(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=30 --stepSize=0.03 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : ThermofluidStream.Processes.Tests.Compressor (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 30.000000 - tolerance : 1e-06 - stepSize : 0.03 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:1022:7-1022:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sink.inlet.state.T >= 1.0 and sink.inlet.state.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= sink.inlet.state.T <= 1e4, has value: -694.44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:1022:7-1022:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((junctionN.inlets[2].state.T >= 1.0 and junctionN.inlets[2].state.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= junctionN.inlets[2].state.T <= 1e4, has value: -704.286" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Compressor.compressor.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Compressor.compressor1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Compressor.junctionN.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Compressor.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Compressor.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Compressor.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Compressor.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Compressor.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Compressor.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Compressor.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Compressor.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Compressor.splitterN.instanceName will not be stored in the result file, because the signal type is not supported