(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=10000 --stepSize=4 --mode=cs --timeout=240 --tolerance=1e-06 ../IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : IDEAS.Fluid.HeatPumps.Examples.HeatPump_perfFromTout (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10000.000000 - tolerance : 1e-06 - stepSize : 4 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump3.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump3: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump4.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump4: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump5.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump5: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump6.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump6: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump7.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_perfFromTout.pump7: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: Result file: IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter HeatPump_perfFromTout.HP.copTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP.powerTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom.copTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom.powerTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom_recomp.copTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom_recomp.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom_recomp.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom_recomp.powerTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom_recomp.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_nom_recomp.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_recomp.copTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_recomp.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_recomp.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_recomp.powerTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_recomp.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_perfFromTout.HP_recomp.powerTable.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Media/package.mo:5926:7-5930:3:writable] | | | | The following assertion has been violated at time 4.000000 | | | | ((HP_nom_recomp.vol2.dynBal.medium.T >= 272.15 and HP_nom_recomp.vol2.dynBal.medium.T <= 403.15)) --> " | | | | Temperature T (= 248.046 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". | | | | " error: [fmi2logger] [fmi2Error] HeatPump_perfFromTout/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "HeatPump_perfFromTout.root.HeatPump_perfFromTout" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Media/package.mo:5926:7-5930:3:writable] | | | | The following assertion has been violated at time 4.000000 | | | | ((HP_nom_recomp.vol2.dynBal.medium.T >= 272.15 and HP_nom_recomp.vol2.dynBal.medium.T <= 403.15)) --> " | | | | Temperature T (= 248.046 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". | | | | " error: [fmi2logger] [fmi2Error] HeatPump_perfFromTout/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sine1.continuous Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 4 errors