(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Modelica_trunk_Modelica.Electrical.Batteries.Examples.CCCV_Stack_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Modelica_trunk_Modelica_Electrical_Batteries_Examples_CCCV_Stack_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1200 --stepSize=0.1 --mode=cs --timeout=240 --tolerance=1e-06 ../Modelica_trunk_Modelica_Electrical_Batteries_Examples_CCCV_Stack_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Modelica.Electrical.Batteries.Examples.CCCV_Stack (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1200.000000 - tolerance : 1e-06 - stepSize : 0.1 info: Result file: ../Modelica_trunk_Modelica.Electrical.Batteries.Examples.CCCV_Stack_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter CCCV_Stack.stack.cell[1,1].cell.ocv_soc.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[1,2].cell.ocv_soc.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[2,1].cell.ocv_soc.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[2,2].cell.ocv_soc.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[3,1].cell.ocv_soc.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[3,2].cell.ocv_soc.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[1,1].cell.ocv_soc.fileName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[1,2].cell.ocv_soc.fileName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[2,1].cell.ocv_soc.fileName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[2,2].cell.ocv_soc.fileName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[3,1].cell.ocv_soc.fileName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[3,2].cell.ocv_soc.fileName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[1,1].cell.ocv_soc.tableName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[1,2].cell.ocv_soc.tableName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[2,1].cell.ocv_soc.tableName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[2,2].cell.ocv_soc.tableName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[3,1].cell.ocv_soc.tableName will not be stored in the result file, because the signal type is not supported info: Parameter CCCV_Stack.stack.cell[3,2].cell.ocv_soc.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/BaseClasses/BaseCellStack.mo:57:3-57:71:writable] | | | | The following assertion has been violated at time 679.700000 | | | | ((stack.cell[1,2].cell.limIntegrator.y < stack.cell[1,2].cell.cellData.SOCmax + stack.cell[1,2].cell.SOCtolerance)) --> "Battery overcharged!" error: [fmi2logger] [fmi2Error] CCCV_Stack/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "CCCV_Stack.root.CCCV_Stack" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/BaseClasses/BaseCellStack.mo:57:3-57:71:writable] | | | | The following assertion has been violated at time 679.700000 | | | | ((stack.cell[1,2].cell.limIntegrator.y < stack.cell[1,2].cell.cellData.SOCmax + stack.cell[1,2].cell.SOCtolerance)) --> "Battery overcharged!" error: [fmi2logger] [fmi2Error] CCCV_Stack/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable stackData.cellData[3,2].useLinearSOCDependency Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 4 errors