(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_selfDraining_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_selfDraining_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=40 --stepSize=0.016 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_selfDraining_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Undirected.Boundaries.Tests.Tank_selfDraining (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 40.000000 - tolerance : 1e-06 - stepSize : 0.016 info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_selfDraining_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Tank_selfDraining.acceleration.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryFore1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.boundaryRear1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.flowResistance3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.flowResistance4.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.flowResistance5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_selfDraining.flowResistance6.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Undirected/Boundaries/Internal/PartialTankUndirected.mo:244:3-244:48:writable] | | | | The following assertion has been violated at time 6.064000 | | | | ((tank.M > 0.0)) --> "Tanks might not become empty" error: [fmi2logger] [fmi2Error] Tank_selfDraining/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "Tank_selfDraining.root.Tank_selfDraining" error: [fmi2logger] [fmi2Error] Tank_selfDraining/logStatusError: Model error: Argument of log(u) was -179.278 should be > 0 error: [fmi2logger] [fmi2Error] Tank_selfDraining/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable tank.use_hstart Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 5 errors