(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones3_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones3_OMSimulator-cs-euler.fmu)
info: *** FMU Simulation Info ***
- model : Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones3 (co-simulation)
- fmiVersion: 2.0
- startTime : 0.000000
- stopTime : 3600.000000
- tolerance : 1e-06
- stepSize : 1.44
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Using pre-compiled FMU /tmp/tmppyv30q51/FMUZoneAdapterZones3-913i3v7t/temp/0001_FMUZoneAdapterZones3/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones3.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable North_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones3/run_OMSimulator-cs-euler/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones3/run_OMSimulator-cs-euler/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones3/run_OMSimulator-cs-euler/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
info: Result file: Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones3_OMSimulator-cs-euler_res.mat (bufferSize=10)
info: Variable FMUZoneAdapterZones3.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonNor.epwName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonNor.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonNor.idfName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonNor.zoneName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonSou.epwName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonSou.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonSou.idfName will not be stored in the result file, because the signal type is not supported
info: Variable FMUZoneAdapterZones3.fmuZonSou.zoneName will not be stored in the result file, because the signal type is not supported
LOG_STDOUT | info | 60.480 FMUZoneAdapterZones3.building: Error from EnergyPlus: Current time 6.0480000000000004E+01 is after next time event 6.0000000000000000E+01. Consider to change option 2.2204460492503131E-14.
LOG_ASSERT | debug | 60.480 FMUZoneAdapterZones3.fmuZonNor: Failed to enter event mode in SpawnUtil.c, returned status is Error.
error: [fmi2logger] [fmi2Error] FMUZoneAdapterZones3/logFmi2Call: internalEventUpdate: terminated by an assertion.
error: [stepUntil] fmi2_doStep failed for FMU "FMUZoneAdapterZones3.root.FMUZoneAdapterZones3"
Traceback (most recent call last):
File "", line 198, in _run_module_as_main
File "", line 88, in _run_code
File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in
sys.exit(main())
~~~~^^
File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main
handler(args.model, args)
~~~~~~~^^^^^^^^^^^^^^^^^^
File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU
fmu.simulate()
~~~~~~~~~~~~^^
File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate
raise RuntimeError(f"Failed to simulate model: {status}")
RuntimeError: Failed to simulate model: Status.error
info: 0 warnings
info: 2 errors