(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_IDEAS_IDEAS_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-08 ../IDEAS_IDEAS_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-08 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : IDEAS.Fluid.HeatPumps.ModularReversible.Examples.Modular_OneRoomRadiator (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-08 - stepSize : 34.56 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 4.0.0/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:158:3-163:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((heaPum.refCyc.refCycHeaPumCoo.mEva_flow_nominal <= heaPum.refCyc.refCycHeaPumCoo.mEva_flow_max)) --> "In Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal evaporator mass flow rate (5.58642 kg/s) is bigger than the | | | | maximal value (3.76014 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." info: Result file: IDEAS_IDEAS_Fluid_HeatPumps_ModularReversible_Examples_Modular_OneRoomRadiator_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.datTab.devIde will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.devIde will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabPEle.delimiter will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabPEle.fileName will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabPEle.tableName will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabQUse_flow.delimiter will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabQUse_flow.fileName will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo.tabQUse_flow.tableName will not be stored in the result file, because the signal type is not supported info: Variable Modular_OneRoomRadiator.heaPum.refCyc.refCycHeaPumHea.devIde will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapCoo.tabBou.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapCoo.tabBou.fileName will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapCoo.tabBou.tableName will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapHea.tabBou.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapHea.tabBou.fileName will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.heaPum.safCtr.opeEnv.bouMapHea.tabBou.tableName will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.timTab.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.timTab.fileName will not be stored in the result file, because the signal type is not supported info: Parameter Modular_OneRoomRadiator.timTab.tableName will not be stored in the result file, because the signal type is not supported