Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermalSeparation_ThermalSeparation.Examples.Testing.Complex.CycleComplex.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0007867/0.0007867, allocations: 84.44 kB / 20.69 MB, free: 3.871 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001032/0.001032, allocations: 165.9 kB / 23.96 MB, free: 0.5977 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.8752/0.8752, allocations: 177.1 MB / 204.3 MB, free: 5.738 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo): time 0.3331/0.3331, allocations: 50.76 MB / 311.5 MB, free: 5.188 MB / 282.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:146:3-158:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:160:3-168:15:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:145:4-157:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:159:5-167:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:320:4-332:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:334:5-342:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 180] Using package ThermalSeparation with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(ThermalSeparation.Examples.Testing.Complex.CycleComplex,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Testing.Complex.CycleComplex") translateModel(ThermalSeparation.Examples.Testing.Complex.CycleComplex,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Testing.Complex.CycleComplex") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.824e-06/1.824e-06, allocations: 0 / 463.3 MB, free: 29.52 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.686e-05/1.869e-05, allocations: 4.531 kB / 463.3 MB, free: 29.52 MB / 410.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Media/IdealGasMixtures/BaseClasses/BaseIdealGasMixture.mo:32:3-34:73:writable] Error: BaseIdealGasMixture is partial, name lookup is not allowed in partial classes. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Columns/BaseClasses/BaseColumn.mo:75:2-75:113:writable] Error: Class MediumVapour.BaseProperties not found in scope BaseColumn. Notification: Performance of FrontEnd: time 0.1049/0.1049, allocations: 117.3 MB / 0.5669 GB, free: 0.7305 MB / 474.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.075798640958965] Failed to read output from testmodel.py, exit status != 0: 0.10950788576155901 0.11761600400000001 -1.0 Calling exit ...