Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.5691/0.5691, allocations: 120.4 MB / 140.2 MB, free: 12.98 MB / 138.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding") translateModel(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 3.337e-06/3.337e-06, allocations: 0 / 218 MB, free: 8.621 MB / 202.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 4.259e-05/4.593e-05, allocations: 2.281 kB / 218 MB, free: 8.617 MB / 202.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding): time 1.014/1.014, allocations: 264.4 MB / 482.4 MB, free: 14.71 MB / 442.7 MB Notification: Performance of NFInst.instExpressions: time 0.3819/1.395, allocations: 169.8 MB / 0.6369 GB, free: 11.46 MB / 0.573 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.002613/1.398, allocations: 47.81 kB / 0.637 GB, free: 11.41 MB / 0.573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:178:3-180:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:181:3-183:56:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:194:3-196:48:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:80:3-81:83:writable] Warning: Connector C1vap is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:82:3-84:16:writable] Warning: Connector C2ex is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:85:3-87:24:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:88:3-90:17:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:95:3-97:17:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/Sink.mo:17:3-19:16:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:15:3-17:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:18:3-19:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:22:3-23:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:24:3-25:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001516/1.4, allocations: 0.9057 MB / 0.6379 GB, free: 10.51 MB / 0.573 GB Notification: Performance of NFTyping.typeBindings: time 0.003122/1.403, allocations: 2.131 MB / 0.64 GB, free: 8.363 MB / 0.573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.031/1.434, allocations: 13.72 MB / 0.6534 GB, free: 10.65 MB / 0.5886 GB Notification: Performance of NFFlatten.flatten: time 0.01785/1.452, allocations: 26.69 MB / 0.6794 GB, free: 15.89 MB / 0.6198 GB Notification: Performance of NFFlatten.resolveConnections: time 0.009729/1.461, allocations: 7.273 MB / 0.6865 GB, free: 8.527 MB / 0.6198 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01833/1.48, allocations: 11.9 MB / 0.6981 GB, free: 12.61 MB / 0.6355 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01138/1.491, allocations: 7.711 MB / 0.7057 GB, free: 4.883 MB / 0.6355 GB Notification: Performance of NFPackage.collectConstants: time 0.005054/1.496, allocations: 1.797 MB / 0.7074 GB, free: 3.086 MB / 0.6355 GB Notification: Performance of NFFlatten.collectFunctions: time 0.03672/1.533, allocations: 21.57 MB / 0.7285 GB, free: 13.48 MB / 0.6667 GB Notification: Performance of NFScalarize.scalarize: time 0.007571/1.54, allocations: 6.057 MB / 0.7344 GB, free: 7.41 MB / 0.6667 GB Notification: Performance of NFVerifyModel.verify: time 0.01122/1.552, allocations: 6.262 MB / 0.7405 GB, free: 1.137 MB / 0.6667 GB Notification: Performance of NFConvertDAE.convert: time 0.3456/1.897, allocations: 36.4 MB / 0.7761 GB, free: 53.74 MB / 0.6667 GB Notification: Performance of FrontEnd - DAE generated: time 6.873e-06/1.897, allocations: 0 / 0.7761 GB, free: 53.74 MB / 0.6667 GB Notification: Performance of FrontEnd: time 1.884e-06/1.897, allocations: 0 / 0.7761 GB, free: 53.74 MB / 0.6667 GB Notification: Performance of Transformations before backend: time 0.0007357/1.898, allocations: 0.6562 kB / 0.7761 GB, free: 53.74 MB / 0.6667 GB Error: Too few equations, under-determined system. The model has 3749 equation(s) and 3751 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/InstrumentationAndControl/Connectors.mo:52:5-52:22:writable] Warning: Variable regulation_Niveau.MesureDebitVapeur.signal does not have any remaining equation to be solved in. The original equations were: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/InstrumentationAndControl/Connectors.mo:52:5-52:22:writable] Warning: Variable regulation_Niveau.MesureDebitEau.signal does not have any remaining equation to be solved in. The original equations were: " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 3.2171550784260035] Failed to read output from testmodel.py, exit status != 0: 2.237888920120895 2.122925259 0.22412055 Calling exit ...