 13.92 MB / 1.759 GB, free: 0.6849 GB / 1.26 GB Notification: Performance of collectPreVariables (initialization): time 0.001996/2.466, allocations: 212.9 kB / 1.759 GB, free: 0.6847 GB / 1.26 GB Notification: Performance of collectInitialEqns (initialization): time 0.003672/2.47, allocations: 8.471 MB / 1.768 GB, free: 0.6804 GB / 1.26 GB Notification: Performance of collectInitialBindings (initialization): time 0.002766/2.473, allocations: 2.823 MB / 1.771 GB, free: 0.6782 GB / 1.26 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.002618/2.475, allocations: 2.657 MB / 1.773 GB, free: 0.6771 GB / 1.26 GB Notification: Performance of setup shared object (initialization): time 3.261e-05/2.475, allocations: 315.3 kB / 1.773 GB, free: 0.6768 GB / 1.26 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.005903/2.481, allocations: 6.12 MB / 1.779 GB, free: 0.6735 GB / 1.26 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.007613/2.489, allocations: 11.05 MB / 1.79 GB, free: 0.6641 GB / 1.26 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.01392/2.503, allocations: 16.58 MB / 1.806 GB, free: 0.6515 GB / 1.26 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 9.833e-05/2.503, allocations: 49.56 kB / 1.806 GB, free: 0.6515 GB / 1.26 GB Notification: Performance of matching and sorting (n=1615) (initialization): time 0.02113/2.524, allocations: 18.75 MB / 1.825 GB, free: 0.6421 GB / 1.26 GB Notification: Performance of prepare postOptimizeDAE: time 0.0004159/2.524, allocations: 1.56 MB / 1.826 GB, free: 0.6406 GB / 1.26 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001452/2.524, allocations: 159.9 kB / 1.826 GB, free: 0.6406 GB / 1.26 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0001596/2.525, allocations: 234.2 kB / 1.827 GB, free: 0.6406 GB / 1.26 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.005684/2.53, allocations: 3.001 MB / 1.83 GB, free: 0.6403 GB / 1.26 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.003129/2.533, allocations: 17.11 MB / 1.846 GB, free: 0.6238 GB / 1.26 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.009496/2.543, allocations: 1.877 MB / 1.848 GB, free: 0.6227 GB / 1.26 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001063/2.544, allocations: 0.7525 MB / 1.849 GB, free: 0.6226 GB / 1.26 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 728 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1516): * Single equations (assignments): 1440 * Array equations: 0 * Algorithm blocks: 48 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 28 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 28 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Performance of prepare postOptimizeDAE: time 0.006216/2.55, allocations: 4.142 MB / 1.853 GB, free: 0.6201 GB / 1.26 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.002816/2.553, allocations: 1.599 MB / 1.854 GB, free: 0.6193 GB / 1.26 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01144/2.564, allocations: 11.75 MB / 1.866 GB, free: 0.6139 GB / 1.26 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 3.646e-05/2.564, allocations: 72.56 kB / 1.866 GB, free: 0.6139 GB / 1.26 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.577e-05/2.565, allocations: 15.47 kB / 1.866 GB, free: 0.6139 GB / 1.26 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 3.525e-05/2.565, allocations: 44.59 kB / 1.866 GB, free: 0.6139 GB / 1.26 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.03314/2.598, allocations: 32.78 MB / 1.898 GB, free: 0.5878 GB / 1.26 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.842e-05/2.598, allocations: 20 kB / 1.898 GB, free: 0.5878 GB / 1.26 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.003476/2.601, allocations: 1.566 MB / 1.9 GB, free: 0.5863 GB / 1.26 GB Notification: Performance of postOpt tearingSystem (simulation): time 2.603e-05/2.601, allocations: 44 kB / 1.9 GB, free: 0.5863 GB / 1.26 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0004384/2.602, allocations: 347.6 kB / 1.9 GB, free: 0.586 GB / 1.26 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.002519/2.604, allocations: 16.84 MB / 1.916 GB, free: 0.5689 GB / 1.26 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.005e-05/2.604, allocations: 31.88 kB / 1.916 GB, free: 0.5689 GB / 1.26 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.0172/2.621, allocations: 19.63 MB / 1.936 GB, free: 0.5487 GB / 1.26 GB Notification: Performance of postOpt removeConstants (simulation): time 0.005502/2.627, allocations: 2.918 MB / 1.938 GB, free: 0.5458 GB / 1.26 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001966/2.629, allocations: 223.9 kB / 1.939 GB, free: 0.5456 GB / 1.26 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.005228/2.634, allocations: 432.6 kB / 1.939 GB, free: 0.5452 GB / 1.26 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0007526/2.635, allocations: 0.6782 MB / 1.94 GB, free: 0.5445 GB / 1.26 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0005275/2.635, allocations: 423.6 kB / 1.94 GB, free: 0.5441 GB / 1.26 GB Notification: Performance of sorting global known variables: time 0.009121/2.644, allocations: 9.015 MB / 1.949 GB, free: 0.5353 GB / 1.26 GB Notification: Performance of sort global known variables: time 1.91e-07/2.644, allocations: 0 / 1.949 GB, free: 0.5353 GB / 1.26 GB Notification: Performance of remove unused functions: time 0.01145/2.656, allocations: 4.663 MB / 1.954 GB, free: 0.5308 GB / 1.26 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 101 * Number of states: 90 (airEle111.fluid.rho,airEle111.fluid.h,airEle211.fluid.rho,airEle211.fluid.h,flowConnectionX_111_112.v,west11.ori.mExc,west11.senTem.T,floor11.ori.mExc,floor11.senTem.T,north11.ori.mExc,north11.senTem.T,south11.ori.mExc,south11.senTem.T,floor21.ori.mExc,floor21.senTem.T,south21.ori.mExc,south21.senTem.T,north21.ori.mExc,north21.senTem.T,flowConnectionX_211_311.v,airEle311.fluid.rho,airEle311.fluid.h,east11.ori.mExc,east11.senTem.T,floor31.ori.mExc,floor31.senTem.T,north31.ori.mExc,north31.senTem.T,south31.ori.mExc,south31.senTem.T,airEle121.fluid.rho,airEle121.fluid.h,airEle221.fluid.rho,airEle221.fluid.h,flowConnectionX_121_221.v,west21.ori.mExc,west21.senTem.T,north12.ori.mExc,north12.senTem.T,south12.ori.mExc,south12.senTem.T,south22.ori.mExc,south22.senTem.T,west22.ori.mExc,west22.senTem.T,flowConnectionX_221_321.v,airEle321.fluid.rho,airEle321.fluid.h,east12.ori.mExc,east12.senTem.T,north32.ori.mExc,north32.senTem.T,south32.ori.mExc,south32.senTem.T,airEle131.fluid.rho,airEle131.fluid.h,airEle231.fluid.rho,airEle231.fluid.h,flowConnectionX_131_231.v,west31.ori.mExc,west31.senTem.T,roof11.ori.mExc,roof11.senTem.T,north13.ori.mExc,north13.senTem.T,south13.ori.mExc,south13.senTem.T,south23.ori.mExc,south23.senTem.T,roof21.ori.mExc,roof21.senTem.T,north23.ori.mExc,north23.senTem.T,flowConnectionX_231_331.v,airEle331.fluid.rho,airEle331.fluid.h,east13.ori.mExc,east13.senTem.T,roof31.ori.mExc,roof31.senTem.T,north33.ori.mExc,north33.senTem.T,south33.ori.mExc,south33.senTem.T,flowConnectionY_111_121.v,flowConnectionY_211_221.v,flowConnectionY_311_321.v,flowConnectionY_111_131.v,flowConnectionY_221_231.v,flowConnectionY_321_331.v) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (641): * Single equations (assignments): 595 * Array equations: 0 * Algorithm blocks: 18 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 28 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 28 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Performance of Backend phase and start with SimCode phase: time 0.01881/2.675, allocations: 21.12 MB / 1.974 GB, free: 0.5093 GB / 1.26 GB Notification: Performance of simCode: created initialization part: time 0.01434/2.689, allocations: 16.56 MB / 1.99 GB, free: 0.4922 GB / 1.26 GB Notification: Performance of simCode: created event and clocks part: time 1.988e-05/2.689, allocations: 8.5 kB / 1.99 GB, free: 0.4922 GB / 1.26 GB Notification: Performance of simCode: created simulation system equations: time 0.007265/2.696, allocations: 8.268 MB / 1.998 GB, free: 495.4 MB / 1.26 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01317/2.71, allocations: 4.412 MB / 2.003 GB, free: 491.4 MB / 1.26 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.1654/2.875, allocations: 141.3 MB / 2.141 GB, free: 342.5 MB / 1.26 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.004514/2.879, allocations: 7.414 MB / 2.148 GB, free: 335.1 MB / 1.26 GB Notification: Performance of simCode: alias equations: time 0.006429/2.886, allocations: 2.417 MB / 2.15 GB, free: 332.7 MB / 1.26 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.004436/2.89, allocations: 7.459 MB / 2.158 GB, free: 325.2 MB / 1.26 GB Notification: Performance of SimCode: time 1.293e-06/2.89, allocations: 0 / 2.158 GB, free: 325.2 MB / 1.26 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.5593/3.45, allocations: 364.3 MB / 2.513 GB, free: 0.6459 GB / 1.26 GB Error: Error building simulator. Build log: cmd: cd '464.fmutmp/sources/' && mkdir build_cmake_static && cd build_cmake_static && cmake -DCMAKE_BUILD_TYPE=Release -DCMAKE_C_COMPILER='clang' .. && cmake --build . --parallel -j1 --target install && cd .. && rm -rf build_cmake_static -- The C compiler identification is Clang 18.1.3 -- Detecting C compiler ABI info -- Detecting C compiler ABI info - done -- Check for working C compiler: /usr/bin/clang - skipped -- Detecting C compile features -- Detecting C compile features - done -- FMI2 include directory: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/fmi -- Performing Test CMAKE_HAVE_LIBC_PTHREAD -- Performing Test CMAKE_HAVE_LIBC_PTHREAD - Success -- Found Threads: TRUE -- Building for FMI platform linux64 -- Install directory: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/../binaries/linux64 -- CVODE: Not linked -- Not using FMI2_FUNCTION_PREFIX -- Installing dynamic dependencies from list: -- Configuring done (0.2s) -- Generating done (0.0s) -- Build files have been written to: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/build_cmake_static [ 0%] Building C object CMakeFiles/464.dir/external_solvers/F77_aloc.c.o [ 1%] Building C object CMakeFiles/464.dir/external_solvers/dgemm.c.o [ 2%] Building C object CMakeFiles/464.dir/external_solvers/dgemv.c.o [ 3%] Building C object CMakeFiles/464.dir/external_solvers/dger.c.o [ 4%] Building C object CMakeFiles/464.dir/external_solvers/dgesv.c.o [ 4%] Building C object CMakeFiles/464.dir/external_solvers/dgetf2.c.o [ 5%] Building C object CMakeFiles/464.dir/external_solvers/dgetrf.c.o [ 6%] Building C object CMakeFiles/464.dir/external_solvers/dgetri.c.o [ 7%] Building C object CMakeFiles/464.dir/external_solvers/dgetrs.c.o [ 8%] Building C object CMakeFiles/464.dir/external_solvers/dlamch.c.o [ 8%] Building C object CMakeFiles/464.dir/external_solvers/dlaswp.c.o [ 9%] Building C object CMakeFiles/464.dir/external_solvers/dogleg_.c.o [ 10%] Building C object CMakeFiles/464.dir/external_solvers/dpmpar_.c.o [ 11%] Building C object CMakeFiles/464.dir/external_solvers/dscal.c.o [ 12%] Building C object CMakeFiles/464.dir/external_solvers/dswap.c.o [ 13%] Building C object CMakeFiles/464.dir/external_solvers/dtrmm.c.o [ 13%] Building C object CMakeFiles/464.dir/external_solvers/dtrmv.c.o [ 14%] Building C object CMakeFiles/464.dir/external_solvers/dtrsm.c.o [ 15%] Building C object CMakeFiles/464.dir/external_solvers/dtrti2.c.o [ 16%] Building C object CMakeFiles/464.dir/external_solvers/dtrtri.c.o [ 17%] Building C object CMakeFiles/464.dir/external_solvers/enorm_.c.o [ 17%] Building C object CMakeFiles/464.dir/external_solvers/exit_.c.o [ 18%] Building C object CMakeFiles/464.dir/external_solvers/hybrj_.c.o [ 19%] Building C object CMakeFiles/464.dir/external_solvers/i_nint.c.o [ 20%] Building C object CMakeFiles/464.dir/external_solvers/idamax.c.o [ 21%] Building C object CMakeFiles/464.dir/external_solvers/ieeeck.c.o [ 21%] Building C object CMakeFiles/464.dir/external_solvers/ilaenv.c.o [ 22%] Building C object CMakeFiles/464.dir/external_solvers/iparmq.c.o [ 23%] Building C object CMakeFiles/464.dir/external_solvers/lsame.c.o [ 24%] Building C object CMakeFiles/464.dir/external_solvers/pow_di.c.o [ 25%] Building C object CMakeFiles/464.dir/external_solvers/qform_.c.o [ 26%] Building C object CMakeFiles/464.dir/external_solvers/qrfac_.c.o [ 26%] Building C object CMakeFiles/464.dir/external_solvers/r1mpyq_.c.o [ 27%] Building C object CMakeFiles/464.dir/external_solvers/r1updt_.c.o [ 28%] Building C object CMakeFiles/464.dir/external_solvers/s_cat.c.o [ 29%] Building C object CMakeFiles/464.dir/external_solvers/s_cmp.c.o [ 30%] Building C object CMakeFiles/464.dir/external_solvers/s_copy.c.o [ 30%] Building C object CMakeFiles/464.dir/external_solvers/xerbla.c.o [ 31%] Building C object CMakeFiles/464.dir/fmi-export/fmu2_model_interface.c.o [ 32%] Building C object CMakeFiles/464.dir/fmi-export/fmu_read_flags.c.o [ 33%] Building C object CMakeFiles/464.dir/gc/memory_pool.c.o [ 34%] Building C object CMakeFiles/464.dir/gc/omc_gc.c.o [ 34%] Building C object CMakeFiles/464.dir/math-support/pivot.c.o [ 35%] Building C object CMakeFiles/464.dir/meta/meta_modelica_catch.c.o [ 36%] Building C object CMakeFiles/464.dir/simulation/arrayIndex.c.o [ 37%] Building C object CMakeFiles/464.dir/simulation/eval_dep.c.o [ 38%] Building C object CMakeFiles/464.dir/simulation/jacobian_util.c.o [ 39%] Building C object CMakeFiles/464.dir/simulation/omc_simulation_util.c.o [ 39%] Building C object CMakeFiles/464.dir/simulation/options.c.o [ 40%] Building C object CMakeFiles/464.dir/simulation/simulation_info_json.c.o [ 41%] Building C object CMakeFiles/464.dir/simulation/simulation_omc_assert.c.o [ 42%] Building C object CMakeFiles/464.dir/simulation/solver/delay.c.o [ 43%] Building C object CMakeFiles/464.dir/simulation/solver/discrete_changes.c.o [ 43%] Building C object CMakeFiles/464.dir/simulation/solver/initialization/initialization.c.o [ 44%] Building C object CMakeFiles/464.dir/simulation/solver/model_help.c.o [ 45%] Building C object CMakeFiles/464.dir/simulation/solver/nonlinearSolverHomotopy.c.o [ 46%] Building C object CMakeFiles/464.dir/simulation/solver/nonlinearSolverHybrd.c.o [ 47%] Building C object CMakeFiles/464.dir/simulation/solver/nonlinearSystem.c.o [ 47%] Building C object CMakeFiles/464.dir/simulation/solver/nonlinearValuesList.c.o [ 48%] Building C object CMakeFiles/464.dir/simulation/solver/omc_math.c.o [ 49%] Building C object CMakeFiles/464.dir/simulation/solver/spatialDistribution.c.o [ 50%] Building C object CMakeFiles/464.dir/simulation/solver/stateset.c.o [ 51%] Building C object CMakeFiles/464.dir/simulation/solver/synchronous.c.o [ 52%] Building C object CMakeFiles/464.dir/util/ModelicaUtilities.c.o [ 52%] Building C object CMakeFiles/464.dir/util/base_array.c.o [ 53%] Building C object CMakeFiles/464.dir/util/boolean_array.c.o [ 54%] Building C object CMakeFiles/464.dir/util/context.c.o [ 55%] Building C object CMakeFiles/464.dir/util/division.c.o [ 56%] Building C object CMakeFiles/464.dir/util/doubleEndedList.c.o [ 56%] Building C object CMakeFiles/464.dir/util/generic_array.c.o [ 57%] Building C object CMakeFiles/464.dir/util/index_spec.c.o [ 58%] Building C object CMakeFiles/464.dir/util/integer_array.c.o [ 59%] Building C object CMakeFiles/464.dir/util/list.c.o [ 60%] Building C object CMakeFiles/464.dir/util/modelica_string.c.o [ 60%] Building C object CMakeFiles/464.dir/util/modelica_string_lit.c.o [ 61%] Building C object CMakeFiles/464.dir/util/omc_error.c.o [ 62%] Building C object CMakeFiles/464.dir/util/omc_file.c.o [ 63%] Building C object CMakeFiles/464.dir/util/omc_init.c.o [ 64%] Building C object CMakeFiles/464.dir/util/omc_mmap.c.o [ 65%] Building C object CMakeFiles/464.dir/util/omc_msvc.c.o [ 65%] Building C object CMakeFiles/464.dir/util/omc_numbers.c.o [ 66%] Building C object CMakeFiles/464.dir/util/parallel_helper.c.o [ 67%] Building C object CMakeFiles/464.dir/util/rational.c.o [ 68%] Building C object CMakeFiles/464.dir/util/real_array.c.o [ 69%] Building C object CMakeFiles/464.dir/util/ringbuffer.c.o [ 69%] Building C object CMakeFiles/464.dir/util/simulation_options.c.o [ 70%] Building C object CMakeFiles/464.dir/util/string_array.c.o [ 71%] Building C object CMakeFiles/464.dir/util/utility.c.o [ 72%] Building C object CMakeFiles/464.dir/util/varinfo.c.o [ 73%] Building C object CMakeFiles/464.dir/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c.o /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:4960:457: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4960 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:4968:478: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4968 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:4976:589: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4976 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */) + (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:4993:459: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4993 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5001:480: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5001 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5022:509: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5022 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = (fmin(0.05,log(tmp31))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5039:480: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5039 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5047:463: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5047 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5068:492: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5068 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = (fmin(0.05,log(tmp38))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5085:463: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5085 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5106:492: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5106 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = (fmin(0.05,log(tmp43))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5114:486: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5114 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5135:515: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5135 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = (fmin(0.05,log(tmp48))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5143:599: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5143 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[201]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1382]] /* west11.ori.m_flow variable */) + (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[600]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5167:476: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5167 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[2] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[694]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5181:478: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5181 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[2] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[694]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5201:507: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5201 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[2] variable */) = (fmin(0.05,log(tmp54))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[694]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5217:480: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5217 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[2] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[694]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1WithOpenings/464.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c:5252:509: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5252 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[2] variable */) = (fmin(0.05,log(tmp59))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[694]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. gmake[2]: *** [CMakeFiles/464.dir/build.make:1322: CMakeFiles/464.dir/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1WithOpenings.c.o] Error 1 gmake[1]: *** [CMakeFiles/Makefile2:84: CMakeFiles/464.dir/all] Error 2 gmake: *** [Makefile:136: all] Error 2 " [Timeout remaining time 650] [Calling sys.exit(0), Time elapsed: 12.314730666577816] Failed to read output from testmodel.py, exit status != 0: 9.943631060421467 9.952284144 8.054034869 Calling exit ...