(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_PowerSysPro_PowerSysPro_Examples_OneSourceOneLigneWithFault_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --mode=cs --timeout=240 --tolerance=1e-06 ../PowerSysPro_PowerSysPro_Examples_OneSourceOneLigneWithFault_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : PowerSysPro.Examples.OneSourceOneLigneWithFault (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.0004 info: Result file: PowerSysPro_PowerSysPro_Examples_OneSourceOneLigneWithFault_OMSimulator-cs-euler_res.mat (bufferSize=10) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.1.3/package.mo:230:9-230:152:writable] | | | | The following assertion has been violated at time 0.400000 | | | | ((lnFault.IA <= 100.0)) --> ">>> Current flowing the line is exceeding the maximum admissible current for OneSourceOneLigneWithFault.lnFault"