Environment - simulationEnvironment: startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0008 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetworkDelayed_N_640_M_10 -emit_protected Breaker 640 opens at time = 0.406465 Breaker 639 opens at time = 0.406856 Breaker 638 opens at time = 0.407465 Breaker 637 opens at time = 0.407644 Breaker 636 opens at time = 0.407856 Breaker 635 opens at time = 0.408437 Breaker 634 opens at time = 0.408465 Breaker 633 opens at time = 0.408644 Breaker 632 opens at time = 0.408856 Breaker 631 opens at time = 0.409248