(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIDControlAutoTuning_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIDControlAutoTuning_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3600.000000 - tolerance : 1e-06 - stepSize : 1.44 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOnRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOnRec.yRec.y, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOffRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOffRec.yRec.y, has value: 0" info: Result file: Buildings_13_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIDControlAutoTuning_OMSimulator-cs-cvode_res.mat (bufferSize=10) LOG_ASSERT | debug | division by zero at time 2178.720000000062, (a=1) / (b=0), where divisor b expression is: con.conProMod.addPar.y error: [fmi2logger] [fmi2Error] WetCoilCounterFlowPIDControlAutoTuning/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "WetCoilCounterFlowPIDControlAutoTuning.root.WetCoilCounterFlowPIDControlAutoTuning" LOG_ASSERT | debug | division by zero at time 2178.720000000062, (a=1) / (b=0), where divisor b expression is: con.conProMod.addPar.y error: [fmi2logger] [fmi2Error] WetCoilCounterFlowPIDControlAutoTuning/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable con.triTun Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 4 errors