(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_Schedule_EquipmentScheduleOutputVariable_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_Schedule_EquipmentScheduleOutputVariable_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.Schedule.EquipmentScheduleOutputVariable (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 172800.000000 - tolerance : 1e-06 - stepSize : 69.12 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.14 23:26 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output EquipmentScheduleOutputVariable.equEle.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_Schedule_EquipmentScheduleOutputVariable_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter EquipmentScheduleOutputVariable.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter EquipmentScheduleOutputVariable.equEle.key will not be stored in the result file, because the signal type is not supported info: Parameter EquipmentScheduleOutputVariable.equEle.name will not be stored in the result file, because the signal type is not supported info: Parameter EquipmentScheduleOutputVariable.schInt.name will not be stored in the result file, because the signal type is not supported info: Parameter EquipmentScheduleOutputVariable.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Utilities/Diagnostics/AssertEquality.mo:6:5-11:47:writable] | | | | The following assertion has been violated at time 25200.000000 | | | | ((if noEvent(time > assEqu.t0) then noEvent(abs(equEle.y - assEqu.u2) < assEqu.threShold) else true)) --> "EnergyPlus did not synchronize the output variable correctly | | | | time = 25200 | | | | u1 = 0 | | | | u2 = 500 | | | | abs(u1-u2) = 500 | | | | threShold = 1e-06" error: [fmi2logger] [fmi2Error] EquipmentScheduleOutputVariable/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "EquipmentScheduleOutputVariable.root.EquipmentScheduleOutputVariable" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Utilities/Diagnostics/AssertEquality.mo:6:5-11:47:writable] | | | | The following assertion has been violated at time 25200.000000 | | | | ((if noEvent(time > assEqu.t0) then noEvent(abs(equEle.y - assEqu.u2) < assEqu.threShold) else true)) --> "EnergyPlus did not synchronize the output variable correctly | | | | time = 25200 | | | | u1 = 0 | | | | u2 = 500 | | | | abs(u1-u2) = 500 | | | | threShold = 1e-06" error: [fmi2logger] [fmi2Error] EquipmentScheduleOutputVariable/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable zon.use_C_flow Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)