(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step8ClosedLoopFiltered_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_ClausiusRankine_Step8ClosedLoopFiltered_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_ClausiusRankine_Step8ClosedLoopFiltered_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.ClausiusRankine.Step8ClosedLoopFiltered (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((condenser.p_min >= 611.657 and condenser.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= condenser.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((superheater.p_min >= 611.657 and superheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= superheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((preheater.p_min >= 611.657 and preheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boiler.p_min >= 611.657 and boiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= boiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step8ClosedLoopFiltered_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Step8ClosedLoopFiltered.boiler.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step8ClosedLoopFiltered.condenser.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Step8ClosedLoopFiltered.efficiencyExtensive.description will not be stored in the result file, because the signal type is not supported info: Parameter Step8ClosedLoopFiltered.efficiencySpecific.description will not be stored in the result file, because the signal type is not supported info: Variable Step8ClosedLoopFiltered.loopBreaker.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step8ClosedLoopFiltered.loopBreaker.name will not be stored in the result file, because the signal type is not supported info: Variable Step8ClosedLoopFiltered.preheater.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step8ClosedLoopFiltered.pump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step8ClosedLoopFiltered.superheater.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step8ClosedLoopFiltered.turbine.instanceName will not be stored in the result file, because the signal type is not supported