/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Systems_ModularAHU_Examples_Heater_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Systems_ModularAHU_Examples_Heater.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.Heater" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.Heater" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.Heater/model-a6ppv2ty" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.Heater" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_Systems_ModularAHU_Examples_Heater.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.0/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6:3-7:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((registerModule.hydraulicModule.PumpInterface.pump.eff.powEu.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= registerModule.hydraulicModule.PumpInterface.pump.eff.powEu.P[1], has value: -0.0772891" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.0/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7:3-8:55:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((registerModule.hydraulicModule.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= registerModule.hydraulicModule.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.0772891" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.0/Media/Water.mo:63:5-64:119:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((noEvent(registerModule.hydraulicModule.junc456.dynBal.medium.T >= 272.15))) --> "In Heater.registerModule.hydraulicModule.junc456.dynBal.medium: Temperature T = -4.55934e+06 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Systems_ModularAHU_Examples_Heater/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.AixLib_AixLib_Systems_ModularAHU_Examples_Heater" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors