(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuning (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3600.000000 - tolerance : 1e-06 - stepSize : 1.44 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOnRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOnRec.yRec.y, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOffRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOffRec.yRec.y, has value: 0" info: Result file: Buildings_13_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning_OMSimulator-cs-cvode_res.mat (bufferSize=10) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 2175.840000 | | | | ((con.conProMod.not1.y)) --> "Autotuning failed. The controller gains are unchanged." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 2175.840000 | | | | ((con.resPro.norTimDel.or2.y)) --> "Warning: The asymmetry level of the relay controller is lower than the half period ratio. Increase the asymmetry level."