Environment - simulationEnvironment: startTime=-1 stopTime=1 tolerance=1e-06 numberOfIntervals=200 stepSize=0.01 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step10VaporQualityPseudoInversion -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((condenser.p_min >= 611.657 and condenser.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= condenser.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((superheater.p_min >= 611.657 and superheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= superheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((preheater.p_min >= 611.657 and preheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((boiler.p_min >= 611.657 and boiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= boiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00927841s reading init.xml | | | | | | 0.000530685s reading info.xml | | | | | | 0.0102837s [ 9.6%] pre-initialization | | | | | | 0.000785974s [ 0.7%] initialization | | | | | | 0.000169629s [ 0.2%] steps | | | | | | 0.000575557s [ 0.5%] solver (excl. callbacks) | | | | | | 0.000975947s [ 0.9%] creating output-file | | | | | | 0.000836336s [ 0.8%] event-handling | | | | | | 0.00125167s [ 1.2%] overhead | | | | | | 0.0920533s [ 86.1%] simulation | | | | | | 0.106932s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 351 steps taken | | | | | | 487 calls of functionODE | | | | | | 95 evaluations of jacobian | | | | | | 18 error test failures | | | | | | 6 convergence test failures | | | | | | 0.00892503s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.