(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Examples_Cooling_ElectricChillersDirectETS_OMSimulator-cs-euler_fmu --startTime=1.57248e+07 --stopTime=1.63296e+07 --stepSize=241.92 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Examples_Cooling_ElectricChillersDirectETS_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Examples.Cooling.ElectricChillersDirectETS (co-simulation) - fmiVersion: 2.0 - startTime : 15724800.000000 - stopTime : 16329600.000000 - tolerance : 1e-06 - stepSize : 241.92 warning: [fmi2Warning] ElectricChillersDirectETS/logStatusWarning: Returning path (/tmp/tmp6wusr61_/ElectricChillersDirectETS-oowxkw8j/temp/0001_ElectricChillersDirectETS/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp6wusr61_/ElectricChillersDirectETS-oowxkw8j/temp/0001_ElectricChillersDirectETS/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" warning: [fmi2Warning] ElectricChillersDirectETS/logStatusWarning: Returning path (/tmp/tmp6wusr61_/ElectricChillersDirectETS-oowxkw8j/temp/0001_ElectricChillersDirectETS/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp6wusr61_/ElectricChillersDirectETS-oowxkw8j/temp/0001_ElectricChillersDirectETS/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" warning: [fmi2Warning] ElectricChillersDirectETS/logStatusWarning: Returning path (/tmp/tmp6wusr61_/ElectricChillersDirectETS-oowxkw8j/temp/0001_ElectricChillersDirectETS/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp6wusr61_/ElectricChillersDirectETS-oowxkw8j/temp/0001_ElectricChillersDirectETS/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" warning: [fmi2Warning] ElectricChillersDirectETS/logStatusWarning: Returning path (/tmp/tmp6wusr61_/ElectricChillersDirectETS-oowxkw8j/temp/0001_ElectricChillersDirectETS/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 15724800.000000 | | | | ((pla.valByp.m_flow >= 0.0 and pla.valByp.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pla.valByp.m_flow <= 1e5, has value: -0.189856" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 15724800.000000 | | | | ((pla.pumCHW.pum[2].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumCHW.pum[2].etaHyd, has value: -5.40691e-22" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 15724800.000000 | | | | ((pla.pumCHW.pum[1].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumCHW.pum[1].etaHyd, has value: -5.40691e-22" info: Result file: Buildings_13_Buildings_DHC_Examples_Cooling_ElectricChillersDirectETS_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable ElectricChillersDirectETS.buiETS[1].bui.filNam will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[2].bui.filNam will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[3].bui.filNam will not be stored in the result file, because the signal type is not supported info: Parameter ElectricChillersDirectETS.buiETS[1].bui.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ElectricChillersDirectETS.buiETS[2].bui.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ElectricChillersDirectETS.buiETS[3].bui.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[1].bui.loa.fileName will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[2].bui.loa.fileName will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[3].bui.loa.fileName will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[1].bui.loa.tableName will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[2].bui.loa.tableName will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.buiETS[3].bui.loa.tableName will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.filNam[1] will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.filNam[2] will not be stored in the result file, because the signal type is not supported info: Variable ElectricChillersDirectETS.filNam[3] will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 15725041.920000 | | | | ((noEvent(dis.con[1].pipDisSup.vol_b.dynBal.medium.T >= 272.15))) --> "In ElectricChillersDirectETS.dis.con[1].pipDisSup.vol_b.dynBal.medium: Temperature T = 260.249 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] ElectricChillersDirectETS/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "ElectricChillersDirectETS.root.ElectricChillersDirectETS" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 15725041.920000 | | | | ((noEvent(dis.con[2].pipDisRet.vol_b.dynBal.medium.T >= 272.15))) --> "In ElectricChillersDirectETS.dis.con[2].pipDisRet.vol_b.dynBal.medium: Temperature T = 266.445 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] ElectricChillersDirectETS/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable tim.u Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 4 warnings info: 4 errors