Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.2 Regular simulation: ./ThermofluidStream_ThermofluidStream.Examples.ReverseHeatPump -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/Boundaries/PhaseSeparator.mo:41:3-41:139:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((accumulator.x >= 0.0 and accumulator.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= accumulator.x <= 1.0, has value: 1.28662" LOG_ASSERT | debug | Solving non-linear system 2665 failed at time=12.0774859163771. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2717 failed at time=12.0774859163771. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2717 failed at time=12.0203562932873. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 78.400000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 78.400000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 78.400000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 78.400000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0541304s reading init.xml | | | | | | 0.00499639s reading info.xml | | | | | | 0.00159298s [ 0.0%] pre-initialization | | | | | | 0.0489834s [ 0.0%] initialization | | | | | | 0.0149421s [ 0.0%] steps | | | | | | 0.0764352s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00678396s [ 0.0%] creating output-file | | | | | | 45.5257s [ 17.2%] event-handling | | | | | | 0.0476712s [ 0.0%] overhead | | | | | | 219.178s [ 82.7%] simulation | | | | | | 264.9s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 3744 steps taken | | | | | | 5843 calls of functionODE | | | | | | 649 evaluations of jacobian | | | | | | 317 error test failures | | | | | | 6 convergence test failures | | | | | | 151.611s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.