(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Examples.WaterHammer_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Examples_WaterHammer_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=25 --stepSize=0.025 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Examples_WaterHammer_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Examples.WaterHammer (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 25.000000 - tolerance : 1e-06 - stepSize : 0.025 info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Examples.WaterHammer_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable WaterHammer.checkValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm1.massFlowString will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm1.massFlowUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm1.pressureUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm1.temperatureString will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm1.temperatureUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm2.massFlowString will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm2.massFlowUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm2.pressureUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm2.temperatureString will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm2.temperatureUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm3.massFlowString will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm3.massFlowUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm3.pressureUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm3.temperatureString will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.multiSensor_Tpm3.temperatureUnit will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.reservoir.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.sink1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.sink1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.sink1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.splitterT2_1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.splitterT2_1.splitterN.instanceName will not be stored in the result file, because the signal type is not supported info: Variable WaterHammer.valveLinear.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Boundaries/Internal/PartialVolume.mo:114:3-114:138:writable] | | | | The following assertion has been violated at time 0.025000 | | | | ((checkValve.inlet.m_flow > reservoir.m_flow_assert)) --> "In "WaterHammer.reservoir": Negative mass flow rate at Volume inlet" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Boundaries/Internal/PartialVolume.mo:116:3-116:80:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((reservoir.M > 0.0)) --> "In "WaterHammer.reservoir": Negative mass inside the volume" error: [fmi2logger] [fmi2Error] WaterHammer/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "WaterHammer.root.WaterHammer" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Boundaries/Internal/PartialVolume.mo:116:3-116:80:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((reservoir.M > 0.0)) --> "In "WaterHammer.reservoir": Negative mass inside the volume" error: [fmi2logger] [fmi2Error] WaterHammer/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable valveLinear.invertInput Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 4 errors