(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Applications_DataCenters_DXCooled_Examples_DXCooledAirsideEconomizer_OMSimulator-cs-cvode_fmu --startTime=1.188e+07 --stopTime=1.26e+07 --stepSize=288 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Applications_DataCenters_DXCooled_Examples_DXCooledAirsideEconomizer_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.Applications.DataCenters.DXCooled.Examples.DXCooledAirsideEconomizer (co-simulation) - fmiVersion: 2.0 - startTime : 11880000.000000 - stopTime : 12600000.000000 - tolerance : 1e-06 - stepSize : 288 LOG_NLS | error | residualFunc1329: Iteration variable ``pŽ` is inf or nan. LOG_ASSERT | debug | residualFunc1329 failed at time=11880000. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_NLS | error | residualFunc1329: Iteration variable `` is inf or nan. LOG_ASSERT | debug | residualFunc1329 failed at time=11880000. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc1329: Iteration variable ``pŽ` is inf or nan. LOG_ASSERT | debug | residualFunc1329 failed at time=11880000. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc1329: Iteration variable ``pŽ` is inf or nan. LOG_ASSERT | debug | residualFunc1329 failed at time=11880000. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc1329: Iteration variable ``pŽ` is inf or nan. LOG_ASSERT | debug | residualFunc1329 failed at time=11880000. | | | | For more information please use -lv LOG_NLS. warning: [fmi2Warning] DXCooledAirsideEconomizer/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Functions/warnIfPerformanceOutOfBounds.mo:18: *** Warning: DX coil performance curves at nominal conditions are outside of bounds. Capacity as a function of temperature is outside of bounds 0.9 to 1.1. The value of the curve fit is 1.21996 Check the coefficients of the function sta[1].perCur.capFunT. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 11880000.000000 | | | | ((varSpeDX.watVapEva.nomVal.gamma <= varSpeDX.watVapEva.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.693093, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 82.8363 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.0088221 - 0.00965846 = -0.000836363 | | | | QLat_flow_nominal = -200000 | | | | " LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 11880000.000000 | | | | ((fan.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan.etaHyd, has value: -4.23516e-21" info: Result file: Buildings_13_Buildings_Applications_DataCenters_DXCooled_Examples_DXCooledAirsideEconomizer_OMSimulator-cs-cvode_res.mat (bufferSize=10) Segmentation fault (core dumped)