(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Fluid_Movers_PumpsPolynomialBased_Examples_PumpSpeedControlledDpV_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=600 --stepSize=0.24 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Fluid_Movers_PumpsPolynomialBased_Examples_PumpSpeedControlledDpV_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Fluid.Movers.PumpsPolynomialBased.Examples.PumpSpeedControlledDpV (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 600.000000 - tolerance : 1e-06 - stepSize : 0.24 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/PumpsPolynomialBased/PumpSpeedControlled.mo:298:3-302:29:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ctrlDpVarN.pumpBus.vFRcur_m3h >= 0.0 and ctrlDpVarN.pumpBus.vFRcur_m3h <= max(pump.pumpParam.maxMinSpeedCurves[:,1]))) --> "Variable violating min/max constraint: 0.0 <= ctrlDpVarN.pumpBus.vFRcur_m3h <= max(pump.pumpParam.maxMinSpeedCurves[:,1]), has value: 16.0298" info: Result file: AixLib_AixLib_Fluid_Movers_PumpsPolynomialBased_Examples_PumpSpeedControlledDpV_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter PumpSpeedControlledDpV.pump.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PumpSpeedControlledDpV.pump.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PumpSpeedControlledDpV.pump.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | division leads to inf or nan at time 22.08, (a=-3.60805e+307) / (b=0.0001), where divisor b is: ctrlDpVarN.PID.D.T error: [stepUntil] fmi2_doStep failed for FMU "PumpSpeedControlledDpV.root.PumpSpeedControlledDpV" LOG_ASSERT | debug | division leads to inf or nan at time 22.08, (a=-3.60805e+307) / (b=0.0001), where divisor b is: ctrlDpVarN.PID.D.T error: [fmi2logger] [fmi2Error] PumpSpeedControlledDpV/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pumpBus.onSet Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors