Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermalSeparation_ThermalSeparation.Examples.Absorption_CO2_MEA.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0007572/0.0007572, allocations: 76.5 kB / 19.93 MB, free: 4.633 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0007621/0.0007621, allocations: 173.9 kB / 23.21 MB, free: 1.352 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.857/0.857, allocations: 177.1 MB / 203.5 MB, free: 5.754 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo): time 0.332/0.332, allocations: 50.76 MB / 310.7 MB, free: 5.215 MB / 282.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:146:3-158:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:160:3-168:15:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:145:4-157:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:159:5-167:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:320:4-332:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:334:5-342:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 180] Using package ThermalSeparation with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermalSeparation.Examples.Absorption_CO2_MEA,fileNamePrefix="ThermalSeparation_ThermalSeparation_Examples_Absorption_CO2_MEA",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermalSeparation.Examples.Absorption_CO2_MEA,fileNamePrefix="ThermalSeparation_ThermalSeparation_Examples_Absorption_CO2_MEA",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Warning: Ignoring unknown experiment annotation option: Algorithm = \"Dassl\" Notification: Performance of FrontEnd - loaded program: time 2.525e-06/2.525e-06, allocations: 0 / 462 MB, free: 29.96 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.938e-05/2.19e-05, allocations: 5.156 kB / 462 MB, free: 29.95 MB / 410.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Media/IdealGasMixtures/BaseClasses/BaseIdealGasMixture.mo:32:3-34:73:writable] Error: BaseIdealGasMixture is partial, name lookup is not allowed in partial classes. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Columns/BaseClasses/BaseColumn.mo:75:2-75:113:writable] Error: Class MediumVapour.BaseProperties not found in scope BaseColumn. Notification: Performance of FrontEnd: time 0.09877/0.09879, allocations: 118.7 MB / 0.567 GB, free: 15.98 MB / 490.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.030929194763303] Failed to read output from testmodel.py, exit status != 0: 0.10258371755480766 0.11108598900000001 -1.0 Calling exit ...