Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Examples.Gas.GasGrid_StandAlone.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0006425/0.0006425, allocations: 28.61 kB / 22.96 MB, free: 1.602 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo): time 0.5622/0.5622, allocations: 100.7 MB / 126.7 MB, free: 288 kB / 106.8 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo): time 0.06172/0.06172, allocations: 16.06 MB / 173.7 MB, free: 2.078 MB / 154.8 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001039/0.001039, allocations: 88.2 kB / 211 MB, free: 14.62 MB / 170.8 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001315/0.001315, allocations: 167.2 kB / 248.3 MB, free: 9.254 MB / 202.8 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.8851/0.8851, allocations: 177.1 MB / 462.7 MB, free: 3.941 MB / 330.8 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo): time 1.692/1.692, allocations: 376.9 MB / 0.9083 GB, free: 8.672 MB / 0.7293 GB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/package.mo:2:1-91:12:writable] Warning: The package.order file contains a class FluidPortOut_simple, which is expected to be stored in file FluidPortOut_simple.mo, but seems to be named fluidPortOut_simple.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/package.mo:2:1-91:12:writable] Warning: The package.order file contains a class FluidPortIn_simple, which is expected to be stored in file FluidPortIn_simple.mo, but seems to be named fluidPortIn_simple.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/fluidPortOut_simple.mo:2:1-49:24:writable] Warning: Expected the package to have name fluidPortOut_simple, but got FluidPortOut_simple. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/fluidPortIn_simple.mo:2:1-50:23:writable] Warning: Expected the package to have name fluidPortIn_simple, but got FluidPortIn_simple. Proceeding since only the case of the names are different. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo): time 1.012/1.012, allocations: 241.6 MB / 1.352 GB, free: 6.293 MB / 1.151 GB " [Timeout remaining time 178] Using package TransiEnt with version 2.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo) Using package Buildings with version 12.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(TransiEnt.Examples.Gas.GasGrid_StandAlone,fileNamePrefix="TransiEnt_TransiEnt_Examples_Gas_GasGrid_StandAlone",fmuType="me_cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(TransiEnt.Examples.Gas.GasGrid_StandAlone,fileNamePrefix="TransiEnt_TransiEnt_Examples_Gas_GasGrid_StandAlone",fmuType="me_cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 4.228e-06/4.228e-06, allocations: 4 kB / 1.923 GB, free: 10.44 MB / 1.433 GB Notification: Performance of FrontEnd - Absyn->SCode: time 1.164e-05/1.587e-05, allocations: 2.281 kB / 1.923 GB, free: 10.43 MB / 1.433 GB Notification: Performance of NFInst.instantiate(TransiEnt.Examples.Gas.GasGrid_StandAlone): time 0.05937/0.05939, allocations: 91.15 MB / 2.012 GB, free: 14.94 MB / 1.526 GB Notification: Performance of NFInst.instExpressions: time 1.419/1.478, allocations: 50.68 MB / 2.061 GB, free: 25.34 MB / 1.558 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02634/1.504, allocations: 0.6926 MB / 2.062 GB, free: 25.34 MB / 1.558 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Source_yellow_T.mo:47:3-57:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Sink_yellow.mo:41:3-47:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Split.mo:45:3-51:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Split.mo:52:3-62:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Split.mo:63:3-73:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:54:3-60:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:61:3-71:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:54:3-60:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:61:3-71:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:54:3-60:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:61:3-71:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:54:3-60:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:61:3-71:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Split.mo:45:3-51:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Split.mo:52:3-62:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Split.mo:63:3-73:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:46:3-52:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:53:3-62:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer1.mo:52:3-59:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer1.mo:60:3-66:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer1.mo:67:3-76:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer1.mo:52:3-59:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer1.mo:60:3-66:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer1.mo:67:3-76:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:46:3-52:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:53:3-62:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Source_blue.mo:44:3-54:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer2.mo:51:3-61:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer2.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer2.mo:69:3-75:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Source_blue.mo:44:3-54:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer2.mo:51:3-61:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer2.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Mixer2.mo:69:3-75:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:45:3-51:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:52:3-62:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:45:3-51:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:52:3-62:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:83:3-83:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:84:3-84:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:85:3-85:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:86:3-86:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:87:3-87:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:88:3-88:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:90:3-90:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:91:3-91:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:93:3-93:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:96:3-96:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:98:3-98:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:101:3-101:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:103:3-103:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:65:3-65:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:120:3-120:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:65:3-65:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:120:3-120:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.02473/1.529, allocations: 10.55 MB / 2.072 GB, free: 25.1 MB / 1.558 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/VLEFluidFunctions.mo:524:13-528:28:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.specificEnthalpy_pTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.specificEnthalpy_pTxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/VLEFluidFunctions.mo:177:13-181:19:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.density_phxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.density_phxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/VLEFluidFunctions.mo:187:13-191:23:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.temperature_phxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.temperature_phxi'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Functions/fullPathName.mo:2:1-76:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Blocks/FirstOrder.mo:39:14-39:82:writable] Warning: In relation feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDInput.Tau == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Blocks/FirstOrder.mo:39:14-39:82:writable] Warning: In relation feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput.Tau == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Blocks/FirstOrder.mo:39:14-39:82:writable] Warning: In relation feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput1.Tau == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Blocks/FirstOrder.mo:39:14-39:82:writable] Warning: In relation feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDInput.Tau == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Blocks/FirstOrder.mo:39:14-39:82:writable] Warning: In relation feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput.Tau == 0.0, == on Real operands is deprecated in non-function contexts. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Blocks/FirstOrder.mo:39:14-39:82:writable] Warning: In relation feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput1.Tau == 0.0, == on Real operands is deprecated in non-function contexts. Notification: Performance of NFTyping.typeBindings: time 0.04373/1.573, allocations: 16.9 MB / 2.089 GB, free: 22.05 MB / 1.558 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Functions/GasProperties/verboseXi.mo:2:1-91:14:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.verboseXi' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: feedInStation1.electrolyzer.typeOfResource as Integer: CAST(Integer, feedInStation1.electrolyzer.typeOfResource). This is non-standard Modelica, use Integer(feedInStation1.electrolyzer.typeOfResource) instead! Warning: Allowing usage of enumeration expression: feedInStation2.electrolyzer.typeOfResource as Integer: CAST(Integer, feedInStation2.electrolyzer.typeOfResource). This is non-standard Modelica, use Integer(feedInStation2.electrolyzer.typeOfResource) instead! Notification: Performance of NFTyping.typeClassSections: time 0.0352/1.608, allocations: 16.58 MB / 2.105 GB, free: 21.42 MB / 1.558 GB Notification: Performance of NFFlatten.flatten: time 0.07517/1.683, allocations: 56.97 MB / 2.161 GB, free: 15.84 MB / 1.573 GB Notification: Performance of NFFlatten.resolveConnections: time 0.03883/1.722, allocations: 22.07 MB / 2.182 GB, free: 1.586 MB / 1.573 GB Notification: Performance of NFEvalConstants.evaluate: time 0.0664/1.788, allocations: 32.65 MB / 2.214 GB, free: 14.6 MB / 1.605 GB Notification: Performance of NFSimplifyModel.simplify: time 0.04064/1.829, allocations: 30.76 MB / 2.244 GB, free: 9.605 MB / 1.62 GB Notification: Performance of NFPackage.collectConstants: time 0.02416/1.853, allocations: 7.055 MB / 2.251 GB, free: 2.551 MB / 1.62 GB Notification: Performance of NFFlatten.collectFunctions: time 0.03175/1.885, allocations: 8.812 MB / 2.26 GB, free: 9.902 MB / 1.636 GB Notification: Performance of NFScalarize.scalarize: time 0.04219/1.927, allocations: 34.18 MB / 2.293 GB, free: 8.559 MB / 1.667 GB Notification: Performance of NFVerifyModel.verify: time 0.06116/1.988, allocations: 24.99 MB / 2.317 GB, free: 152 kB / 1.683 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:77:53-77:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:81:53-81:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:40:70-40:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/ModelStatistics.mo:103:71-103:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.1662/2.155, allocations: 150.3 MB / 2.464 GB, free: 2.121 MB / 1.823 GB Notification: Performance of FrontEnd - DAE generated: time 1.188e-05/2.155, allocations: 3.984 kB / 2.464 GB, free: 2.117 MB / 1.823 GB Notification: Performance of FrontEnd: time 2.925e-06/2.155, allocations: 0 / 2.464 GB, free: 2.117 MB / 1.823 GB Notification: Performance of Transformations before backend: time 0.005141/2.16, allocations: 0 / 2.464 GB, free: 2.117 MB / 1.823 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 9864 * Number of variables: 9864 Notification: Performance of Generate backend data structure: time 0.2087/2.368, allocations: 83.77 MB / 2.546 GB, free: 14.54 MB / 1.917 GB Notification: Performance of prepare preOptimizeDAE: time 4.827e-05/2.368, allocations: 20.02 kB / 2.546 GB, free: 14.52 MB / 1.917 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.01874/2.387, allocations: 4.606 MB / 2.55 GB, free: 9.953 MB / 1.917 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.03007/2.417, allocations: 7.554 MB / 2.558 GB, free: 2.352 MB / 1.917 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.1384/2.556, allocations: 78.2 MB / 2.634 GB, free: 4.941 MB / 1.995 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.001815/2.557, allocations: 1.996 MB / 2.636 GB, free: 2.93 MB / 1.995 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01222/2.57, allocations: 2.345 MB / 2.638 GB, free: 0.6328 MB / 1.995 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.1179/2.688, allocations: 110.4 MB / 2.746 GB, free: 3.18 MB / 2.12 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0006887/2.688, allocations: 206.1 kB / 2.747 GB, free: 2.977 MB / 2.12 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.009824/2.698, allocations: 1.213 MB / 2.748 GB, free: 1.812 MB / 2.12 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.002721/2.701, allocations: 3.477 MB / 2.751 GB, free: 14.34 MB / 2.136 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.1276/2.828, allocations: 81.34 MB / 2.831 GB, free: 12.93 MB / 2.214 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 1.404/4.232, allocations: 294.9 MB / 3.118 GB, free: 0.4999 GB / 2.277 GB Notification: Performance of preOpt comSubExp (simulation): time 0.05054/4.283, allocations: 42.74 MB / 3.16 GB, free: 492.9 MB / 2.277 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.04264/4.325, allocations: 38.03 MB / 3.197 GB, free: 476.6 MB / 2.277 GB Notification: Performance of preOpt evalFunc (simulation): time 0.1807/4.506, allocations: 111.4 MB / 3.306 GB, free: 397.6 MB / 2.277 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.05058/4.556, allocations: 43.81 MB / 3.349 GB, free: 352.9 MB / 2.277 GB Notification: Performance of preOpt simplifyInStream (simulation): time 0.02126/4.578, allocations: 4.346 MB / 3.353 GB, free: 350.7 MB / 2.277 GB Notification: Performance of pre-optimization done (n=5012): time 8.62e-05/4.578, allocations: 2.688 kB / 3.353 GB, free: 350.7 MB / 2.277 GB Notification: Performance of matching and sorting (n=5048): time 3.852/8.43, allocations: 1.8 GB / 5.153 GB, free: 425.2 MB / 2.402 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0009406/8.431, allocations: 6.271 MB / 5.159 GB, free: 417.5 MB / 2.402 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.1005/8.531, allocations: 55.14 MB / 5.213 GB, free: 372.3 MB / 2.402 GB Notification: Performance of collectPreVariables (initialization): time 0.008453/8.54, allocations: 0.4932 MB / 5.213 GB, free: 371.8 MB / 2.402 GB Notification: Performance of collectInitialEqns (initialization): time 0.0236/8.563, allocations: 26.8 MB / 5.239 GB, free: 347.8 MB / 2.402 GB Notification: Performance of collectInitialBindings (initialization): time 0.01869/8.582, allocations: 17.52 MB / 5.256 GB, free: 331.9 MB / 2.402 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.03277/8.615, allocations: 9.92 MB / 5.266 GB, free: 323 MB / 2.402 GB Notification: Performance of setup shared object (initialization): time 3.516e-05/8.615, allocations: 301.1 kB / 5.266 GB, free: 322.7 MB / 2.402 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.05036/8.665, allocations: 40.62 MB / 5.306 GB, free: 288 MB / 2.402 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.0572/8.722, allocations: 51.15 MB / 5.356 GB, free: 235.2 MB / 2.402 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID (0.0 = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP (0.0 = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID (0.0 = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP (0.0 = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.W_el_demand = $START.feedInStation2.electrolyzer.collectCosts.W_el_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.W_el_demand = $START.feedInStation1.electrolyzer.collectCosts.W_el_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand (0.0 = $START.pipe4.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue (0.0 = $START.pipe4.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand (0.0 = $START.pipe4.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue (0.0 = $START.pipe4.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand (0.0 = $START.pipe4.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue (0.0 = $START.pipe4.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand (0.0 = $START.pipe4.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue (0.0 = $START.pipe4.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand (0.0 = $START.pipe3.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue (0.0 = $START.pipe3.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand (0.0 = $START.pipe3.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue (0.0 = $START.pipe3.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand (0.0 = $START.pipe3.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue (0.0 = $START.pipe3.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand (0.0 = $START.pipe3.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue (0.0 = $START.pipe3.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand (0.0 = $START.pipe2.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue (0.0 = $START.pipe2.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand (0.0 = $START.pipe2.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue (0.0 = $START.pipe2.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand (0.0 = $START.pipe2.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue (0.0 = $START.pipe2.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand (0.0 = $START.pipe2.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue (0.0 = $START.pipe2.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand (0.0 = $START.pipe1.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue (0.0 = $START.pipe1.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand (0.0 = $START.pipe1.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue (0.0 = $START.pipe1.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand (0.0 = $START.pipe1.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue (0.0 = $START.pipe1.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand (0.0 = $START.pipe1.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue (0.0 = $START.pipe1.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.other_demand = $START.feedInStation2.electrolyzer.collectCosts.other_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.other_revenue = $START.feedInStation2.electrolyzer.collectCosts.other_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.H_demand = $START.feedInStation2.electrolyzer.collectCosts.H_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.H_revenue = $START.feedInStation2.electrolyzer.collectCosts.H_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.Q_demand = $START.feedInStation2.electrolyzer.collectCosts.Q_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.Q_revenue = $START.feedInStation2.electrolyzer.collectCosts.Q_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation2.electrolyzer.collectCosts.W_el_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.other_demand = $START.feedInStation1.electrolyzer.collectCosts.other_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.other_revenue = $START.feedInStation1.electrolyzer.collectCosts.other_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.H_demand = $START.feedInStation1.electrolyzer.collectCosts.H_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.H_revenue = $START.feedInStation1.electrolyzer.collectCosts.H_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.Q_demand = $START.feedInStation1.electrolyzer.collectCosts.Q_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.Q_revenue = $START.feedInStation1.electrolyzer.collectCosts.Q_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation1.electrolyzer.collectCosts.W_el_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.mass_H2 = $START.feedInStation2.electrolyzer.mass_H2 (0.0 = $START.feedInStation2.electrolyzer.mass_H2) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.mass_H2 = $START.feedInStation1.electrolyzer.mass_H2 (0.0 = $START.feedInStation1.electrolyzer.mass_H2) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed (0.0 = $START.pipe4.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced (0.0 = $START.pipe4.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed (0.0 = $START.pipe3.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced (0.0 = $START.pipe3.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed (0.0 = $START.pipe2.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced (0.0 = $START.pipe2.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed (0.0 = $START.pipe1.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced (0.0 = $START.pipe1.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_consumed (0.0 = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_produced (0.0 = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectElectricPower.E = $START.feedInStation2.electrolyzer.collectElectricPower.E (0.0 = $START.feedInStation2.electrolyzer.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_consumed (0.0 = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_produced (0.0 = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectElectricPower.E = $START.feedInStation1.electrolyzer.collectElectricPower.E (0.0 = $START.feedInStation1.electrolyzer.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Notification: Performance of analyzeInitialSystem (initialization): time 1.371/10.09, allocations: 354.9 MB / 5.703 GB, free: 0.695 GB / 2.402 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0005374/10.09, allocations: 104 kB / 5.703 GB, free: 0.695 GB / 2.402 GB Notification: Performance of matching and sorting (n=7639) (initialization): time 0.1628/10.26, allocations: 99.47 MB / 5.8 GB, free: 0.6403 GB / 2.402 GB Notification: Performance of prepare postOptimizeDAE: time 0.000468/10.26, allocations: 312.5 kB / 5.8 GB, free: 0.64 GB / 2.402 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.00434/10.26, allocations: 1.279 MB / 5.801 GB, free: 0.6388 GB / 2.402 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.008275/10.27, allocations: 3.517 MB / 5.805 GB, free: 0.6352 GB / 2.402 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.04334/10.31, allocations: 10.46 MB / 5.815 GB, free: 0.625 GB / 2.402 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.03054/10.34, allocations: 68.68 MB / 5.882 GB, free: 0.5546 GB / 2.402 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.03725/10.38, allocations: 1.842 MB / 5.884 GB, free: 0.5528 GB / 2.402 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01203/10.39, allocations: 2.234 MB / 5.886 GB, free: 0.5506 GB / 2.402 GB Warning: Assuming fixed start value for the following 64 variables: gasDemandProfiler.gasDemand_tot:VARIABLE(fixed = true ) \"Integrated gas demand in defined output\" type: Real gasDemandProfiler.gasDemand_base:VARIABLE(fixed = true ) \"Integrated base gas demand in defined output\" type: Real gasDemandProfiler.gasDemand_heat:VARIABLE(fixed = true ) \"Integrated heat gas demand in defined output\" type: Real gasDemandProfiler.Q_heatCharline:VARIABLE(unit = \"J\" fixed = true protected = true ) type: Real gasDemandProfiler.Q_heat:VARIABLE(unit = \"J\" fixed = true protected = true ) type: Real gasDemandProfiler.heatingLoadCharline.Q_dem:VARIABLE(unit = \"J\" fixed = true ) type: Real feedInStation1.controlTotalEly.controlElyOverload.state:DISCRETE(start = feedInStation1.controlTotalEly.startState fixed = true ) \"Defines the state the electrolyser is in (1: ready to overheat, 2: working in overload, 3: cooling down)\" type: Integer feedInStation1.controlTotalEly.controlElyOverload.overloadLevel:VARIABLE(start = 0.0 fixed = true ) \"Level of overheating\" type: Real feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y:VARIABLE(flow=false start = feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y_start_const fixed = true ) \"Connector of Real output signal\" type: Real feedInStation2.controlTotalEly.controlElyOverload.state:DISCRETE(start = feedInStation2.controlTotalEly.startState fixed = true ) \"Defines the state the electrolyser is in (1: ready to overheat, 2: working in overload, 3: cooling down)\" type: Integer feedInStation2.controlTotalEly.controlElyOverload.overloadLevel:VARIABLE(start = 0.0 fixed = true ) \"Level of overheating\" type: Real feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y:VARIABLE(flow=false start = feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y_start_const fixed = true ) \"Connector of Real output signal\" type: Real junction1.h:VARIABLE(start = init.junction1.h_in unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction1.p:VARIABLE(min = 0.0 start = init.junction1.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real pipe1.h[1]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[2]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[3]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[4]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[5]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.p[1]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[2]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[3]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[4]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[5]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.h[1]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[2]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[3]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[4]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[5]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.p[1]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[2]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[3]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[4]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[5]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.h[1]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[2]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[3]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[4]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[5]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.p[1]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[2]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[3]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[4]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[5]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.h[1]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[2]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[3]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[4]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[5]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.p[1]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[2]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[3]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[4]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[5]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] junction2.h:VARIABLE(start = init.junction2.h_out unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction2.p:VARIABLE(min = 0.0 start = init.junction2.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction3.h:VARIABLE(start = init.junction3.h_in unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction3.p:VARIABLE(min = 0.0 start = init.junction3.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction4.h:VARIABLE(start = init.junction4.h_out unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction4.p:VARIABLE(min = 0.0 start = init.junction4.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction_feedIn1.h:VARIABLE(start = init.junction1.h_in unit = \"J/kg\" fixed = true ) \"Specific enthalpy\" type: Real junction_feedIn1.p:VARIABLE(min = 0.0 start = init.junction1.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction_feedIn2.h:VARIABLE(start = init.junction1.h_in unit = \"J/kg\" fixed = true ) \"Specific enthalpy\" type: Real junction_feedIn2.p:VARIABLE(min = 0.0 start = init.junction1.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real Warning: The initial conditions are over specified. The following 130 initial equations are redundant, so they are removed from the initialization system: feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP feedInStation2.electrolyzer.collectCosts.W_el_demand = $START.feedInStation2.electrolyzer.collectCosts.W_el_demand feedInStation1.electrolyzer.collectCosts.W_el_demand = $START.feedInStation1.electrolyzer.collectCosts.W_el_demand pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue feedInStation2.electrolyzer.collectCosts.other_demand = $START.feedInStation2.electrolyzer.collectCosts.other_demand feedInStation2.electrolyzer.collectCosts.other_revenue = $START.feedInStation2.electrolyzer.collectCosts.other_revenue feedInStation2.electrolyzer.collectCosts.H_demand = $START.feedInStation2.electrolyzer.collectCosts.H_demand feedInStation2.electrolyzer.collectCosts.H_revenue = $START.feedInStation2.electrolyzer.collectCosts.H_revenue feedInStation2.electrolyzer.collectCosts.Q_demand = $START.feedInStation2.electrolyzer.collectCosts.Q_demand feedInStation2.electrolyzer.collectCosts.Q_revenue = $START.feedInStation2.electrolyzer.collectCosts.Q_revenue feedInStation2.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation2.electrolyzer.collectCosts.W_el_revenue feedInStation1.electrolyzer.collectCosts.other_demand = $START.feedInStation1.electrolyzer.collectCosts.other_demand feedInStation1.electrolyzer.collectCosts.other_revenue = $START.feedInStation1.electrolyzer.collectCosts.other_revenue feedInStation1.electrolyzer.collectCosts.H_demand = $START.feedInStation1.electrolyzer.collectCosts.H_demand feedInStation1.electrolyzer.collectCosts.H_revenue = $START.feedInStation1.electrolyzer.collectCosts.H_revenue feedInStation1.electrolyzer.collectCosts.Q_demand = $START.feedInStation1.electrolyzer.collectCosts.Q_demand feedInStation1.electrolyzer.collectCosts.Q_revenue = $START.feedInStation1.electrolyzer.collectCosts.Q_revenue feedInStation1.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation1.electrolyzer.collectCosts.W_el_revenue feedInStation2.electrolyzer.mass_H2 = $START.feedInStation2.electrolyzer.mass_H2 feedInStation1.electrolyzer.mass_H2 = $START.feedInStation1.electrolyzer.mass_H2 modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced feedInStation2.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_consumed feedInStation2.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_produced feedInStation2.electrolyzer.collectElectricPower.E = $START.feedInStation2.electrolyzer.collectElectricPower.E feedInStation1.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_consumed feedInStation1.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_produced feedInStation1.electrolyzer.collectElectricPower.E = $START.feedInStation1.electrolyzer.collectElectricPower.E modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg. Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.08649/10.48, allocations: 58.13 MB / 5.943 GB, free: 0.4938 GB / 2.402 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.0547/10.53, allocations: 51.09 MB / 5.993 GB, free: 449.2 MB / 2.402 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID (0.0 = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP (0.0 = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID (0.0 = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP (0.0 = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.W_el_demand = $START.feedInStation2.electrolyzer.collectCosts.W_el_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.W_el_demand = $START.feedInStation1.electrolyzer.collectCosts.W_el_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand (0.0 = $START.pipe4.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue (0.0 = $START.pipe4.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand (0.0 = $START.pipe4.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue (0.0 = $START.pipe4.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand (0.0 = $START.pipe4.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue (0.0 = $START.pipe4.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand (0.0 = $START.pipe4.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue (0.0 = $START.pipe4.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand (0.0 = $START.pipe3.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue (0.0 = $START.pipe3.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand (0.0 = $START.pipe3.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue (0.0 = $START.pipe3.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand (0.0 = $START.pipe3.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue (0.0 = $START.pipe3.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand (0.0 = $START.pipe3.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue (0.0 = $START.pipe3.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand (0.0 = $START.pipe2.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue (0.0 = $START.pipe2.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand (0.0 = $START.pipe2.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue (0.0 = $START.pipe2.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand (0.0 = $START.pipe2.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue (0.0 = $START.pipe2.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand (0.0 = $START.pipe2.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue (0.0 = $START.pipe2.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand (0.0 = $START.pipe1.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue (0.0 = $START.pipe1.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand (0.0 = $START.pipe1.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue (0.0 = $START.pipe1.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand (0.0 = $START.pipe1.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue (0.0 = $START.pipe1.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand (0.0 = $START.pipe1.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue (0.0 = $START.pipe1.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.other_demand = $START.feedInStation2.electrolyzer.collectCosts.other_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.other_revenue = $START.feedInStation2.electrolyzer.collectCosts.other_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.H_demand = $START.feedInStation2.electrolyzer.collectCosts.H_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.H_revenue = $START.feedInStation2.electrolyzer.collectCosts.H_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.Q_demand = $START.feedInStation2.electrolyzer.collectCosts.Q_demand (0.0 = $START.feedInStation2.electrolyzer.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.Q_revenue = $START.feedInStation2.electrolyzer.collectCosts.Q_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation2.electrolyzer.collectCosts.W_el_revenue (0.0 = $START.feedInStation2.electrolyzer.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.other_demand = $START.feedInStation1.electrolyzer.collectCosts.other_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.other_revenue = $START.feedInStation1.electrolyzer.collectCosts.other_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.H_demand = $START.feedInStation1.electrolyzer.collectCosts.H_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.H_revenue = $START.feedInStation1.electrolyzer.collectCosts.H_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.Q_demand = $START.feedInStation1.electrolyzer.collectCosts.Q_demand (0.0 = $START.feedInStation1.electrolyzer.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.Q_revenue = $START.feedInStation1.electrolyzer.collectCosts.Q_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation1.electrolyzer.collectCosts.W_el_revenue (0.0 = $START.feedInStation1.electrolyzer.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.mass_H2 = $START.feedInStation2.electrolyzer.mass_H2 (0.0 = $START.feedInStation2.electrolyzer.mass_H2) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.mass_H2 = $START.feedInStation1.electrolyzer.mass_H2 (0.0 = $START.feedInStation1.electrolyzer.mass_H2) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed (0.0 = $START.pipe4.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced (0.0 = $START.pipe4.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed (0.0 = $START.pipe3.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced (0.0 = $START.pipe3.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed (0.0 = $START.pipe2.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced (0.0 = $START.pipe2.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed (0.0 = $START.pipe1.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced (0.0 = $START.pipe1.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_consumed (0.0 = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_produced (0.0 = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation2.electrolyzer.collectElectricPower.E = $START.feedInStation2.electrolyzer.collectElectricPower.E (0.0 = $START.feedInStation2.electrolyzer.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_consumed (0.0 = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_produced (0.0 = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: feedInStation1.electrolyzer.collectElectricPower.E = $START.feedInStation1.electrolyzer.collectElectricPower.E (0.0 = $START.feedInStation1.electrolyzer.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 0.5118/11.05, allocations: 354.8 MB / 6.339 GB, free: 89.48 MB / 2.402 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 0.0004699/11.05, allocations: 108 kB / 6.339 GB, free: 89.37 MB / 2.402 GB Notification: Performance of matching and sorting (n=7639) (initialization_lambda0): time 0.16/11.21, allocations: 99.24 MB / 6.436 GB, free: 9.18 MB / 2.417 GB Notification: Performance of prepare postOptimizeDAE: time 0.0003453/11.21, allocations: 308.5 kB / 6.437 GB, free: 8.848 MB / 2.417 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.002636/11.21, allocations: 1.277 MB / 6.438 GB, free: 7.57 MB / 2.417 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.8968/12.11, allocations: 3.476 MB / 6.441 GB, free: 0.7254 GB / 2.417 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.04556/12.15, allocations: 10.44 MB / 6.451 GB, free: 0.7254 GB / 2.417 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.03762/12.19, allocations: 68.22 MB / 6.518 GB, free: 0.677 GB / 2.417 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.03607/12.23, allocations: 1.786 MB / 6.52 GB, free: 0.677 GB / 2.417 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01264/12.24, allocations: 2.232 MB / 6.522 GB, free: 0.677 GB / 2.417 GB Warning: Assuming fixed start value for the following 64 variables: gasDemandProfiler.gasDemand_tot:VARIABLE(fixed = true ) \"Integrated gas demand in defined output\" type: Real gasDemandProfiler.gasDemand_base:VARIABLE(fixed = true ) \"Integrated base gas demand in defined output\" type: Real gasDemandProfiler.gasDemand_heat:VARIABLE(fixed = true ) \"Integrated heat gas demand in defined output\" type: Real gasDemandProfiler.Q_heatCharline:VARIABLE(unit = \"J\" fixed = true protected = true ) type: Real gasDemandProfiler.Q_heat:VARIABLE(unit = \"J\" fixed = true protected = true ) type: Real gasDemandProfiler.heatingLoadCharline.Q_dem:VARIABLE(unit = \"J\" fixed = true ) type: Real feedInStation1.controlTotalEly.controlElyOverload.state:DISCRETE(start = feedInStation1.controlTotalEly.startState fixed = true ) \"Defines the state the electrolyser is in (1: ready to overheat, 2: working in overload, 3: cooling down)\" type: Integer feedInStation1.controlTotalEly.controlElyOverload.overloadLevel:VARIABLE(start = 0.0 fixed = true ) \"Level of overheating\" type: Real feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y:VARIABLE(flow=false start = feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y_start_const fixed = true ) \"Connector of Real output signal\" type: Real feedInStation2.controlTotalEly.controlElyOverload.state:DISCRETE(start = feedInStation2.controlTotalEly.startState fixed = true ) \"Defines the state the electrolyser is in (1: ready to overheat, 2: working in overload, 3: cooling down)\" type: Integer feedInStation2.controlTotalEly.controlElyOverload.overloadLevel:VARIABLE(start = 0.0 fixed = true ) \"Level of overheating\" type: Real feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y:VARIABLE(flow=false start = feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y_start_const fixed = true ) \"Connector of Real output signal\" type: Real junction1.h:VARIABLE(start = init.junction1.h_in unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction1.p:VARIABLE(min = 0.0 start = init.junction1.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real pipe1.h[1]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[2]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[3]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[4]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.h[5]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe1.p[1]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[2]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[3]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[4]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe1.p[5]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.h[1]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[2]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[3]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[4]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.h[5]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe2.p[1]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[2]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[3]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[4]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe2.p[5]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.h[1]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[2]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[3]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[4]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.h[5]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe3.p[1]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[2]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[3]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[4]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe3.p[5]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.h[1]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[2]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[3]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[4]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[4] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.h[5]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[5] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [5] pipe4.p[1]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[2]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[3]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[4]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[4] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] pipe4.p[5]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[5] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [5] junction2.h:VARIABLE(start = init.junction2.h_out unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction2.p:VARIABLE(min = 0.0 start = init.junction2.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction3.h:VARIABLE(start = init.junction3.h_in unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction3.p:VARIABLE(min = 0.0 start = init.junction3.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction4.h:VARIABLE(start = init.junction4.h_out unit = \"J/kg\" fixed = true nominal = 1000.0 ) \"Specific enthalpy\" type: Real junction4.p:VARIABLE(min = 0.0 start = init.junction4.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction_feedIn1.h:VARIABLE(start = init.junction1.h_in unit = \"J/kg\" fixed = true ) \"Specific enthalpy\" type: Real junction_feedIn1.p:VARIABLE(min = 0.0 start = init.junction1.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real junction_feedIn2.h:VARIABLE(start = init.junction1.h_in unit = \"J/kg\" fixed = true ) \"Specific enthalpy\" type: Real junction_feedIn2.p:VARIABLE(min = 0.0 start = init.junction1.p unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real Warning: The initial conditions are over specified. The following 130 initial equations are redundant, so they are removed from the initialization_lambda0 system: feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueID feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP = $START.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.resetValueP feedInStation2.electrolyzer.collectCosts.W_el_demand = $START.feedInStation2.electrolyzer.collectCosts.W_el_demand feedInStation1.electrolyzer.collectCosts.W_el_demand = $START.feedInStation1.electrolyzer.collectCosts.W_el_demand pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue feedInStation2.electrolyzer.collectCosts.other_demand = $START.feedInStation2.electrolyzer.collectCosts.other_demand feedInStation2.electrolyzer.collectCosts.other_revenue = $START.feedInStation2.electrolyzer.collectCosts.other_revenue feedInStation2.electrolyzer.collectCosts.H_demand = $START.feedInStation2.electrolyzer.collectCosts.H_demand feedInStation2.electrolyzer.collectCosts.H_revenue = $START.feedInStation2.electrolyzer.collectCosts.H_revenue feedInStation2.electrolyzer.collectCosts.Q_demand = $START.feedInStation2.electrolyzer.collectCosts.Q_demand feedInStation2.electrolyzer.collectCosts.Q_revenue = $START.feedInStation2.electrolyzer.collectCosts.Q_revenue feedInStation2.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation2.electrolyzer.collectCosts.W_el_revenue feedInStation1.electrolyzer.collectCosts.other_demand = $START.feedInStation1.electrolyzer.collectCosts.other_demand feedInStation1.electrolyzer.collectCosts.other_revenue = $START.feedInStation1.electrolyzer.collectCosts.other_revenue feedInStation1.electrolyzer.collectCosts.H_demand = $START.feedInStation1.electrolyzer.collectCosts.H_demand feedInStation1.electrolyzer.collectCosts.H_revenue = $START.feedInStation1.electrolyzer.collectCosts.H_revenue feedInStation1.electrolyzer.collectCosts.Q_demand = $START.feedInStation1.electrolyzer.collectCosts.Q_demand feedInStation1.electrolyzer.collectCosts.Q_revenue = $START.feedInStation1.electrolyzer.collectCosts.Q_revenue feedInStation1.electrolyzer.collectCosts.W_el_revenue = $START.feedInStation1.electrolyzer.collectCosts.W_el_revenue feedInStation2.electrolyzer.mass_H2 = $START.feedInStation2.electrolyzer.mass_H2 feedInStation1.electrolyzer.mass_H2 = $START.feedInStation1.electrolyzer.mass_H2 modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced feedInStation2.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_consumed feedInStation2.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation2.electrolyzer.collectCosts.m_CDE_produced feedInStation2.electrolyzer.collectElectricPower.E = $START.feedInStation2.electrolyzer.collectElectricPower.E feedInStation1.electrolyzer.collectCosts.m_CDE_consumed = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_consumed feedInStation1.electrolyzer.collectCosts.m_CDE_produced = $START.feedInStation1.electrolyzer.collectCosts.m_CDE_produced feedInStation1.electrolyzer.collectElectricPower.E = $START.feedInStation1.electrolyzer.collectElectricPower.E modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1697 * Number of states: 0 () * Number of discrete variables: 108 (gasDemandProfiler.heatingLoadCharline.hour_of_day.count,$PRE.gasDemandProfiler.heatingLoadCharline.hour_of_day.count,gasDemandProfiler.heatingLoadCharline.hour_of_day.T_start,$PRE.gasDemandProfiler.heatingLoadCharline.hour_of_day.T_start,$whenCondition25,$PRE.gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEvent,$whenCondition24,gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEventScaled,$PRE.gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEventScaled,gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEvent,gasDemandProfiler.heatingLoadCharline.weekendPulse.pulse.count,$PRE.gasDemandProfiler.heatingLoadCharline.weekendPulse.pulse.count,gasDemandProfiler.heatingLoadCharline.weekendPulse.pulse.T_start,$PRE.gasDemandProfiler.heatingLoadCharline.weekendPulse.pulse.T_start,$whenCondition23,$PRE.gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEvent,$whenCondition22,gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEventScaled,$PRE.gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEventScaled,gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEvent,$PRE.residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEvent,$whenCondition10,$PRE.residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEvent,$whenCondition9,$PRE.residualLoad.PVTable.MSL_combiTimeTable.nextTimeEvent,$whenCondition8,$PRE.residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEvent,$whenCondition7,$PRE.residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEvent,$whenCondition6,$PRE.residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEvent,$whenCondition5,$PRE.residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition4,residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$PRE.residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition3,residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$PRE.feedInStation1.controlTotalEly.controlElyOverload.state,$PRE.feedInStation2.controlTotalEly.controlElyOverload.state,$PRE.gasDemandProfiler.weeklyHeatProfile.second_in_week.T_start,$PRE.gasDemandProfiler.weeklyHeatProfile.second_in_week.count,$PRE.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.time_lag_I_activation.entryTime,$PRE.feedInStation2.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,$PRE.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.time_lag_I_activation.entryTime,$PRE.feedInStation1.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,pipe4.heatTransfer.table_block.tableID,pipe3.heatTransfer.table_block.tableID,pipe2.heatTransfer.table_block.tableID,pipe1.heatTransfer.table_block.tableID,gasDemandProfiler.weeklyHeatProfile.isHeatingPeriod.y,gasDemandProfiler.weeklyHeatProfile.second_in_week.count,gasDemandProfiler.weeklyHeatProfile.second_in_week.T_start,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.booleanExpression.y,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.I_activation.y,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.booleanPassThrough.y,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.time_lag_I_activation.entryTime,feedInStation2.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,feedInStation2.controlTotalEly.controlElyOverload.state,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.booleanExpression.y,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.I_activation.y,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.booleanPassThrough.y,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.time_lag_I_activation.entryTime,feedInStation1.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,feedInStation1.controlTotalEly.controlElyOverload.state,residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.PVTable.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.PVTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.PVTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEventScaled,$PRE.residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEvent,$whenCondition21,$whenCondition20,$whenCondition19,$whenCondition18,$whenCondition17,$whenCondition16,$whenCondition15,$whenCondition14,$whenCondition11,$whenCondition12,$whenCondition13) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (4862): * Single equations (assignments): 4565 * Array equations: 0 * Algorithm blocks: 5 * Record equations: 238 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 26 * Torn equation systems: 28 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 26 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 26 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 2 systems {(2,17), (2,17)} Notification: Performance of prepare postOptimizeDAE: time 0.02104/12.26, allocations: 4.415 MB / 6.526 GB, free: 0.6751 GB / 2.417 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.01799/12.28, allocations: 5.98 MB / 6.532 GB, free: 0.6751 GB / 2.417 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.154/12.43, allocations: 86.19 MB / 6.616 GB, free: 0.6516 GB / 2.417 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.000667/12.43, allocations: 347.2 kB / 6.617 GB, free: 0.6516 GB / 2.417 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0001244/12.43, allocations: 65.94 kB / 6.617 GB, free: 0.6516 GB / 2.417 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.1119/12.54, allocations: 74.47 MB / 6.689 GB, free: 0.6237 GB / 2.417 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.2572/12.8, allocations: 178 MB / 6.863 GB, free: 475.4 MB / 2.417 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.00226/12.8, allocations: 0.9719 MB / 6.864 GB, free: 474.5 MB / 2.417 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.03273/12.84, allocations: 6.136 MB / 6.87 GB, free: 468.3 MB / 2.417 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.008251/12.84, allocations: 4.516 MB / 6.875 GB, free: 463.9 MB / 2.417 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.009989/12.85, allocations: 1.097 MB / 6.876 GB, free: 462.8 MB / 2.417 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.0239/12.88, allocations: 63.53 MB / 6.938 GB, free: 395.9 MB / 2.417 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.429e-05/12.88, allocations: 83.62 kB / 6.938 GB, free: 395.9 MB / 2.417 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1763/13.05, allocations: 135.5 MB / 7.07 GB, free: 262.5 MB / 2.417 GB Notification: Performance of postOpt removeConstants (simulation): time 0.1433/13.2, allocations: 88.32 MB / 7.156 GB, free: 176.7 MB / 2.417 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.02283/13.22, allocations: 0.7676 MB / 7.157 GB, free: 176 MB / 2.417 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.02949/13.25, allocations: 1.169 MB / 7.158 GB, free: 174.8 MB / 2.417 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.01161/13.26, allocations: 2.011 MB / 7.16 GB, free: 172.8 MB / 2.417 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.009665/13.27, allocations: 1.328 MB / 7.162 GB, free: 171.5 MB / 2.417 GB Notification: Performance of sorting global known variables: time 0.06214/13.33, allocations: 37.53 MB / 7.198 GB, free: 134.3 MB / 2.417 GB Notification: Performance of sort global known variables: time 1.91e-07/13.33, allocations: 0 / 7.198 GB, free: 134.3 MB / 2.417 GB Notification: Performance of remove unused functions: time 0.08947/13.42, allocations: 21.44 MB / 7.219 GB, free: 112.9 MB / 2.417 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 245 * Number of states: 218 (feedInStation1.controlTotalEly.controlElyOverload.overloadLevel,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y,feedInStation2.controlTotalEly.controlElyOverload.overloadLevel,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.I.y,gasDemandProfiler.gasDemand_tot,gasDemandProfiler.gasDemand_base,gasDemandProfiler.gasDemand_heat,gasDemandProfiler.Q_heatCharline,gasDemandProfiler.Q_heat,junction1.gasBulk.xi[1],junction1.gasBulk.xi[2],junction1.gasBulk.xi[3],junction1.gasBulk.xi[4],junction1.gasBulk.xi[5],junction1.gasBulk.xi[6],junction1.h,junction1.p,pipe1.h[1],pipe1.h[2],pipe1.h[3],pipe1.h[4],pipe1.h[5],pipe1.p[1],pipe1.p[2],pipe1.p[3],pipe1.p[4],pipe1.p[5],pipe1.xi[1,1],pipe1.xi[1,2],pipe1.xi[1,3],pipe1.xi[1,4],pipe1.xi[1,5],pipe1.xi[1,6],pipe1.xi[2,1],pipe1.xi[2,2],pipe1.xi[2,3],pipe1.xi[2,4],pipe1.xi[2,5],pipe1.xi[2,6],pipe1.xi[3,1],pipe1.xi[3,2],pipe1.xi[3,3],pipe1.xi[3,4],pipe1.xi[3,5],pipe1.xi[3,6],pipe1.xi[4,1],pipe1.xi[4,2],pipe1.xi[4,3],pipe1.xi[4,4],pipe1.xi[4,5],pipe1.xi[4,6],pipe1.xi[5,1],pipe1.xi[5,2],pipe1.xi[5,3],pipe1.xi[5,4],pipe1.xi[5,5],pipe1.xi[5,6],pipe2.h[1],pipe2.h[2],pipe2.h[3],pipe2.h[4],pipe2.h[5],pipe2.p[1],pipe2.p[2],pipe2.p[3],pipe2.p[4],pipe2.p[5],pipe2.xi[1,1],pipe2.xi[1,2],pipe2.xi[1,3],pipe2.xi[1,4],pipe2.xi[1,5],pipe2.xi[1,6],pipe2.xi[2,1],pipe2.xi[2,2],pipe2.xi[2,3],pipe2.xi[2,4],pipe2.xi[2,5],pipe2.xi[2,6],pipe2.xi[3,1],pipe2.xi[3,2],pipe2.xi[3,3],pipe2.xi[3,4],pipe2.xi[3,5],pipe2.xi[3,6],pipe2.xi[4,1],pipe2.xi[4,2],pipe2.xi[4,3],pipe2.xi[4,4],pipe2.xi[4,5],pipe2.xi[4,6],pipe2.xi[5,1],pipe2.xi[5,2],pipe2.xi[5,3],pipe2.xi[5,4],pipe2.xi[5,5],pipe2.xi[5,6],pipe3.h[1],pipe3.h[2],pipe3.h[3],pipe3.h[4],pipe3.h[5],pipe3.p[1],pipe3.p[2],pipe3.p[3],pipe3.p[4],pipe3.p[5],pipe3.xi[1,1],pipe3.xi[1,2],pipe3.xi[1,3],pipe3.xi[1,4],pipe3.xi[1,5],pipe3.xi[1,6],pipe3.xi[2,1],pipe3.xi[2,2],pipe3.xi[2,3],pipe3.xi[2,4],pipe3.xi[2,5],pipe3.xi[2,6],pipe3.xi[3,1],pipe3.xi[3,2],pipe3.xi[3,3],pipe3.xi[3,4],pipe3.xi[3,5],pipe3.xi[3,6],pipe3.xi[4,1],pipe3.xi[4,2],pipe3.xi[4,3],pipe3.xi[4,4],pipe3.xi[4,5],pipe3.xi[4,6],pipe3.xi[5,1],pipe3.xi[5,2],pipe3.xi[5,3],pipe3.xi[5,4],pipe3.xi[5,5],pipe3.xi[5,6],pipe4.h[1],pipe4.h[2],pipe4.h[3],pipe4.h[4],pipe4.h[5],pipe4.p[1],pipe4.p[2],pipe4.p[3],pipe4.p[4],pipe4.p[5],pipe4.xi[1,1],pipe4.xi[1,2],pipe4.xi[1,3],pipe4.xi[1,4],pipe4.xi[1,5],pipe4.xi[1,6],pipe4.xi[2,1],pipe4.xi[2,2],pipe4.xi[2,3],pipe4.xi[2,4],pipe4.xi[2,5],pipe4.xi[2,6],pipe4.xi[3,1],pipe4.xi[3,2],pipe4.xi[3,3],pipe4.xi[3,4],pipe4.xi[3,5],pipe4.xi[3,6],pipe4.xi[4,1],pipe4.xi[4,2],pipe4.xi[4,3],pipe4.xi[4,4],pipe4.xi[4,5],pipe4.xi[4,6],pipe4.xi[5,1],pipe4.xi[5,2],pipe4.xi[5,3],pipe4.xi[5,4],pipe4.xi[5,5],pipe4.xi[5,6],junction2.gasBulk.xi[1],junction2.gasBulk.xi[2],junction2.gasBulk.xi[3],junction2.gasBulk.xi[4],junction2.gasBulk.xi[5],junction2.gasBulk.xi[6],junction2.h,junction2.p,junction3.gasBulk.xi[1],junction3.gasBulk.xi[2],junction3.gasBulk.xi[3],junction3.gasBulk.xi[4],junction3.gasBulk.xi[5],junction3.gasBulk.xi[6],junction3.h,junction3.p,junction4.gasBulk.xi[1],junction4.gasBulk.xi[2],junction4.gasBulk.xi[3],junction4.gasBulk.xi[4],junction4.gasBulk.xi[5],junction4.gasBulk.xi[6],junction4.h,junction4.p,junction_feedIn1.gasBulk.xi[1],junction_feedIn1.gasBulk.xi[2],junction_feedIn1.gasBulk.xi[3],junction_feedIn1.gasBulk.xi[4],junction_feedIn1.gasBulk.xi[5],junction_feedIn1.gasBulk.xi[6],junction_feedIn1.h,junction_feedIn1.p,junction_feedIn2.gasBulk.xi[1],junction_feedIn2.gasBulk.xi[2],junction_feedIn2.gasBulk.xi[3],junction_feedIn2.gasBulk.xi[4],junction_feedIn2.gasBulk.xi[5],junction_feedIn2.gasBulk.xi[6],junction_feedIn2.h,junction_feedIn2.p,gasDemandProfiler.heatingLoadCharline.Q_dem) * Number of discrete variables: 72 ($whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition3,residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition4,residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.booleanPassThrough.y,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.booleanPassThrough.y,$whenCondition13,$whenCondition12,$whenCondition11,$whenCondition10,$whenCondition9,$whenCondition8,$whenCondition7,$whenCondition6,$whenCondition5,$whenCondition14,$whenCondition15,$whenCondition16,$whenCondition17,$whenCondition18,$whenCondition19,$whenCondition20,$whenCondition21,residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEvent,residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.PVTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.PVTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEventScaled,feedInStation1.controlTotalEly.controlElyOverload.state,feedInStation1.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.time_lag_I_activation.entryTime,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.I_activation.y,feedInStation1.controlTotalEly.controlElyMaximumFeedIn.booleanExpression.y,feedInStation2.controlTotalEly.controlElyOverload.state,feedInStation2.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.time_lag_I_activation.entryTime,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.I_activation.y,feedInStation2.controlTotalEly.controlElyMaximumFeedIn.booleanExpression.y,gasDemandProfiler.weeklyHeatProfile.second_in_week.T_start,gasDemandProfiler.weeklyHeatProfile.second_in_week.count,gasDemandProfiler.weeklyHeatProfile.isHeatingPeriod.y,pipe1.heatTransfer.table_block.tableID,pipe2.heatTransfer.table_block.tableID,pipe3.heatTransfer.table_block.tableID,pipe4.heatTransfer.table_block.tableID,$whenCondition22,gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEvent,gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition23,gasDemandProfiler.heatingLoadCharline.weekendPulse.pulse.T_start,gasDemandProfiler.heatingLoadCharline.weekendPulse.pulse.count,$whenCondition24,gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEvent,gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition25,gasDemandProfiler.heatingLoadCharline.hour_of_day.T_start,gasDemandProfiler.heatingLoadCharline.hour_of_day.count) * Number of discrete states: 39 (gasDemandProfiler.heatingLoadCharline.hour_of_day.count,gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEvent,gasDemandProfiler.heatingLoadCharline.OffsetvalueDailyprofile.MSL_combiTimeTable.nextTimeEventScaled,gasDemandProfiler.heatingLoadCharline.weekendPulse.pulse.count,gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEvent,gasDemandProfiler.heatingLoadCharline.SummerDayTypicalHeatLoad.MSL_combiTimeTable.nextTimeEventScaled,gasDemandProfiler.weeklyHeatProfile.second_in_week.count,residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.PVTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEvent,residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEvent,feedInStation1.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,feedInStation2.controlTotalEly.controlElyOverload.hysteresis_coolingDown.y,residualLoad.CHPTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.DemandTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.PVTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.OffshoreTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.OnshoreTable.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.RunOffWater.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition17,$whenCondition16,$whenCondition15,feedInStation2.controlTotalEly.controlElyOverload.state,$whenCondition14,$whenCondition21,$whenCondition20,$whenCondition19,feedInStation1.controlTotalEly.controlElyOverload.state,$whenCondition18,residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,residualLoad.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,residualLoad.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (2335): * Single equations (assignments): 2033 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 238 * When equations: 36 * If-equations: 0 * Equation systems (not torn): 28 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 26 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 2 systems {20, 20} [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 1.062/14.48, allocations: 141.6 MB / 7.357 GB, free: 0.7337 GB / 2.433 GB Notification: Performance of simCode: created initialization part: time 0.2087/14.69, allocations: 153.9 MB / 7.508 GB, free: 0.6728 GB / 2.433 GB Notification: Performance of simCode: created event and clocks part: time 6.665e-05/14.69, allocations: 15.5 kB / 7.508 GB, free: 0.6728 GB / 2.433 GB Notification: Performance of simCode: created simulation system equations: time 0.06979/14.76, allocations: 57.25 MB / 7.564 GB, free: 0.6459 GB / 2.433 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.06977/14.83, allocations: 14.52 MB / 7.578 GB, free: 0.6412 GB / 2.433 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:284:3-284:252:writable] Error: Variable pipe4.xi[5,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/SimCode/SimCodeUtil.mo:7684:5-7684:67:writable] Error: Internal error createModelInfo failed [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/SimCode/SimCodeUtil.mo:843:5-843:146:writable] Error: Internal error function createSimCode failed [Transformation from optimised DAE to simulation code structure failed] " [Timeout remaining time 645] [Calling sys.exit(0), Time elapsed: 22.6813781876117]