Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermalSeparation_ThermalSeparation.Examples.Absorption_IdealGases_Tray.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0009395/0.0009395, allocations: 72.5 kB / 19.92 MB, free: 4.633 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001144/0.001144, allocations: 177.9 kB / 23.21 MB, free: 1.348 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.8746/0.8746, allocations: 177.1 MB / 203.5 MB, free: 5.719 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo): time 0.3107/0.3107, allocations: 50.76 MB / 310.7 MB, free: 5.176 MB / 282.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:146:3-158:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:160:3-168:15:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:145:4-157:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:159:5-167:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:320:4-332:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:334:5-342:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 180] Using package ThermalSeparation with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermalSeparation.Examples.Absorption_IdealGases_Tray,fileNamePrefix="ThermalSeparation_ThermalSeparation_Examples_Absorption_IdealGases_Tray",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermalSeparation.Examples.Absorption_IdealGases_Tray,fileNamePrefix="ThermalSeparation_ThermalSeparation_Examples_Absorption_IdealGases_Tray",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Warning: Ignoring unknown experiment annotation option: Algorithm = \"Dassl\" Notification: Performance of FrontEnd - loaded program: time 2.004e-06/2.004e-06, allocations: 0 / 462 MB, free: 29.95 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.713e-05/1.914e-05, allocations: 4.812 kB / 462 MB, free: 29.95 MB / 410.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Media/WaterBasedLiquid/BaseClasses/package.mo:6:3-23:32:writable] Error: PartialWaterBased is partial, name lookup is not allowed in partial classes. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Media/WaterBasedLiquid/N2_O2_H2O.mo:7:3-25:30:writable] Error: Base class ThermalSeparation.Media.WaterBasedLiquid.BaseClasses.PartialWaterBased not found in scope N2_O2_H2O. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/SourcesSinks/SourceLiquid.mo:6:5-6:92:writable] Error: Class MediumLiquid.BaseProperties not found in scope SourceLiquid. Notification: Performance of FrontEnd: time 0.00133/0.001349, allocations: 0.9379 MB / 462.9 MB, free: 29.32 MB / 410.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 1.9473329288884997] Failed to read output from testmodel.py, exit status != 0: 0.0039573004469275475 0.010362481000000002 -1.0 Calling exit ...