Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Chemical_Chemical.Examples.OxygenInWater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0009587/0.0009587, allocations: 88.44 kB / 19.18 MB, free: 0.7344 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0009383/0.0009383, allocations: 169.9 kB / 22.46 MB, free: 2.102 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.958/0.958, allocations: 177.1 MB / 202.8 MB, free: 5.746 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/package.mo): time 0.09114/0.09114, allocations: 17.38 MB / 276.6 MB, free: 11.85 MB / 266.7 MB " [Timeout remaining time 180] Using package Chemical with version 2.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(Chemical.Examples.OxygenInWater,fileNamePrefix="Chemical_Chemical_Examples_OxygenInWater",fmuType="me_cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(Chemical.Examples.OxygenInWater,fileNamePrefix="Chemical_Chemical_Examples_OxygenInWater",fmuType="me_cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.443e-06/1.443e-06, allocations: 1.203 kB / 413 MB, free: 12.23 MB / 330.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.044e-05/2.188e-05, allocations: 6.812 kB / 413 MB, free: 12.23 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/Boundaries.mo:1328:7-1328:66:writable] Warning: An inner declaration for outer component system could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/Boundaries.mo:1328:7-1328:66:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"system\" component but an inner \"system\" component is not defined. For simulation drag Modelica.Fluid.System into your model to specify system properties. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/Boundaries.mo:1343:7-1343:76:writable] Warning: An inner declaration for outer component dropOfCommons could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/Boundaries.mo:1343:7-1343:76:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"dropOfCommons\" component but an inner \"dropOfCommons\" component is not defined. Use Chemical.DropOfCommons in your model to specify system properties. Notification: Performance of NFInst.instantiate(Chemical.Examples.OxygenInWater): time 0.05057/0.05059, allocations: 65.77 MB / 478.8 MB, free: 7.043 MB / 378.7 MB Notification: Performance of NFInst.instExpressions: time 0.339/0.3896, allocations: 136.7 MB / 0.601 GB, free: 24.3 MB / 490.7 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.006499/0.3961, allocations: 131.7 kB / 0.6012 GB, free: 24.3 MB / 490.7 MB Notification: Performance of NFTyping.typeComponents: time 0.005575/0.4016, allocations: 3.303 MB / 0.6044 GB, free: 24.21 MB / 490.7 MB Notification: Performance of NFTyping.typeBindings: time 0.008904/0.4105, allocations: 3.739 MB / 0.608 GB, free: 24.03 MB / 490.7 MB Notification: Performance of NFTyping.typeClassSections: time 0.008063/0.4186, allocations: 5.588 MB / 0.6135 GB, free: 23.75 MB / 490.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.0/Interfaces.mo:1317:3-1317:46:writable] Error: Parameter gasSolubilityR.nextProducts[1].data.MM has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.004412/0.423, allocations: 3.564 MB / 0.617 GB, free: 22.84 MB / 490.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.4022046765312552]