(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_IDEAS_dev_IDEAS_Fluid_HeatPumps_Calibration_ScrollWaterToWater_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=142 --stepSize=0.0568 --mode=cs --timeout=240 --tolerance=1e-06 ../IDEAS_dev_IDEAS_Fluid_HeatPumps_Calibration_ScrollWaterToWater_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : IDEAS.Fluid.HeatPumps.Calibration.ScrollWaterToWater (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 142.000000 - tolerance : 1e-06 - stepSize : 0.0568 LOG_STDOUT | info | ... loading "ManufacturerData" from "/tmp/tmp93kiho0k/ScrollWaterToWater-s38j1ti8/temp/0001_ScrollWaterToWater/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Resources/src/fluid/heatpumps/calibration/manufacturerData.txt" info: Result file: IDEAS_dev_IDEAS_Fluid_HeatPumps_Calibration_ScrollWaterToWater_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter ScrollWaterToWater.calDat.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ScrollWaterToWater.calDat.tableName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Media/Refrigerants/R410A/specificVolumeVap_pT.mo:24: Failed to converge in IDEAS.Media.Refrigerants.R410A.specificVolumeVap_pT error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "ScrollWaterToWater.root.ScrollWaterToWater" error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Media/Refrigerants/R410A/specificVolumeVap_pT.mo:24: Failed to converge in IDEAS.Media.Refrigerants.R410A.specificVolumeVap_pT error: [fmi2logger] [fmi2Error] ScrollWaterToWater/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sin2.verifyInputs Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 6 errors