(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalTwoZoneBuildings_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_MultipleBuildings_TwoIdenticalTwoZoneBuildings_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_MultipleBuildings_TwoIdenticalTwoZoneBuildings_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalTwoZoneBuildings (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 172800.000000 - tolerance : 1e-06 - stepSize : 69.12 LOG_STDOUT | info | ... loading "EnergyPlus" from "/tmp/tmpqfist7j8/TwoIdenticalTwoZoneBuildings-2pb9t3ex/temp/0001_TwoIdenticalTwoZoneBuildings/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Resources/Data/ThermalZones/EnergyPlus_24_2_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" LOG_STDOUT | info | ... loading "EnergyPlus" from "/tmp/tmpqfist7j8/TwoIdenticalTwoZoneBuildings-2pb9t3ex/temp/0001_TwoIdenticalTwoZoneBuildings/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Resources/Data/ThermalZones/EnergyPlus_24_2_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.15 00:20 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output TwoIdenticalTwoZoneBuildings.bui.inf1.y has in Modelica the unit 1. info: Result file: ../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalTwoZoneBuildings_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter TwoIdenticalTwoZoneBuildings.bui[1].datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[2].datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[1].datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[2].datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[1].inf1.key will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[2].inf1.key will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[1].inf1.name will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[2].inf1.name will not be stored in the result file, because the signal type is not supported info: Variable TwoIdenticalTwoZoneBuildings.bui[1].zon1.zon.zoneName will not be stored in the result file, because the signal type is not supported info: Variable TwoIdenticalTwoZoneBuildings.bui[2].zon1.zon.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[1].zon1.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[2].zon1.zoneName will not be stored in the result file, because the signal type is not supported info: Variable TwoIdenticalTwoZoneBuildings.bui[1].zon2.zon.zoneName will not be stored in the result file, because the signal type is not supported info: Variable TwoIdenticalTwoZoneBuildings.bui[2].zon2.zon.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[1].zon2.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalTwoZoneBuildings.bui[2].zon2.zoneName will not be stored in the result file, because the signal type is not supported Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.24sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 172247.040 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172247.040 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172247.040 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172247.040 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172247.040 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172247.040 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. Segmentation fault (core dumped)