(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.PumpConstant_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_PumpConstant_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_PumpConstant_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Tests.Processes.Adiabatic.PumpConstant (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((isothermalReference3.p_min >= 611.657 and isothermalReference3.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= isothermalReference3.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((incompressibleFluid3.p_min >= 611.657 and incompressibleFluid3.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= incompressibleFluid3.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fullMedium3.p_min >= 611.657 and fullMedium3.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= fullMedium3.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((isothermalReference2.p_min >= 611.657 and isothermalReference2.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= isothermalReference2.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((isothermalReference1.p_min >= 611.657 and isothermalReference1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= isothermalReference1.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((isothermalReference.p_min >= 611.657 and isothermalReference.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= isothermalReference.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((incompressibleFluid2.p_min >= 611.657 and incompressibleFluid2.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= incompressibleFluid2.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((incompressibleFluid1.p_min >= 611.657 and incompressibleFluid1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= incompressibleFluid1.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fullMedium2.p_min >= 611.657 and fullMedium2.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= fullMedium2.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fullMedium1.p_min >= 611.657 and fullMedium1.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= fullMedium1.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((incompressibleFluid.p_min >= 611.657 and incompressibleFluid.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= incompressibleFluid.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fullMedium.p_min >= 611.657 and fullMedium.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= fullMedium.p_min <= 1e8, has value: 100" error: [fmi2logger] [fmi2Error] PumpConstant/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Water/IF97_Utilities.mo:3022: IF97 medium function tsat called with too low pressure p = 0 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] PumpConstant/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_exitInitializationMode failed for FMU "PumpConstant.root.PumpConstant" error: [initialize] Initialization of system "PumpConstant.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 175, in _runFMU fmu.initialize() ~~~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 887, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error info: 0 warnings info: 4 errors