Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.02 Regular simulation: ./ThermofluidStream_ThermofluidStream.Undirected.FlowControl.Tests.ValveReferenceValues_Undirected -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/BasicControlValve.mo:42:5-48:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues_Undirected.dp_ref": dp_ref must remain at its default value of 1 bar when m_flow_ref_set is not used. Modifying dp_ref leads to incorrect model behavior. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/BasicControlValve.mo:50:5-56:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues_Undirected.rho_ref": rho_ref must remain at its default value of 1000 kg/m3 when m_flow_ref_set is not used. Modifying rho_ref leads to incorrect model behavior. Remove the rho_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/SpecificValveType.mo:56:5-62:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref1.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues_Undirected.dp_ref1": dp_ref must remain at its default value of 1 bar when using Kvs, Cvs_US, or Cvs_UK. Modifying dp_ref leads to incorrect model behavior. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/SpecificValveType.mo:64:5-70:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref1.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues_Undirected.rho_ref1": rho_ref must remain at its default value of 1000 kg/m3 when using Kvs, Cvs_US, or Cvs_UK. Modifying rho_ref leads to incorrect model behavior. Remove the rho_ref modifier." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.012612s reading init.xml | | | | | | 0.000922351s reading info.xml | | | | | | 0.0236434s [ 65.9%] pre-initialization | | | | | | 0.000332403s [ 0.9%] initialization | | | | | | 3.967e-06s [ 0.0%] steps | | | | | | 0.000590549s [ 1.6%] solver (excl. callbacks) | | | | | | 0.00181614s [ 5.1%] creating output-file | | | | | | 0.000155581s [ 0.4%] event-handling | | | | | | 0.00219527s [ 6.1%] overhead | | | | | | 0.00713299s [ 19.9%] simulation | | | | | | 0.0358703s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 437 steps taken | | | | | | 778 calls of functionODE | | | | | | 148 evaluations of jacobian | | | | | | 46 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000438372s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.