(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Components_Heat_ElectricAirHeater_Check_TestElectricAirHeater_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1500 --stepSize=0.6 --mode=cs --timeout=240 --tolerance=1e-05 ../TransiEnt_TransiEnt_Components_Heat_ElectricAirHeater_Check_TestElectricAirHeater_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-05 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : TransiEnt.Components.Heat.ElectricAirHeater.Check.TestElectricAirHeater (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1500.000000 - tolerance : 1e-05 - stepSize : 0.6 LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt warning: [fmi2Warning] TestElectricAirHeater/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt warning: [fmi2Warning] TestElectricAirHeater/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt) not in the resources directory. The FMU might not work as expected if you send it to a different system info: Result file: TransiEnt_TransiEnt_Components_Heat_ElectricAirHeater_Check_TestElectricAirHeater_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable TestElectricAirHeater.electricHeater.airVolume.complexity will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.complexity will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_Txim_flow.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.eyeOut.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.gas_a.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.boundaryGas_pTxi.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidInlet.gasType.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.fluidOutlet.gasType.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.inlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.outlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.inlet.mediumModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.airVolume.summary.outlet.mediumModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.inlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.insulation.scalar2VectorHeatPort.equalityMode will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.medium1.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.outlet.Medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.inlet.mediumModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.electricHeater.summary.outlet.mediumModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.absolute_path will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.complete_relative_path will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.environment_variable_name will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.genericFileName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.relativepath will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.Variable_Ground_Temperature.tableName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.airModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.electricityPrice.MSL_combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.MSL_combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.MSL_combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.absolute_path will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.complete_relative_path will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.environment_variable_name will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.genericFileName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.relativepath will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.electricityPrice.tableName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.exhaustGasModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.flueGasModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.fluid1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.fluid1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.fluid2.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.fluid2.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.fluid3.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.fluid3.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.vleFluidNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.vleFluidNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.vleFluidNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.vleFluidNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.vleFluidNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel1.vleFluidNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel2.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel3.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel3.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel4.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel4.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel4.vleFluidNames[2] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel4.vleFluidNames[3] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.gasModel4.vleFluidNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[1] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[2] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[3] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[4] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[5] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[6] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[7] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[8] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[9] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[10] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[11] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[12] will not be stored in the result file, because the signal type is not supported info: Parameter TestElectricAirHeater.simCenter.generationPark.index[13] will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.refrigerantFluid1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable TestElectricAirHeater.simCenter.refrigerantFluid1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported LOG_STDOUT | info | TILMedia-Error(TestElectricAirHeater.electricHeater.airVolume.fluid[1], GM_GasMixtureModel_computeSimpleCondensingProperties_phxi, mediumPointerID=5): h (=9.0556e+09 J/kg) > h_max (3.23212e+06 J/kg at T=3000 K), T limited to 3000 K, p=2.24889e+07 Pa, xi={7.03713e-09, -4.98248e-11, 0.000580067, -3.3878e-26, 0.754052, 0.231316, 1.92434e-26, 0.001, 1.15622e-09, 0.0130518} LOG_STDOUT | info | TILMedia-Error(TestElectricAirHeater.electricHeater.airVolume.fluid[3], GM_GasMixtureModel_computeSimpleCondensingProperties_phxi, mediumPointerID=9): h (=1.10896e+10 J/kg) > h_max (1.03719e+08 J/kg at T=3000 K), T limited to 3000 K, p=101300 Pa, xi={3.05167e-10, 9.383e-11, 0.000579895, -2.42666e-22, 44.0919, 11.0659, 5.38217e-22, 0.000999662, -3.05759e-11, -54.1594} LOG_STDOUT | info | TILMedia-Error(TestElectricAirHeater.electricHeater.airVolume.fluid[3], GM_GasMixtureModel_computeSimpleCondensingProperties_phxi, mediumPointerID=9): h (=1.10896e+10 J/kg) > h_max (1.03719e+08 J/kg at T=3000 K), T limited to 3000 K, p=101300 Pa, xi={3.05167e-10, 9.383e-11, 0.000579895, -2.42666e-22, 44.0919, 11.0659, 5.38217e-22, 0.000999662, -3.05759e-11, -54.1594} LOG_ASSERT | debug | Solving non-linear system 1328 failed at time=60.6000000000001. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Fatal] TestElectricAirHeater/logStatusFatal: fmi2DoStep: ##CVODE## -8 error occurred at time = 60.0000000000001. error: [fmi2logger] [fmi2Fatal] TestElectricAirHeater/logStatusFatal: fmi2DoStep: CVODE integrator step failed. error: [stepUntil] fmi2_doStep failed for FMU "TestElectricAirHeater.root.TestElectricAirHeater" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 2 warnings info: 3 errors