Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001345/0.001345, allocations: 80.44 kB / 19.17 MB, free: 0.7422 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001463/0.001463, allocations: 165.9 kB / 22.45 MB, free: 2.109 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.084/1.084, allocations: 177.1 MB / 202.8 MB, free: 5.75 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo): time 0.002039/0.002039, allocations: 234.2 kB / 259.4 MB, free: 13.03 MB / 250.7 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo): time 0.8047/0.8047, allocations: 138.4 MB / 454.3 MB, free: 29.99 MB / 410.7 MB " [Timeout remaining time 179] Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1,fileNamePrefix="BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1,fileNamePrefix="BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.793e-06/1.793e-06, allocations: 0 / 0.6463 GB, free: 1.848 MB / 0.5573 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.379e-05/2.558e-05, allocations: 2.281 kB / 0.6463 GB, free: 1.844 MB / 0.5573 GB Notification: Performance of NFInst.instantiate(BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1): time 1.593/1.593, allocations: 0.6362 GB / 1.283 GB, free: 476 kB / 0.9323 GB Notification: Performance of NFInst.instExpressions: time 0.8915/2.485, allocations: 48.63 MB / 1.33 GB, free: 15.97 MB / 0.9636 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02725/2.512, allocations: 0.5029 MB / 1.331 GB, free: 15.97 MB / 0.9636 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Examples/BoundaryTemp.mo:4:3-5:70:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionX.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:129:3-132:57:writable] Warning: Connector flowPort_X1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:133:3-136:54:writable] Warning: Connector flowPort_X2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:137:3-140:56:writable] Warning: Connector flowPort_Y1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:141:3-144:54:writable] Warning: Connector flowPort_Y2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:145:3-148:57:writable] Warning: Connector flowPort_Z1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:149:3-152:53:writable] Warning: Connector flowPort_Z2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:154:3-156:56:writable] Warning: Connector heatPort_intern is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirElementGeneral.mo:162:3-162:81:writable] Warning: Connector assessementPort is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:5:3-8:52:writable] Warning: Connector PortF is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Interfaces/Boundary.mo:14:3-17:55:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:32:3-33:121:writable] Warning: Connector port_1 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/FlowConnection.mo:34:3-35:80:writable] Warning: Connector port_2 is not balanced: The number of potential variables (13) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:5:3-7:54:writable] Warning: Connector port_1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/FlowConnections/ZoneHeatConductionY.mo:8:3-10:52:writable] Warning: Connector port_2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Airvolumes/Examples/BoundaryTemp.mo:4:3-5:70:writable] Warning: Connector surfaceToAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.02969/2.542, allocations: 6.368 MB / 1.337 GB, free: 15.96 MB / 0.9636 GB Notification: Performance of NFTyping.typeBindings: time 0.07451/2.616, allocations: 18.39 MB / 1.355 GB, free: 13.03 MB / 0.9636 GB Notification: Performance of NFTyping.typeClassSections: time 0.07373/2.69, allocations: 24.7 MB / 1.379 GB, free: 10.93 MB / 0.9636 GB Notification: Performance of NFFlatten.flatten: time 0.07868/2.769, allocations: 37.32 MB / 1.415 GB, free: 4.094 MB / 0.9636 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04234/2.811, allocations: 12.36 MB / 1.427 GB, free: 13.61 MB / 0.9792 GB Notification: Performance of NFEvalConstants.evaluate: time 0.07746/2.889, allocations: 22.2 MB / 1.449 GB, free: 0.9375 MB / 0.9792 GB Notification: Performance of NFSimplifyModel.simplify: time 0.0339/2.923, allocations: 12.17 MB / 1.461 GB, free: 10.89 MB / 0.9948 GB Notification: Performance of NFPackage.collectConstants: time 0.01184/2.934, allocations: 2.508 MB / 1.463 GB, free: 10.89 MB / 0.9948 GB Notification: Performance of NFFlatten.collectFunctions: time 0.04494/2.979, allocations: 14.54 MB / 1.478 GB, free: 2.617 MB / 0.9948 GB Notification: Performance of NFScalarize.scalarize: time 0.01713/2.996, allocations: 7.425 MB / 1.485 GB, free: 11.61 MB / 1.01 GB Notification: Performance of NFVerifyModel.verify: time 0.04284/3.039, allocations: 9.005 MB / 1.494 GB, free: 3.051 MB / 1.01 GB Notification: Performance of NFConvertDAE.convert: time 0.08627/3.126, allocations: 38.2 MB / 1.531 GB, free: 14.8 MB / 1.057 GB Notification: Performance of FrontEnd - DAE generated: time 1.445e-05/3.126, allocations: 0 / 1.531 GB, free: 14.8 MB / 1.057 GB Notification: Performance of FrontEnd: time 3.707e-06/3.126, allocations: 3.938 kB / 1.531 GB, free: 14.79 MB / 1.057 GB Notification: Performance of Transformations before backend: time 0.002072/3.128, allocations: 4 kB / 1.531 GB, free: 14.79 MB / 1.057 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 4401 * Number of variables: 4401 Notification: Performance of Generate backend data structure: time 0.0716/3.199, allocations: 22.48 MB / 1.553 GB, free: 8.031 MB / 1.073 GB Notification: Performance of prepare preOptimizeDAE: time 5.617e-05/3.199, allocations: 9.938 kB / 1.553 GB, free: 8.023 MB / 1.073 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.009221/3.209, allocations: 2.28 MB / 1.555 GB, free: 5.738 MB / 1.073 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02246/3.231, allocations: 4.256 MB / 1.559 GB, free: 1.496 MB / 1.073 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.03662/3.268, allocations: 10.19 MB / 1.569 GB, free: 7.832 MB / 1.089 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.002086/3.27, allocations: 1.312 MB / 1.57 GB, free: 6.523 MB / 1.089 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01126/3.281, allocations: 1.831 MB / 1.572 GB, free: 4.695 MB / 1.089 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.07407/3.355, allocations: 27.4 MB / 1.599 GB, free: 7.223 MB / 1.12 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001055/3.356, allocations: 101.5 kB / 1.599 GB, free: 7.176 MB / 1.12 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.01126/3.367, allocations: 0.7972 MB / 1.6 GB, free: 6.383 MB / 1.12 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0006056/3.368, allocations: 0.5646 MB / 1.6 GB, free: 5.824 MB / 1.12 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.05678/3.425, allocations: 18.08 MB / 1.618 GB, free: 4.094 MB / 1.135 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.1647/3.589, allocations: 88.99 MB / 1.705 GB, free: 10.73 MB / 1.229 GB Notification: Performance of preOpt comSubExp (simulation): time 0.0153/3.605, allocations: 8.566 MB / 1.713 GB, free: 1.707 MB / 1.229 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.01102/3.616, allocations: 5.347 MB / 1.719 GB, free: 12.07 MB / 1.245 GB Notification: Performance of preOpt evalFunc (simulation): time 0.00205/3.618, allocations: 0.6446 MB / 1.719 GB, free: 11.43 MB / 1.245 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0004096/3.618, allocations: 199.9 kB / 1.719 GB, free: 11.25 MB / 1.245 GB Notification: Performance of pre-optimization done (n=726): time 1.098e-05/3.618, allocations: 3.984 kB / 1.719 GB, free: 11.24 MB / 1.245 GB Notification: Performance of matching and sorting (n=726): time 0.04989/3.668, allocations: 15.34 MB / 1.734 GB, free: 11.6 MB / 1.26 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.001606/3.67, allocations: 2.294 MB / 1.737 GB, free: 8.828 MB / 1.26 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.9497/4.619, allocations: 13.87 MB / 1.75 GB, free: 249.3 MB / 1.26 GB Notification: Performance of collectPreVariables (initialization): time 0.003285/4.623, allocations: 211.4 kB / 1.75 GB, free: 249.3 MB / 1.26 GB Notification: Performance of collectInitialEqns (initialization): time 0.01245/4.635, allocations: 8.508 MB / 1.759 GB, free: 248.3 MB / 1.26 GB Notification: Performance of collectInitialBindings (initialization): time 0.005669/4.641, allocations: 2.783 MB / 1.761 GB, free: 246.9 MB / 1.26 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.01228/4.653, allocations: 2.618 MB / 1.764 GB, free: 246.6 MB / 1.26 GB Notification: Performance of setup shared object (initialization): time 3.941e-05/4.653, allocations: 303.9 kB / 1.764 GB, free: 246.3 MB / 1.26 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.01103/4.664, allocations: 5.972 MB / 1.77 GB, free: 244.8 MB / 1.26 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.01525/4.679, allocations: 10.85 MB / 1.781 GB, free: 237.3 MB / 1.26 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.03272/4.712, allocations: 16.41 MB / 1.797 GB, free: 229.2 MB / 1.26 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0007797/4.713, allocations: 49.12 kB / 1.797 GB, free: 229.2 MB / 1.26 GB Notification: Performance of matching and sorting (n=1611) (initialization): time 0.05507/4.768, allocations: 18.47 MB / 1.815 GB, free: 225.2 MB / 1.26 GB Notification: Performance of prepare postOptimizeDAE: time 0.001705/4.77, allocations: 1.556 MB / 1.816 GB, free: 223.7 MB / 1.26 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0004205/4.77, allocations: 163.6 kB / 1.816 GB, free: 223.7 MB / 1.26 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0003713/4.77, allocations: 232.5 kB / 1.817 GB, free: 223.7 MB / 1.26 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01089/4.781, allocations: 3.019 MB / 1.82 GB, free: 223.7 MB / 1.26 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.006609/4.788, allocations: 18.32 MB / 1.838 GB, free: 206.1 MB / 1.26 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.02058/4.809, allocations: 1.858 MB / 1.839 GB, free: 205.4 MB / 1.26 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.005847/4.814, allocations: 0.7414 MB / 1.84 GB, free: 205.4 MB / 1.26 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 742 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1512): * Single equations (assignments): 1434 * Array equations: 0 * Algorithm blocks: 48 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 30 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 30 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Performance of prepare postOptimizeDAE: time 0.01809/4.832, allocations: 4.126 MB / 1.844 GB, free: 204.6 MB / 1.26 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.008782/4.841, allocations: 1.587 MB / 1.846 GB, free: 203.8 MB / 1.26 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.03397/4.875, allocations: 11.33 MB / 1.857 GB, free: 202.3 MB / 1.26 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 9.73e-05/4.875, allocations: 73.97 kB / 1.857 GB, free: 202.3 MB / 1.26 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.902e-05/4.875, allocations: 18 kB / 1.857 GB, free: 202.3 MB / 1.26 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.0001554/4.876, allocations: 42.2 kB / 1.857 GB, free: 202.3 MB / 1.26 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.08738/4.963, allocations: 31.81 MB / 1.888 GB, free: 194.8 MB / 1.26 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 4.047e-05/4.963, allocations: 23.38 kB / 1.888 GB, free: 194.8 MB / 1.26 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.005858/4.969, allocations: 1.544 MB / 1.889 GB, free: 194.7 MB / 1.26 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.0002838/4.969, allocations: 40.22 kB / 1.889 GB, free: 194.7 MB / 1.26 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.003098/4.972, allocations: 332.4 kB / 1.89 GB, free: 194.7 MB / 1.26 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.004923/4.977, allocations: 18.04 MB / 1.907 GB, free: 177.1 MB / 1.26 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.879e-05/4.977, allocations: 34.06 kB / 1.907 GB, free: 177.1 MB / 1.26 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.04144/5.019, allocations: 18.9 MB / 1.926 GB, free: 166.9 MB / 1.26 GB Notification: Performance of postOpt removeConstants (simulation): time 0.0139/5.032, allocations: 2.847 MB / 1.929 GB, free: 165.2 MB / 1.26 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.008147/5.041, allocations: 217 kB / 1.929 GB, free: 165.1 MB / 1.26 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.01266/5.053, allocations: 414.2 kB / 1.929 GB, free: 165 MB / 1.26 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.004011/5.057, allocations: 0.6527 MB / 1.93 GB, free: 164.9 MB / 1.26 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.002985/5.06, allocations: 403.9 kB / 1.93 GB, free: 164.8 MB / 1.26 GB Notification: Performance of sorting global known variables: time 0.02124/5.082, allocations: 8.965 MB / 1.939 GB, free: 161.8 MB / 1.26 GB Notification: Performance of sort global known variables: time 2.11e-07/5.082, allocations: 0 / 1.939 GB, free: 161.8 MB / 1.26 GB Notification: Performance of remove unused functions: time 0.01863/5.1, allocations: 4.643 MB / 1.944 GB, free: 160.9 MB / 1.26 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 91 * Number of states: 90 (airEle111.fluid.rho,airEle111.fluid.h,airEle211.fluid.rho,airEle211.fluid.h,flowConnectionX_111_112.v,west11.ori.mExc,west11.senTem.T,floor11.ori.mExc,floor11.senTem.T,north11.ori.mExc,north11.senTem.T,south11.ori.mExc,south11.senTem.T,floor21.ori.mExc,floor21.senTem.T,south21.ori.mExc,south21.senTem.T,north21.ori.mExc,north21.senTem.T,flowConnectionX_211_311.v,airEle311.fluid.rho,airEle311.fluid.h,east11.ori.mExc,east11.senTem.T,floor31.ori.mExc,floor31.senTem.T,north31.ori.mExc,north31.senTem.T,south31.ori.mExc,south31.senTem.T,airEle121.fluid.rho,airEle121.fluid.h,airEle221.fluid.rho,airEle221.fluid.h,flowConnectionX_121_221.v,west21.ori.mExc,west21.senTem.T,north12.ori.mExc,north12.senTem.T,south12.ori.mExc,south12.senTem.T,south22.ori.mExc,south22.senTem.T,west22.ori.mExc,west22.senTem.T,flowConnectionX_221_321.v,airEle321.fluid.rho,airEle321.fluid.h,east12.ori.mExc,east12.senTem.T,north32.ori.mExc,north32.senTem.T,south32.ori.mExc,south32.senTem.T,airEle131.fluid.rho,airEle131.fluid.h,airEle231.fluid.rho,airEle231.fluid.h,flowConnectionX_131_231.v,west31.ori.mExc,west31.senTem.T,roof11.ori.mExc,roof11.senTem.T,north13.ori.mExc,north13.senTem.T,south13.ori.mExc,south13.senTem.T,south23.ori.mExc,south23.senTem.T,roof21.ori.mExc,roof21.senTem.T,north23.ori.mExc,north23.senTem.T,flowConnectionX_231_331.v,airEle331.fluid.rho,airEle331.fluid.h,east13.ori.mExc,east13.senTem.T,roof31.ori.mExc,roof31.senTem.T,north33.ori.mExc,north33.senTem.T,south33.ori.mExc,south33.senTem.T,flowConnectionY_111_121.v,flowConnectionY_211_221.v,flowConnectionY_311_321.v,flowConnectionY_111_131.v,flowConnectionY_221_231.v,flowConnectionY_321_331.v) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (627): * Single equations (assignments): 579 * Array equations: 0 * Algorithm blocks: 18 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 30 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 30 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Performance of Backend phase and start with SimCode phase: time 0.03216/5.132, allocations: 20.38 MB / 1.963 GB, free: 146.6 MB / 1.26 GB Notification: Performance of simCode: created initialization part: time 0.0294/5.162, allocations: 16.22 MB / 1.979 GB, free: 131.4 MB / 1.26 GB Notification: Performance of simCode: created event and clocks part: time 4.82e-05/5.162, allocations: 11.8 kB / 1.979 GB, free: 131.4 MB / 1.26 GB Notification: Performance of simCode: created simulation system equations: time 0.01607/5.178, allocations: 7.915 MB / 1.987 GB, free: 124.1 MB / 1.26 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.02916/5.207, allocations: 4.32 MB / 1.991 GB, free: 120.7 MB / 1.26 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.305/5.512, allocations: 140 MB / 2.128 GB, free: 8.41 MB / 1.292 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.02051/5.533, allocations: 7.385 MB / 2.135 GB, free: 0.9922 MB / 1.292 GB Notification: Performance of simCode: alias equations: time 0.01359/5.546, allocations: 2.375 MB / 2.138 GB, free: 14.61 MB / 1.307 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01262/5.559, allocations: 7.495 MB / 2.145 GB, free: 7.117 MB / 1.307 GB Notification: Performance of SimCode: time 2.855e-06/5.559, allocations: 3.188 kB / 2.145 GB, free: 7.117 MB / 1.307 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 1.3/6.859, allocations: 356.9 MB / 2.493 GB, free: 204.9 MB / 1.385 GB Error: Error building simulator. Build log: cmd: cd '572.fmutmp/sources/' && mkdir build_cmake_static && cd build_cmake_static && cmake -DCMAKE_BUILD_TYPE=Release -DCMAKE_C_COMPILER='clang' .. && cmake --build . --parallel -j1 --target install && cd .. && rm -rf build_cmake_static -- The C compiler identification is Clang 18.1.3 -- Detecting C compiler ABI info -- Detecting C compiler ABI info - done -- Check for working C compiler: /usr/bin/clang - skipped -- Detecting C compile features -- Detecting C compile features - done -- FMI2 include directory: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/fmi -- Performing Test CMAKE_HAVE_LIBC_PTHREAD -- Performing Test CMAKE_HAVE_LIBC_PTHREAD - Success -- Found Threads: TRUE -- Building for FMI platform linux64 -- Install directory: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/../binaries/linux64 -- CVODE: Not linked -- Not using FMI2_FUNCTION_PREFIX -- Installing dynamic dependencies from list: -- Configuring done (0.2s) -- Generating done (0.0s) -- Build files have been written to: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/build_cmake_static [ 0%] Building C object CMakeFiles/572.dir/external_solvers/F77_aloc.c.o [ 1%] Building C object CMakeFiles/572.dir/external_solvers/dgemm.c.o [ 2%] Building C object CMakeFiles/572.dir/external_solvers/dgemv.c.o [ 3%] Building C object CMakeFiles/572.dir/external_solvers/dger.c.o [ 4%] Building C object CMakeFiles/572.dir/external_solvers/dgesv.c.o [ 4%] Building C object CMakeFiles/572.dir/external_solvers/dgetf2.c.o [ 5%] Building C object CMakeFiles/572.dir/external_solvers/dgetrf.c.o [ 6%] Building C object CMakeFiles/572.dir/external_solvers/dgetri.c.o [ 7%] Building C object CMakeFiles/572.dir/external_solvers/dgetrs.c.o [ 8%] Building C object CMakeFiles/572.dir/external_solvers/dlamch.c.o [ 8%] Building C object CMakeFiles/572.dir/external_solvers/dlaswp.c.o [ 9%] Building C object CMakeFiles/572.dir/external_solvers/dogleg_.c.o [ 10%] Building C object CMakeFiles/572.dir/external_solvers/dpmpar_.c.o [ 11%] Building C object CMakeFiles/572.dir/external_solvers/dscal.c.o [ 12%] Building C object CMakeFiles/572.dir/external_solvers/dswap.c.o [ 13%] Building C object CMakeFiles/572.dir/external_solvers/dtrmm.c.o [ 13%] Building C object CMakeFiles/572.dir/external_solvers/dtrmv.c.o [ 14%] Building C object CMakeFiles/572.dir/external_solvers/dtrsm.c.o [ 15%] Building C object CMakeFiles/572.dir/external_solvers/dtrti2.c.o [ 16%] Building C object CMakeFiles/572.dir/external_solvers/dtrtri.c.o [ 17%] Building C object CMakeFiles/572.dir/external_solvers/enorm_.c.o [ 17%] Building C object CMakeFiles/572.dir/external_solvers/exit_.c.o [ 18%] Building C object CMakeFiles/572.dir/external_solvers/hybrj_.c.o [ 19%] Building C object CMakeFiles/572.dir/external_solvers/i_nint.c.o [ 20%] Building C object CMakeFiles/572.dir/external_solvers/idamax.c.o [ 21%] Building C object CMakeFiles/572.dir/external_solvers/ieeeck.c.o [ 21%] Building C object CMakeFiles/572.dir/external_solvers/ilaenv.c.o [ 22%] Building C object CMakeFiles/572.dir/external_solvers/iparmq.c.o [ 23%] Building C object CMakeFiles/572.dir/external_solvers/lsame.c.o [ 24%] Building C object CMakeFiles/572.dir/external_solvers/pow_di.c.o [ 25%] Building C object CMakeFiles/572.dir/external_solvers/qform_.c.o [ 26%] Building C object CMakeFiles/572.dir/external_solvers/qrfac_.c.o [ 26%] Building C object CMakeFiles/572.dir/external_solvers/r1mpyq_.c.o [ 27%] Building C object CMakeFiles/572.dir/external_solvers/r1updt_.c.o [ 28%] Building C object CMakeFiles/572.dir/external_solvers/s_cat.c.o [ 29%] Building C object CMakeFiles/572.dir/external_solvers/s_cmp.c.o [ 30%] Building C object CMakeFiles/572.dir/external_solvers/s_copy.c.o [ 30%] Building C object CMakeFiles/572.dir/external_solvers/xerbla.c.o [ 31%] Building C object CMakeFiles/572.dir/fmi-export/fmu2_model_interface.c.o [ 32%] Building C object CMakeFiles/572.dir/fmi-export/fmu_read_flags.c.o [ 33%] Building C object CMakeFiles/572.dir/gc/memory_pool.c.o [ 34%] Building C object CMakeFiles/572.dir/gc/omc_gc.c.o [ 34%] Building C object CMakeFiles/572.dir/math-support/pivot.c.o [ 35%] Building C object CMakeFiles/572.dir/meta/meta_modelica_catch.c.o [ 36%] Building C object CMakeFiles/572.dir/simulation/arrayIndex.c.o [ 37%] Building C object CMakeFiles/572.dir/simulation/eval_dep.c.o [ 38%] Building C object CMakeFiles/572.dir/simulation/jacobian_util.c.o [ 39%] Building C object CMakeFiles/572.dir/simulation/omc_simulation_util.c.o [ 39%] Building C object CMakeFiles/572.dir/simulation/options.c.o [ 40%] Building C object CMakeFiles/572.dir/simulation/simulation_info_json.c.o [ 41%] Building C object CMakeFiles/572.dir/simulation/simulation_omc_assert.c.o [ 42%] Building C object CMakeFiles/572.dir/simulation/solver/delay.c.o [ 43%] Building C object CMakeFiles/572.dir/simulation/solver/discrete_changes.c.o [ 43%] Building C object CMakeFiles/572.dir/simulation/solver/initialization/initialization.c.o [ 44%] Building C object CMakeFiles/572.dir/simulation/solver/model_help.c.o [ 45%] Building C object CMakeFiles/572.dir/simulation/solver/nonlinearSolverHomotopy.c.o [ 46%] Building C object CMakeFiles/572.dir/simulation/solver/nonlinearSolverHybrd.c.o [ 47%] Building C object CMakeFiles/572.dir/simulation/solver/nonlinearSystem.c.o [ 47%] Building C object CMakeFiles/572.dir/simulation/solver/nonlinearValuesList.c.o [ 48%] Building C object CMakeFiles/572.dir/simulation/solver/omc_math.c.o [ 49%] Building C object CMakeFiles/572.dir/simulation/solver/spatialDistribution.c.o [ 50%] Building C object CMakeFiles/572.dir/simulation/solver/stateset.c.o [ 51%] Building C object CMakeFiles/572.dir/simulation/solver/synchronous.c.o [ 52%] Building C object CMakeFiles/572.dir/util/ModelicaUtilities.c.o [ 52%] Building C object CMakeFiles/572.dir/util/base_array.c.o [ 53%] Building C object CMakeFiles/572.dir/util/boolean_array.c.o [ 54%] Building C object CMakeFiles/572.dir/util/context.c.o [ 55%] Building C object CMakeFiles/572.dir/util/division.c.o [ 56%] Building C object CMakeFiles/572.dir/util/doubleEndedList.c.o [ 56%] Building C object CMakeFiles/572.dir/util/generic_array.c.o [ 57%] Building C object CMakeFiles/572.dir/util/index_spec.c.o [ 58%] Building C object CMakeFiles/572.dir/util/integer_array.c.o [ 59%] Building C object CMakeFiles/572.dir/util/list.c.o [ 60%] Building C object CMakeFiles/572.dir/util/modelica_string.c.o [ 60%] Building C object CMakeFiles/572.dir/util/modelica_string_lit.c.o [ 61%] Building C object CMakeFiles/572.dir/util/omc_error.c.o [ 62%] Building C object CMakeFiles/572.dir/util/omc_file.c.o [ 63%] Building C object CMakeFiles/572.dir/util/omc_init.c.o [ 64%] Building C object CMakeFiles/572.dir/util/omc_mmap.c.o [ 65%] Building C object CMakeFiles/572.dir/util/omc_msvc.c.o [ 65%] Building C object CMakeFiles/572.dir/util/omc_numbers.c.o [ 66%] Building C object CMakeFiles/572.dir/util/parallel_helper.c.o [ 67%] Building C object CMakeFiles/572.dir/util/rational.c.o [ 68%] Building C object CMakeFiles/572.dir/util/real_array.c.o [ 69%] Building C object CMakeFiles/572.dir/util/ringbuffer.c.o [ 69%] Building C object CMakeFiles/572.dir/util/simulation_options.c.o [ 70%] Building C object CMakeFiles/572.dir/util/string_array.c.o [ 71%] Building C object CMakeFiles/572.dir/util/utility.c.o [ 72%] Building C object CMakeFiles/572.dir/util/varinfo.c.o [ 73%] Building C object CMakeFiles/572.dir/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c.o /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4702:476: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4702 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4716:478: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4716 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4736:507: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4736 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[1] variable */) = (fmin(0.05,log(tmp21))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4752:480: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4752 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4787:509: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4787 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[202]] /* airEle111.vVec[1] variable */) = (fmin(0.05,log(tmp26))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[9]] /* airEle111.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dy * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4807:476: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4807 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[203]] /* airEle111.vVec[2] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[690]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4821:478: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4821 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[203]] /* airEle111.vVec[2] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[690]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4841:507: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4841 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[203]] /* airEle111.vVec[2] variable */) = (fmin(0.05,log(tmp30))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[690]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4857:480: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4857 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[203]] /* airEle111.vVec[2] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[690]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:4892:509: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 4892 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[203]] /* airEle111.vVec[2] variable */) = (fmin(0.05,log(tmp35))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[690]] /* flowConnectionY_111_121.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[8]] /* airEle111.dx PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[10]] /* airEle111.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[1]] /* airEle111.fluid.rho STATE(1) */))),\"airEle111.dx * airEle111.dz * inStream(airEle111.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5361:479: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5361 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5369:481: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5369 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[644]] /* flowConnectionX_211_311.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5377:611: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5377 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */) + (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[644]] /* flowConnectionX_211_311.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5394:481: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5394 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5402:483: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5402 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[644]] /* flowConnectionX_211_311.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5423:512: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5423 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = (fmin(0.05,log(tmp65))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[644]] /* flowConnectionX_211_311.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes)); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5440:483: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5440 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[644]] /* flowConnectionX_211_311.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5448:485: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5448 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes); | ^ /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Airvolumes.Examples.AirElementsThermal3x3x1/572.fmutmp/sources/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c:5469:514: error: call to undeclared function 'inStream'; ISO C99 and later do not support implicit function declarations [-Wimplicit-function-declaration] 5469 | (data->localData[0]->realVars[data->simulationInfo->realVarsIndex[277]] /* airEle211.vVec[1] variable */) = (fmin(0.05,log(tmp72))) * (DIVISION_SIM((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[596]] /* flowConnectionX_111_112.port_1.m_flow variable */),(((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[219]] /* airEle211.dy PARAM */)) * ((data->simulationInfo->realParameter[data->simulationInfo->realParamsIndex[220]] /* airEle211.dz PARAM */))) * (inStream((data->localData[0]->realVars[data->simulationInfo->realVarsIndex[7]] /* airEle211.fluid.rho STATE(1) */))),\"airEle211.dy * airEle211.dz * inStream(airEle211.fluid.rho)\",equationIndexes)); | ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. gmake[2]: *** [CMakeFiles/572.dir/build.make:1322: CMakeFiles/572.dir/BuildingSystems_BuildingSystems_Buildings_Airvolumes_Examples_AirElementsThermal3x3x1.c.o] Error 1 gmake[1]: *** [CMakeFiles/Makefile2:84: CMakeFiles/572.dir/all] Error 2 gmake: *** [Makefile:136: all] Error 2 " [Timeout remaining time 646] [Calling sys.exit(0), Time elapsed: 17.22376526426524] Failed to read output from testmodel.py, exit status != 0: 13.998955085873604 14.008207384 10.879971148 Calling exit ...