(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.Fluid.CHPs.BaseClasses.Validation.EnergyConversion_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_Fluid_CHPs_BaseClasses_Validation_EnergyConversion_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3000 --stepSize=1.2 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_Fluid_CHPs_BaseClasses_Validation_EnergyConversion_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.CHPs.BaseClasses.Validation.EnergyConversion (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3000.000000 - tolerance : 1e-06 - stepSize : 1.2 info: Result file: ../Buildings_latest_Buildings.Fluid.CHPs.BaseClasses.Validation.EnergyConversion_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter EnergyConversion.avaSig.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter EnergyConversion.avaSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter EnergyConversion.avaSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter EnergyConversion.runSig.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter EnergyConversion.runSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter EnergyConversion.runSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 363.600000 | | | | ((not eneConTimDel.assFue.hys.y)) --> "Rate of change in the fuel mass flow rate is outside boundaries!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 363.600000 | | | | ((not eneConEngTem.assFue.hys.y)) --> "Rate of change in the fuel mass flow rate is outside boundaries!" LOG_ASSERT | debug | division leads to inf or nan at time 541.2, (a=-7.72256e+306) / (b=0.01), where divisor b is: eneConEngTem.assFue.floChaRat.T error: [stepUntil] fmi2_doStep failed for FMU "EnergyConversion.root.EnergyConversion" LOG_ASSERT | debug | division leads to inf or nan at time 541.2, (a=-7.72256e+306) / (b=0.01), where divisor b is: eneConEngTem.assFue.floChaRat.T error: [fmi2logger] [fmi2Error] EnergyConversion/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable runSig.y Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors