Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo): time 0.5111/0.5111, allocations: 111.7 MB / 130.8 MB, free: 5.285 MB / 122.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation",fmuType="me_cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation",fmuType="me_cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 2.665e-06/2.665e-06, allocations: 0 / 210.1 MB, free: 7.043 MB / 202.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.987e-05/2.253e-05, allocations: 6.219 kB / 210.1 MB, free: 7.035 MB / 202.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation): time 1.55/1.55, allocations: 334.3 MB / 0.5317 GB, free: 3.441 MB / 458.8 MB Notification: Performance of NFInst.instExpressions: time 0.2224/1.772, allocations: 205.6 MB / 0.7325 GB, free: 7.469 MB / 0.6512 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02109/1.793, allocations: 247.1 kB / 0.7327 GB, free: 7.227 MB / 0.6512 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:24:3-25:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/BoundaryConditions/SinkP.mo:13:3-14:80:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:59:3-60:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:61:3-62:79:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:67:3-68:81:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:69:3-70:79:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SourceQ.mo:13:3-14:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SinkP.mo:19:3-20:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:18:3-19:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:20:3-21:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:20:3-21:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:24:3-25:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:26:3-27:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Combustion/BoundaryConditions/FuelSourcePQ.mo:18:3-19:78:writable] Warning: Connector C is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SourcePQ.mo:16:3-17:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/BoundaryConditions/SourcePQ.mo:15:3-16:78:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/BoundaryConditions/AirHumidity.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/BoundaryConditions/AirHumidity.mo:26:3-27:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/Machines/Compressor.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/Machines/Compressor.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:62:3-63:80:writable] Warning: Connector Cfuel is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:64:3-65:80:writable] Warning: Connector Ca is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:66:3-67:78:writable] Warning: Connector Cfg is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:68:3-69:79:writable] Warning: Connector Cws is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/Machines/CombustionTurbine.mo:27:3-28:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/Machines/CombustionTurbine.mo:29:3-30:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/TAC/GasTurbine.mo:31:3-32:78:writable] Warning: Connector Entree_air is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/TAC/GasTurbine.mo:33:3-34:76:writable] Warning: Connector Sortie_fumees is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/TAC/GasTurbine.mo:35:3-36:79:writable] Warning: Connector Entree_eau_combustion is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/TAC/GasTurbine.mo:37:3-38:77:writable] Warning: Connector Entree_combustible is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:18:3-19:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:20:3-21:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01682/1.81, allocations: 4.791 MB / 0.7374 GB, free: 2.441 MB / 0.6512 GB Notification: Performance of NFTyping.typeBindings: time 0.3919/2.202, allocations: 14.68 MB / 0.7517 GB, free: 4.516 MB / 0.6512 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:964:9-964:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.05739/2.26, allocations: 28.75 MB / 0.7798 GB, free: 2.953 MB / 0.6512 GB Notification: Performance of NFFlatten.flatten: time 0.08363/2.343, allocations: 86.72 MB / 0.8645 GB, free: 440 kB / 0.6824 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04368/2.387, allocations: 24.8 MB / 0.8887 GB, free: 8.738 MB / 0.7137 GB Notification: Performance of NFEvalConstants.evaluate: time 0.08506/2.472, allocations: 40.97 MB / 0.9287 GB, free: 1.445 MB / 0.7449 GB Notification: Performance of NFSimplifyModel.simplify: time 0.04638/2.518, allocations: 28.85 MB / 0.9569 GB, free: 6.727 MB / 0.7762 GB Notification: Performance of NFPackage.collectConstants: time 0.02255/2.541, allocations: 6.203 MB / 0.9629 GB, free: 0.5234 MB / 0.7762 GB Notification: Performance of NFFlatten.collectFunctions: time 0.06333/2.604, allocations: 32.84 MB / 0.995 GB, free: 140 kB / 0.8074 GB Notification: Performance of NFScalarize.scalarize: time 0.02989/2.634, allocations: 18.6 MB / 1.013 GB, free: 14.56 MB / 0.8387 GB Notification: Performance of NFVerifyModel.verify: time 0.04837/2.683, allocations: 19.34 MB / 1.032 GB, free: 12.18 MB / 0.8543 GB Notification: Performance of NFConvertDAE.convert: time 0.7949/3.477, allocations: 91.44 MB / 1.121 GB, free: 122.2 MB / 0.8544 GB Notification: Performance of FrontEnd - DAE generated: time 7.915e-06/3.477, allocations: 2.781 kB / 1.121 GB, free: 122.2 MB / 0.8544 GB Notification: Performance of FrontEnd: time 2.224e-06/3.477, allocations: 0.6875 kB / 1.121 GB, free: 122.2 MB / 0.8544 GB Notification: Performance of Transformations before backend: time 0.002651/3.48, allocations: 0 / 1.121 GB, free: 122.2 MB / 0.8544 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 11076 * Number of variables: 11076 Notification: Performance of Generate backend data structure: time 0.212/3.692, allocations: 78.71 MB / 1.198 GB, free: 87 MB / 0.8544 GB Notification: Performance of prepare preOptimizeDAE: time 5.99e-05/3.692, allocations: 14.67 kB / 1.198 GB, free: 86.99 MB / 0.8544 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.02804/3.72, allocations: 5.261 MB / 1.203 GB, free: 83.23 MB / 0.8544 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.03941/3.76, allocations: 7.218 MB / 1.21 GB, free: 76.67 MB / 0.8544 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.04319/3.803, allocations: 16.75 MB / 1.227 GB, free: 61.03 MB / 0.8544 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.01408/3.817, allocations: 20.51 MB / 1.247 GB, free: 36.81 MB / 0.8544 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.02265/3.839, allocations: 2.996 MB / 1.25 GB, free: 33.81 MB / 0.8544 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.179/4.018, allocations: 72.34 MB / 1.32 GB, free: 8.379 MB / 0.9013 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001102/4.02, allocations: 44.69 kB / 1.32 GB, free: 8.363 MB / 0.9013 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.02275/4.042, allocations: 1.201 MB / 1.322 GB, free: 7.164 MB / 0.9013 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001092/4.043, allocations: 1.355 MB / 1.323 GB, free: 5.809 MB / 0.9013 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.4507/4.494, allocations: 87.41 MB / 1.408 GB, free: 449.3 MB / 0.9481 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.423/4.917, allocations: 205.7 MB / 1.609 GB, free: 299.3 MB / 0.9481 GB Notification: Performance of preOpt comSubExp (simulation): time 0.114/5.031, allocations: 68.97 MB / 1.676 GB, free: 230.5 MB / 0.9481 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.09495/5.126, allocations: 49.82 MB / 1.725 GB, free: 180.9 MB / 0.9481 GB Notification: Performance of preOpt evalFunc (simulation): time 0.1409/5.267, allocations: 87.2 MB / 1.81 GB, free: 93.95 MB / 0.9481 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.1183/5.385, allocations: 56.23 MB / 1.865 GB, free: 37.61 MB / 0.9481 GB Notification: Performance of pre-optimization done (n=7457): time 6.201e-05/5.385, allocations: 4 kB / 1.865 GB, free: 37.61 MB / 0.9481 GB Notification: Performance of matching and sorting (n=7465): time 1.238/6.623, allocations: 373.6 MB / 2.23 GB, free: 204 MB / 0.9481 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002944/6.623, allocations: 1.016 MB / 2.231 GB, free: 202.9 MB / 0.9481 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.01106/6.634, allocations: 9.69 MB / 2.24 GB, free: 193.2 MB / 0.9481 GB Notification: Performance of collectPreVariables (initialization): time 0.01928/6.654, allocations: 0.6774 MB / 2.241 GB, free: 192.5 MB / 0.9481 GB Notification: Performance of collectInitialEqns (initialization): time 0.005466/6.659, allocations: 8.129 MB / 2.249 GB, free: 184.4 MB / 0.9481 GB Notification: Performance of collectInitialBindings (initialization): time 0.03277/6.692, allocations: 25.96 MB / 2.274 GB, free: 158.8 MB / 0.9481 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.06364/6.756, allocations: 9.564 MB / 2.284 GB, free: 149.2 MB / 0.9481 GB Notification: Performance of setup shared object (initialization): time 4.34e-05/6.756, allocations: 301.1 kB / 2.284 GB, free: 148.9 MB / 0.9481 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.08369/6.839, allocations: 44.53 MB / 2.327 GB, free: 104.4 MB / 0.9481 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.1026/6.942, allocations: 51.5 MB / 2.378 GB, free: 51.34 MB / 0.9481 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 0.9319/7.874, allocations: 300.5 MB / 2.671 GB, free: 248.9 MB / 0.9481 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001637/7.874, allocations: 32.75 kB / 2.671 GB, free: 248.9 MB / 0.9481 GB Notification: Performance of matching and sorting (n=8244) (initialization): time 0.3636/8.238, allocations: 145.8 MB / 2.814 GB, free: 104.7 MB / 0.9481 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001474/8.238, allocations: 103.4 kB / 2.814 GB, free: 104.6 MB / 0.9481 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0005924/8.238, allocations: 159.9 kB / 2.814 GB, free: 104.4 MB / 0.9481 GB Notification: Performance of postOpt tearingSystem (initialization): time 3.37/11.61, allocations: 1.792 GB / 4.606 GB, free: 74.34 MB / 0.9481 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01241/11.62, allocations: 3.545 MB / 4.609 GB, free: 71.82 MB / 0.9481 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.7307/12.35, allocations: 195.9 MB / 4.8 GB, free: 359.7 MB / 0.9481 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.05035/12.4, allocations: 6.119 MB / 4.806 GB, free: 359.1 MB / 0.9481 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.02234/12.42, allocations: 1.983 MB / 4.808 GB, free: 358.8 MB / 0.9481 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.HP_Economizer_4.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.HP_SuperHeater_1.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.HP_SuperHeater_2.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.IP_SuperHeater_2.TwoPhaseFlowPipe.Q[4] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 450 * Number of states: 0 () * Number of discrete variables: 289 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal,$whenCondition1,HP_IP_PressureLoss.C2.b,HP_IP_PressureLoss.C1.a,HP_PressureLoss_1.C2.b,HP_PressureLoss_1.C1.a,SeparateurMP.Cs2.b,SeparateurMP.Cs1.b,SeparateurMP.Ce2.a,SeparateurMP.Ce1.a,GasTurbine.TurbineAgaz.Cs.b,GasTurbine.TurbineAgaz.Ce.a,GasTurbine.chambreCombustionTAC.Cws.a,GasTurbine.chambreCombustionTAC.Cfg.b,GasTurbine.chambreCombustionTAC.Ca.a,GasTurbine.chambreCombustionTAC.Cfuel.a,GasTurbine.Compresseur.Cs.b,GasTurbine.Compresseur.Ce.a,GasTurbine.xAIR.C2.b,GasTurbine.xAIR.C1.a,SourceFumees.C.b,sourceEau.C.b,sourceCombustible.C.b,IP_Turbine_Valve.C2.b,IP_Turbine_Valve.C1.a,VolumeIP.Ce3.a,VolumeIP.Cs.b,VolumeIP.Ce2.a,VolumeIP.Ce1.a,VolumePreTHP.Cs3.b,VolumePreTHP.Cs2.b,VolumePreTHP.Cs1.b,VolumePreTHP.Ce.a,HPIP_FeedValve2.C2.b,HPIP_FeedValve2.C1.a,HPIP_FeedValve1.C2.b,HPIP_FeedValve1.C1.a,VolumeECO_HP2_3.Ce3.a,VolumeECO_HP2_3.Cs.b,VolumeECO_HP2_3.Ce2.a,VolumeECO_HP2_3.Ce1.a,VolumeECO_HP1_2.Ce3.a,VolumeECO_HP1_2.Cs.b,VolumeECO_HP1_2.Ce2.a,VolumeECO_HP1_2.Ce1.a,HP_Turbine_Valve.C2.b,HP_Turbine_Valve.C1.a,HP_PressureLoss_2.C2.b,HP_PressureLoss_2.C1.a,SensorQ_SteamCondenser.C2.b,SensorQ_SteamCondenser.C1.a,SensorQ_WaterCondenser.C2.b,SensorQ_WaterCondenser.C1.a,SensorQ_WaterBP_Out.C2.b,SensorQ_WaterBP_Out.C1.a,SensorQ_WaterBP.C2.b,SensorQ_WaterBP.C1.a,SensorQ_SteamBP.C2.b,SensorQ_SteamBP.C1.a,SensorQ_SteamMP.C2.b,SensorQ_SteamMP.C1.a,SensorQ_WaterMP.C2.b,SensorQ_WaterMP.C1.a,SensorQ_WaterHP.C2.b,SensorQ_WaterHP.C1.a,SensorQ_SteamHP.C2.b,SensorQ_SteamHP.C1.a,ExtractionValve.C2.b,ExtractionValve.C1.a,Dp_Cond_Out1.C2.b,Dp_Cond_Out1.C1.a,LP_Pump.C2.b,LP_Pump.C1.a,Dp_Cond_Out.C2.b,Dp_Cond_Out.C1.a,DP_IP_Pump.C2.b,DP_IP_Pump.C1.a,DP_HP_Pump.C2.b,DP_HP_Pump.C1.a,Dp_LP_Turbine.C2.b,Dp_LP_Turbine.C1.a,DoubleDebitBP.Cs.b,DoubleDebitBP.Ce.a,MoitieDebitBP.Cs.b,MoitieDebitBP.Ce.a,HP_Pump.C2.b,HP_Pump.C1.a,IP_Pump.C2.b,IP_Pump.C1.a,VolumeAlimMPHP.Cs2.b,VolumeAlimMPHP.Cs1.b,VolumeAlimMPHP.Ce2.a,VolumeAlimMPHP.Ce1.a,Dp_Cond_Out2.C2.b,Dp_Cond_Out2.C1.a,VolumeCond1.Ce3.a,VolumeCond1.Cs.b,VolumeCond1.Ce2.a,VolumeCond1.Ce1.a,Dp_Cond_In.C2.b,Dp_Cond_In.C1.a,PuitsCaloporteur.C.a,SourceCaloporteur.C.b,Condenser.Cse.b,Condenser.Cee.a,Condenser.Cl.b,Condenser.Cv.a,MoitieDebitHP.Cs.b,MoitieDebitHP.Ce.a,DoubleDebitMP.Cs.b,DoubleDebitMP.Ce.a,DoubleDebitHP.Cs.b,DoubleDebitHP.Ce.a,LP_Turbine.Cs.b,LP_Turbine.Ce.a,VolumeIP1.Ce3.a,VolumeIP1.Cs.b,VolumeIP1.Ce2.a,VolumeIP1.Ce1.a,IP_Turbine.Cs.b,IP_Turbine.Ce.a,HP_Turbine.Cs.b,HP_Turbine.Ce.a,LP_Economizer.TwoPhaseFlowPipe.C2.b,LP_Economizer.TwoPhaseFlowPipe.C1.a,LP_Economizer.ExchangerFlueGasesMetal.C2.b,LP_Economizer.ExchangerFlueGasesMetal.C1.a,SinkP_Gas.C.a,LP_SuperHeater.TwoPhaseFlowPipe.C2.b,LP_SuperHeater.TwoPhaseFlowPipe.C1.a,LP_SuperHeater.ExchangerFlueGasesMetal.C2.b,LP_SuperHeater.ExchangerFlueGasesMetal.C1.a,HPIP_FeedValve.C2.b,HPIP_FeedValve.C1.a,LP_Evaporator.TwoPhaseFlowPipe.C2.b,LP_Evaporator.TwoPhaseFlowPipe.C1.a,LP_Evaporator.ExchangerFlueGasesMetal.C2.b,LP_Evaporator.ExchangerFlueGasesMetal.C1.a,VolumeEvapBP.Ce3.a,VolumeEvapBP.Cs.b,VolumeEvapBP.Ce2.a,VolumeEvapBP.Ce1.a,LP_DownComer.C2.b,LP_DownComer.C1.a,LP_FeedValve.C2.b,LP_FeedValve.C1.a,LP_SteamValve.C2.b,LP_SteamValve.C1.a,LP_Drum.Cs.b,LP_Drum.Ce3.a,LP_Drum.Ce2.a,LP_Drum.Cv.b,LP_Drum.Cd.b,LP_Drum.Cm.a,LP_Drum.Ce1.a,IP_SuperHeater_3.TwoPhaseFlowPipe.C2.b,IP_SuperHeater_3.TwoPhaseFlowPipe.C1.a,IP_SuperHeater_3.ExchangerFlueGasesMetal.C2.b,IP_SuperHeater_3.ExchangerFlueGasesMetal.C1.a,IP_SuperHeater_2.TwoPhaseFlowPipe.C2.b,IP_SuperHeater_2.TwoPhaseFlowPipe.C1.a,IP_SuperHeater_2.ExchangerFlueGasesMetal.C2.b,IP_SuperHeater_2.ExchangerFlueGasesMetal.C1.a,VolumeLP.Cs2.b,VolumeLP.Cs1.b,VolumeLP.Ce2.a,VolumeLP.Ce1.a,IP_SuperHeater_1.TwoPhaseFlowPipe.C2.b,IP_SuperHeater_1.TwoPhaseFlowPipe.C1.a,IP_SuperHeater_1.ExchangerFlueGasesMetal.C2.b,IP_SuperHeater_1.ExchangerFlueGasesMetal.C1.a,IP_Economizer.TwoPhaseFlowPipe.C2.b,IP_Economizer.TwoPhaseFlowPipe.C1.a,IP_Economizer.ExchangerFlueGasesMetal.C2.b,IP_Economizer.ExchangerFlueGasesMetal.C1.a,VolumeEvapMP.Ce3.a,VolumeEvapMP.Cs.b,VolumeEvapMP.Ce2.a,VolumeEvapMP.Ce1.a,IP_DownComer.C2.b,IP_DownComer.C1.a,IP_Evaporator.TwoPhaseFlowPipe.C2.b,IP_Evaporator.TwoPhaseFlowPipe.C1.a,IP_Evaporator.ExchangerFlueGasesMetal.C2.b,IP_Evaporator.ExchangerFlueGasesMetal.C1.a,IP_SteamValve.C2.b,IP_SteamValve.C1.a,IP_FeedValve.C2.b,IP_FeedValve.C1.a,IP_Drum.Cs.b,IP_Drum.Ce3.a,IP_Drum.Ce2.a,IP_Drum.Cv.b,IP_Drum.Cd.b,IP_Drum.Cm.a,IP_Drum.Ce1.a,HP_SuperHeater_3.TwoPhaseFlowPipe.C2.b,HP_SuperHeater_3.TwoPhaseFlowPipe.C1.a,HP_SuperHeater_3.ExchangerFlueGasesMetal.C2.b,HP_SuperHeater_3.ExchangerFlueGasesMetal.C1.a,HP_SuperHeater_2.TwoPhaseFlowPipe.C2.b,HP_SuperHeater_2.TwoPhaseFlowPipe.C1.a,HP_SuperHeater_2.ExchangerFlueGasesMetal.C2.b,HP_SuperHeater_2.ExchangerFlueGasesMetal.C1.a,HP_Economizer_1.TwoPhaseFlowPipe.C2.b,HP_Economizer_1.TwoPhaseFlowPipe.C1.a,HP_Economizer_1.ExchangerFlueGasesMetal.C2.b,HP_Economizer_1.ExchangerFlueGasesMetal.C1.a,HP_Economizer_2.TwoPhaseFlowPipe.C2.b,HP_Economizer_2.TwoPhaseFlowPipe.C1.a,HP_Economizer_2.ExchangerFlueGasesMetal.C2.b,HP_Economizer_2.ExchangerFlueGasesMetal.C1.a,HP_Economizer_3.TwoPhaseFlowPipe.C2.b,HP_Economizer_3.TwoPhaseFlowPipe.C1.a,HP_Economizer_3.ExchangerFlueGasesMetal.C2.b,HP_Economizer_3.ExchangerFlueGasesMetal.C1.a,HP_SuperHeater_1.TwoPhaseFlowPipe.C2.b,HP_SuperHeater_1.TwoPhaseFlowPipe.C1.a,HP_SuperHeater_1.ExchangerFlueGasesMetal.C2.b,HP_SuperHeater_1.ExchangerFlueGasesMetal.C1.a,HP_Economizer_4.TwoPhaseFlowPipe.C2.b,HP_Economizer_4.TwoPhaseFlowPipe.C1.a,HP_Economizer_4.ExchangerFlueGasesMetal.C2.b,HP_Economizer_4.ExchangerFlueGasesMetal.C1.a,HP_Evaporator.TwoPhaseFlowPipe.C2.b,HP_Evaporator.TwoPhaseFlowPipe.C1.a,HP_Evaporator.ExchangerFlueGasesMetal.C2.b,HP_Evaporator.ExchangerFlueGasesMetal.C1.a,VolumeEvapHP.Ce3.a,VolumeEvapHP.Cs.b,VolumeEvapHP.Ce2.a,VolumeEvapHP.Ce1.a,HP_DownComer.C2.b,HP_DownComer.C1.a,HP_SteamValve.C2.b,HP_SteamValve.C1.a,HP_FeedValve.C2.b,HP_FeedValve.C1.a,HP_Drum.Cs.b,HP_Drum.Ce3.a,HP_Drum.Ce2.a,HP_Drum.Cv.b,HP_Drum.Cd.b,HP_Drum.Cm.a,HP_Drum.Ce1.a,SeparateurMP.Ce2.b,VolumeIP.Ce3.b,VolumeIP.Ce2.b,VolumePreTHP.Cs2.a,VolumePreTHP.Cs1.a,VolumeECO_HP2_3.Ce3.b,VolumeECO_HP2_3.Ce2.b,VolumeECO_HP1_2.Ce3.b,VolumeECO_HP1_2.Ce2.b,VolumeAlimMPHP.Ce2.b,VolumeCond1.Ce2.b,VolumeCond1.Ce1.b,VolumeEvapBP.Ce3.b,VolumeEvapBP.Ce2.b,LP_Drum.Ce3.b,LP_Drum.Ce2.b,VolumeLP.Cs1.a,VolumeEvapMP.Ce3.b,VolumeEvapMP.Ce2.b,IP_Drum.Cs.a,IP_Drum.Ce3.b,IP_Drum.Ce2.b,VolumeEvapHP.Ce3.b,VolumeEvapHP.Ce2.b,HP_Drum.Cs.a,HP_Drum.Ce3.b,HP_Drum.Ce2.b) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1434): * Single equations (assignments): 1343 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 64 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 12 * Torn equation systems: 13 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 1 system {(2,100.0%)} * Non-linear Jacobian (size): 11 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 12 systems {(1,1), (1,1), (1,15), (1,3), (1,5), (1,15), (314,2974), (1,1), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.05686/12.48, allocations: 9.048 MB / 4.817 GB, free: 354.5 MB / 0.9481 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.02737/12.51, allocations: 3.117 MB / 4.82 GB, free: 354.5 MB / 0.9481 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.3849/12.89, allocations: 163.7 MB / 4.98 GB, free: 235 MB / 0.9481 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.337/13.23, allocations: 144.4 MB / 5.121 GB, free: 90.76 MB / 0.9481 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002709/13.23, allocations: 24 kB / 5.121 GB, free: 90.73 MB / 0.9481 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001597/13.23, allocations: 290.9 kB / 5.121 GB, free: 90.45 MB / 0.9481 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.9302/14.16, allocations: 246.5 MB / 5.362 GB, free: 336.9 MB / 0.9481 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001101/14.16, allocations: 61.34 kB / 5.362 GB, free: 336.9 MB / 0.9481 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.05155/14.21, allocations: 15.49 MB / 5.377 GB, free: 325.6 MB / 0.9481 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.09138/14.31, allocations: 52.24 MB / 5.428 GB, free: 281.7 MB / 0.9481 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.02169/14.33, allocations: 1.921 MB / 5.43 GB, free: 279.8 MB / 0.9481 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.5897/14.92, allocations: 327.1 MB / 5.75 GB, free: 322.8 MB / 0.9481 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 5.7e-06/14.92, allocations: 11.22 kB / 5.75 GB, free: 322.8 MB / 0.9481 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.4505/15.37, allocations: 214.9 MB / 5.959 GB, free: 223.3 MB / 0.9481 GB Notification: Performance of postOpt removeConstants (simulation): time 0.04384/15.41, allocations: 11.85 MB / 5.971 GB, free: 212.5 MB / 0.9481 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.02259/15.43, allocations: 1.189 MB / 5.972 GB, free: 211.3 MB / 0.9481 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.04862/15.48, allocations: 6.121 MB / 5.978 GB, free: 205.3 MB / 0.9481 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.02608/15.51, allocations: 4.441 MB / 5.983 GB, free: 200.9 MB / 0.9481 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01946/15.53, allocations: 2.092 MB / 5.985 GB, free: 198.8 MB / 0.9481 GB Notification: Performance of sorting global known variables: time 0.008182/15.54, allocations: 6.004 MB / 5.99 GB, free: 192.8 MB / 0.9481 GB Notification: Performance of sort global known variables: time 2.01e-07/15.54, allocations: 0 / 5.99 GB, free: 192.8 MB / 0.9481 GB Notification: Performance of remove unused functions: time 0.08238/15.62, allocations: 15.77 MB / 6.006 GB, free: 177.2 MB / 0.9481 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 24 * Number of states: 242 (SeparateurMP.h,VolumeIP.h,VolumeIP.P,VolumePreTHP.h,VolumePreTHP.P,VolumeECO_HP2_3.h,VolumeECO_HP2_3.P,VolumeECO_HP1_2.h,VolumeECO_HP1_2.P,regulation_Niveau_Condenseur.pT1_3.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_HP.pIsat.Integrateur1.x,VolumeAlimMPHP.h,VolumeCond1.h,Condenser.Vl,Condenser.hv,Condenser.hl,Condenser.P,VolumeIP1.h,LP_Economizer.TwoPhaseFlowPipe.h[4],LP_Economizer.TwoPhaseFlowPipe.h[3],LP_Economizer.TwoPhaseFlowPipe.h[2],LP_Economizer.TwoPhaseFlowPipe.Q[4],LP_Economizer.TwoPhaseFlowPipe.Q[3],LP_Economizer.TwoPhaseFlowPipe.Q[2],LP_Economizer.TwoPhaseFlowPipe.Q[1],LP_Economizer.TwoPhaseFlowPipe.P[4],LP_Economizer.TwoPhaseFlowPipe.P[3],LP_Economizer.TwoPhaseFlowPipe.P[2],LP_Economizer.ExchangerWall.Tp[3],LP_Economizer.ExchangerWall.Tp[2],LP_Economizer.ExchangerWall.Tp[1],LP_SuperHeater.TwoPhaseFlowPipe.h[4],LP_SuperHeater.TwoPhaseFlowPipe.h[3],LP_SuperHeater.TwoPhaseFlowPipe.h[2],LP_SuperHeater.TwoPhaseFlowPipe.P[4],LP_SuperHeater.TwoPhaseFlowPipe.P[3],LP_SuperHeater.TwoPhaseFlowPipe.P[2],LP_SuperHeater.ExchangerWall.Tp[3],LP_SuperHeater.ExchangerWall.Tp[2],LP_SuperHeater.ExchangerWall.Tp[1],LP_Evaporator.TwoPhaseFlowPipe.h[4],LP_Evaporator.TwoPhaseFlowPipe.h[3],LP_Evaporator.TwoPhaseFlowPipe.h[2],LP_Evaporator.TwoPhaseFlowPipe.Q[4],LP_Evaporator.TwoPhaseFlowPipe.Q[3],LP_Evaporator.TwoPhaseFlowPipe.Q[2],LP_Evaporator.TwoPhaseFlowPipe.Q[1],LP_Evaporator.TwoPhaseFlowPipe.P[4],LP_Evaporator.TwoPhaseFlowPipe.P[3],LP_Evaporator.TwoPhaseFlowPipe.P[2],LP_Evaporator.ExchangerWall.Tp[3],LP_Evaporator.ExchangerWall.Tp[2],LP_Evaporator.ExchangerWall.Tp[1],VolumeEvapBP.h,LP_Drum.Vl,LP_Drum.Tp,LP_Drum.hv,LP_Drum.hl,LP_Drum.P,IP_SuperHeater_3.TwoPhaseFlowPipe.h[4],IP_SuperHeater_3.TwoPhaseFlowPipe.h[3],IP_SuperHeater_3.TwoPhaseFlowPipe.h[2],IP_SuperHeater_3.TwoPhaseFlowPipe.Q[4],IP_SuperHeater_3.TwoPhaseFlowPipe.Q[3],IP_SuperHeater_3.TwoPhaseFlowPipe.Q[2],IP_SuperHeater_3.TwoPhaseFlowPipe.P[4],IP_SuperHeater_3.TwoPhaseFlowPipe.P[3],IP_SuperHeater_3.TwoPhaseFlowPipe.P[2],IP_SuperHeater_3.ExchangerWall.Tp[3],IP_SuperHeater_3.ExchangerWall.Tp[2],IP_SuperHeater_3.ExchangerWall.Tp[1],IP_SuperHeater_2.TwoPhaseFlowPipe.h[4],IP_SuperHeater_2.TwoPhaseFlowPipe.h[3],IP_SuperHeater_2.TwoPhaseFlowPipe.h[2],IP_SuperHeater_2.TwoPhaseFlowPipe.Q[4],IP_SuperHeater_2.TwoPhaseFlowPipe.Q[3],IP_SuperHeater_2.TwoPhaseFlowPipe.Q[2],IP_SuperHeater_2.TwoPhaseFlowPipe.Q[1],IP_SuperHeater_2.TwoPhaseFlowPipe.P[4],IP_SuperHeater_2.TwoPhaseFlowPipe.P[3],IP_SuperHeater_2.TwoPhaseFlowPipe.P[2],IP_SuperHeater_2.ExchangerWall.Tp[3],IP_SuperHeater_2.ExchangerWall.Tp[2],IP_SuperHeater_2.ExchangerWall.Tp[1],VolumeLP.h,IP_SuperHeater_1.TwoPhaseFlowPipe.h[4],IP_SuperHeater_1.TwoPhaseFlowPipe.h[3],IP_SuperHeater_1.TwoPhaseFlowPipe.h[2],IP_SuperHeater_1.TwoPhaseFlowPipe.P[4],IP_SuperHeater_1.TwoPhaseFlowPipe.P[3],IP_SuperHeater_1.TwoPhaseFlowPipe.P[2],IP_SuperHeater_1.ExchangerWall.Tp[3],IP_SuperHeater_1.ExchangerWall.Tp[2],IP_SuperHeater_1.ExchangerWall.Tp[1],IP_Economizer.TwoPhaseFlowPipe.h[4],IP_Economizer.TwoPhaseFlowPipe.h[3],IP_Economizer.TwoPhaseFlowPipe.h[2],IP_Economizer.TwoPhaseFlowPipe.Q[4],IP_Economizer.TwoPhaseFlowPipe.Q[3],IP_Economizer.TwoPhaseFlowPipe.Q[2],IP_Economizer.TwoPhaseFlowPipe.Q[1],IP_Economizer.TwoPhaseFlowPipe.P[4],IP_Economizer.TwoPhaseFlowPipe.P[3],IP_Economizer.TwoPhaseFlowPipe.P[2],IP_Economizer.ExchangerWall.Tp[3],IP_Economizer.ExchangerWall.Tp[2],IP_Economizer.ExchangerWall.Tp[1],VolumeEvapMP.h,IP_Evaporator.TwoPhaseFlowPipe.h[4],IP_Evaporator.TwoPhaseFlowPipe.h[3],IP_Evaporator.TwoPhaseFlowPipe.h[2],IP_Evaporator.TwoPhaseFlowPipe.Q[4],IP_Evaporator.TwoPhaseFlowPipe.Q[3],IP_Evaporator.TwoPhaseFlowPipe.Q[2],IP_Evaporator.TwoPhaseFlowPipe.Q[1],IP_Evaporator.TwoPhaseFlowPipe.P[4],IP_Evaporator.TwoPhaseFlowPipe.P[3],IP_Evaporator.TwoPhaseFlowPipe.P[2],IP_Evaporator.ExchangerWall.Tp[3],IP_Evaporator.ExchangerWall.Tp[2],IP_Evaporator.ExchangerWall.Tp[1],IP_Drum.Vl,IP_Drum.Tp,IP_Drum.hv,IP_Drum.hl,IP_Drum.P,HP_SuperHeater_3.TwoPhaseFlowPipe.h[4],HP_SuperHeater_3.TwoPhaseFlowPipe.h[3],HP_SuperHeater_3.TwoPhaseFlowPipe.h[2],HP_SuperHeater_3.TwoPhaseFlowPipe.Q[4],HP_SuperHeater_3.TwoPhaseFlowPipe.Q[3],HP_SuperHeater_3.TwoPhaseFlowPipe.Q[2],HP_SuperHeater_3.TwoPhaseFlowPipe.P[4],HP_SuperHeater_3.TwoPhaseFlowPipe.P[3],HP_SuperHeater_3.TwoPhaseFlowPipe.P[2],HP_SuperHeater_3.ExchangerWall.Tp[3],HP_SuperHeater_3.ExchangerWall.Tp[2],HP_SuperHeater_3.ExchangerWall.Tp[1],HP_SuperHeater_2.TwoPhaseFlowPipe.h[4],HP_SuperHeater_2.TwoPhaseFlowPipe.h[3],HP_SuperHeater_2.TwoPhaseFlowPipe.h[2],HP_SuperHeater_2.TwoPhaseFlowPipe.Q[4],HP_SuperHeater_2.TwoPhaseFlowPipe.Q[3],HP_SuperHeater_2.TwoPhaseFlowPipe.Q[2],HP_SuperHeater_2.TwoPhaseFlowPipe.P[4],HP_SuperHeater_2.TwoPhaseFlowPipe.P[3],HP_SuperHeater_2.TwoPhaseFlowPipe.P[2],HP_SuperHeater_2.ExchangerWall.Tp[3],HP_SuperHeater_2.ExchangerWall.Tp[2],HP_SuperHeater_2.ExchangerWall.Tp[1],HP_Economizer_1.TwoPhaseFlowPipe.h[4],HP_Economizer_1.TwoPhaseFlowPipe.h[3],HP_Economizer_1.TwoPhaseFlowPipe.h[2],HP_Economizer_1.TwoPhaseFlowPipe.Q[4],HP_Economizer_1.TwoPhaseFlowPipe.Q[3],HP_Economizer_1.TwoPhaseFlowPipe.Q[2],HP_Economizer_1.TwoPhaseFlowPipe.Q[1],HP_Economizer_1.TwoPhaseFlowPipe.P[4],HP_Economizer_1.TwoPhaseFlowPipe.P[3],HP_Economizer_1.TwoPhaseFlowPipe.P[2],HP_Economizer_1.ExchangerWall.Tp[3],HP_Economizer_1.ExchangerWall.Tp[2],HP_Economizer_1.ExchangerWall.Tp[1],HP_Economizer_2.TwoPhaseFlowPipe.h[4],HP_Economizer_2.TwoPhaseFlowPipe.h[3],HP_Economizer_2.TwoPhaseFlowPipe.h[2],HP_Economizer_2.TwoPhaseFlowPipe.Q[4],HP_Economizer_2.TwoPhaseFlowPipe.Q[3],HP_Economizer_2.TwoPhaseFlowPipe.Q[2],HP_Economizer_2.TwoPhaseFlowPipe.Q[1],HP_Economizer_2.TwoPhaseFlowPipe.P[4],HP_Economizer_2.TwoPhaseFlowPipe.P[3],HP_Economizer_2.TwoPhaseFlowPipe.P[2],HP_Economizer_2.ExchangerWall.Tp[3],HP_Economizer_2.ExchangerWall.Tp[2],HP_Economizer_2.ExchangerWall.Tp[1],HP_Economizer_3.TwoPhaseFlowPipe.h[4],HP_Economizer_3.TwoPhaseFlowPipe.h[3],HP_Economizer_3.TwoPhaseFlowPipe.h[2],HP_Economizer_3.TwoPhaseFlowPipe.Q[3],HP_Economizer_3.TwoPhaseFlowPipe.Q[2],HP_Economizer_3.TwoPhaseFlowPipe.Q[1],HP_Economizer_3.TwoPhaseFlowPipe.P[4],HP_Economizer_3.TwoPhaseFlowPipe.P[3],HP_Economizer_3.TwoPhaseFlowPipe.P[2],HP_Economizer_3.ExchangerWall.Tp[3],HP_Economizer_3.ExchangerWall.Tp[2],HP_Economizer_3.ExchangerWall.Tp[1],HP_SuperHeater_1.TwoPhaseFlowPipe.h[4],HP_SuperHeater_1.TwoPhaseFlowPipe.h[3],HP_SuperHeater_1.TwoPhaseFlowPipe.h[2],HP_SuperHeater_1.TwoPhaseFlowPipe.Q[4],HP_SuperHeater_1.TwoPhaseFlowPipe.Q[3],HP_SuperHeater_1.TwoPhaseFlowPipe.Q[2],HP_SuperHeater_1.TwoPhaseFlowPipe.Q[1],HP_SuperHeater_1.TwoPhaseFlowPipe.P[4],HP_SuperHeater_1.TwoPhaseFlowPipe.P[3],HP_SuperHeater_1.TwoPhaseFlowPipe.P[2],HP_SuperHeater_1.ExchangerWall.Tp[3],HP_SuperHeater_1.ExchangerWall.Tp[2],HP_SuperHeater_1.ExchangerWall.Tp[1],HP_Economizer_4.TwoPhaseFlowPipe.h[4],HP_Economizer_4.TwoPhaseFlowPipe.h[3],HP_Economizer_4.TwoPhaseFlowPipe.h[2],HP_Economizer_4.TwoPhaseFlowPipe.Q[4],HP_Economizer_4.TwoPhaseFlowPipe.Q[3],HP_Economizer_4.TwoPhaseFlowPipe.Q[2],HP_Economizer_4.TwoPhaseFlowPipe.Q[1],HP_Economizer_4.TwoPhaseFlowPipe.P[4],HP_Economizer_4.TwoPhaseFlowPipe.P[3],HP_Economizer_4.TwoPhaseFlowPipe.P[2],HP_Economizer_4.ExchangerWall.Tp[3],HP_Economizer_4.ExchangerWall.Tp[2],HP_Economizer_4.ExchangerWall.Tp[1],HP_Evaporator.TwoPhaseFlowPipe.h[4],HP_Evaporator.TwoPhaseFlowPipe.h[3],HP_Evaporator.TwoPhaseFlowPipe.h[2],HP_Evaporator.TwoPhaseFlowPipe.Q[4],HP_Evaporator.TwoPhaseFlowPipe.Q[3],HP_Evaporator.TwoPhaseFlowPipe.Q[2],HP_Evaporator.TwoPhaseFlowPipe.Q[1],HP_Evaporator.TwoPhaseFlowPipe.P[4],HP_Evaporator.TwoPhaseFlowPipe.P[3],HP_Evaporator.TwoPhaseFlowPipe.P[2],HP_Evaporator.ExchangerWall.Tp[3],HP_Evaporator.ExchangerWall.Tp[2],HP_Evaporator.ExchangerWall.Tp[1],VolumeEvapHP.h,HP_Drum.Vl,HP_Drum.Tp,HP_Drum.hv,HP_Drum.hl,HP_Drum.P) * Number of discrete variables: 9 ($whenCondition1,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (4855): * Single equations (assignments): 4403 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 266 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 7 * Torn equation systems: 172 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 5 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 2 systems {1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 65 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 107 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,15), (1,6), (1,15), (1,6), (1,5), (1,2), (1,2), (1,3), (1,2), (1,2), (1,6), (13,70), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,6), (1,6), (1,6), (1,15), (1,15), (1,6), (1,6), (1,6), (1,5), (1,3), (6,14), (1,3), (6,14), (1,3), (1,3), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (5,14), (1,1), (1,5), (1,3), (8,15), (4,20), (1,3), (1,4), (4,22), (1,4), (1,4)} Notification: Performance of Backend phase and start with SimCode phase: time 0.7857/16.4, allocations: 220.7 MB / 6.221 GB, free: 295.7 MB / 0.9481 GB Notification: Performance of simCode: created initialization part: time 0.2585/16.66, allocations: 176.6 MB / 6.394 GB, free: 182.4 MB / 0.9481 GB Notification: Performance of simCode: created event and clocks part: time 1.255e-05/16.66, allocations: 7.625 kB / 6.394 GB, free: 182.3 MB / 0.9481 GB Notification: Performance of simCode: created simulation system equations: time 0.1435/16.81, allocations: 82.7 MB / 6.475 GB, free: 98.11 MB / 0.9481 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.0819/16.89, allocations: 15.68 MB / 6.49 GB, free: 83.69 MB / 0.9481 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 2.77/19.66, allocations: 0.6239 GB / 7.114 GB, free: 250.7 MB / 0.9481 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.04053/19.7, allocations: 24.5 MB / 7.138 GB, free: 233.1 MB / 0.9481 GB Notification: Performance of simCode: alias equations: time 0.04304/19.74, allocations: 8.429 MB / 7.146 GB, free: 227.9 MB / 0.9481 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.03909/19.78, allocations: 22.28 MB / 7.168 GB, free: 207.1 MB / 0.9481 GB Notification: Performance of SimCode: time 2.264e-06/19.78, allocations: 0 / 7.168 GB, free: 207.1 MB / 0.9481 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 4.048/23.83, allocations: 1.897 GB / 9.065 GB, free: 208.4 MB / 0.9481 GB Notification: Performance of buildModelFMU: Generate platform static: time 342.9/366.7, allocations: 6.719 kB / 9.065 GB, free: 208.4 MB / 0.9481 GB " [Timeout remaining time 292] (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation.pipe >> ../files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation.sim & (cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation_fmu --startTime=0 --stopTime=2500 --stepSize=1 --mode=me --timeout=360 --tolerance=1e-06 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation.pipe 2>&1) [Timeout 378.0] OMSimulator failed or timed out simulating it; the others still get to run it (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-cvode.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-cvode.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-cvode.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-cvode.sim & (cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=2500 --stepSize=1 --mode=cs --timeout=360 --tolerance=1e-06 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation_OMSimulator-cs-cvode.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-cvode.pipe 2>&1) [Timeout 378.0] OMSimulator-cs-cvode timed out simulating the FMU (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-euler.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-euler.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-euler.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-euler.sim & (cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=2500 --stepSize=1 --mode=cs --timeout=360 --tolerance=1e-06 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation_OMSimulator-cs-euler.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_OMSimulator-cs-euler.pipe 2>&1) [Timeout 378.0] OMSimulator-cs-euler timed out simulating the FMU (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_fmpy.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_fmpy.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_fmpy.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_fmpy.sim & (cd run_fmpy && python3 -m fmpy simulate --output-file ../ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_fmpy_res.csv --start-time 0 --stop-time 2500 --timeout 360 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 1 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_LoadVariation.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation_fmpy.pipe 2>&1) [Timeout 378.0] fmpy timed out simulating the FMU [Calling sys.exit(0), Time elapsed: 471.42053738608956]