Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.885/0.885, allocations: 153.8 MB / 172.7 MB, free: 4.832 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan") translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005741/0.0005741, allocations: 15.97 kB / 250.3 MB, free: 3.852 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1598/0.1604, allocations: 33.35 MB / 283.7 MB, free: 2.055 MB / 222.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan): time 1.92/2.081, allocations: 311.4 MB / 0.5811 GB, free: 16.96 MB / 478.1 MB Notification: Performance of NFInst.instExpressions: time 0.1659/2.247, allocations: 134.2 MB / 0.7122 GB, free: 11.1 MB / 0.5762 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0007802/2.247, allocations: 8 kB / 0.7122 GB, free: 11.09 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:48:3-50:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:51:3-52:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:53:3-55:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:56:3-57:83:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.000708/2.248, allocations: 227 kB / 0.7124 GB, free: 10.88 MB / 0.5762 GB Notification: Performance of NFTyping.typeBindings: time 0.001162/2.249, allocations: 491.4 kB / 0.7129 GB, free: 10.39 MB / 0.5762 GB Notification: Performance of NFTyping.typeClassSections: time 0.003836/2.253, allocations: 1.516 MB / 0.7143 GB, free: 8.871 MB / 0.5762 GB Notification: Performance of NFFlatten.flatten: time 0.003008/2.256, allocations: 2.385 MB / 0.7167 GB, free: 6.48 MB / 0.5762 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001422/2.258, allocations: 1.029 MB / 0.7177 GB, free: 5.418 MB / 0.5762 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001096/2.259, allocations: 0.9153 MB / 0.7186 GB, free: 4.5 MB / 0.5762 GB Notification: Performance of NFSimplifyModel.simplify: time 0.001165/2.26, allocations: 0.8988 MB / 0.7195 GB, free: 3.598 MB / 0.5762 GB Notification: Performance of NFPackage.collectConstants: time 0.0003281/2.26, allocations: 251.9 kB / 0.7197 GB, free: 3.352 MB / 0.5762 GB Notification: Performance of NFFlatten.collectFunctions: time 0.002498/2.263, allocations: 1.116 MB / 0.7208 GB, free: 2.234 MB / 0.5762 GB Notification: Performance of NFScalarize.scalarize: time 0.0004843/2.263, allocations: 0.5063 MB / 0.7213 GB, free: 1.727 MB / 0.5762 GB Notification: Performance of NFVerifyModel.verify: time 0.0009366/2.264, allocations: 0.8793 MB / 0.7221 GB, free: 0.8438 MB / 0.5762 GB Notification: Performance of NFConvertDAE.convert: time 0.003622/2.268, allocations: 2.914 MB / 0.725 GB, free: 13.92 MB / 0.5919 GB Notification: Performance of FrontEnd - DAE generated: time 3.917e-06/2.268, allocations: 4.5 kB / 0.725 GB, free: 13.92 MB / 0.5919 GB Notification: Performance of FrontEnd: time 1.553e-06/2.268, allocations: 4 kB / 0.725 GB, free: 13.91 MB / 0.5919 GB Notification: Performance of Transformations before backend: time 3.086e-05/2.268, allocations: 0 / 0.725 GB, free: 13.91 MB / 0.5919 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 509 * Number of variables: 509 Notification: Performance of Generate backend data structure: time 0.00451/2.272, allocations: 2.216 MB / 0.7272 GB, free: 11.66 MB / 0.5919 GB Notification: Performance of prepare preOptimizeDAE: time 3.886e-05/2.272, allocations: 12.03 kB / 0.7272 GB, free: 11.65 MB / 0.5919 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003862/2.273, allocations: 227.7 kB / 0.7274 GB, free: 11.43 MB / 0.5919 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.001159/2.274, allocations: 0.6741 MB / 0.728 GB, free: 10.72 MB / 0.5919 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001916/2.274, allocations: 203.4 kB / 0.7282 GB, free: 10.51 MB / 0.5919 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0004734/2.274, allocations: 216 kB / 0.7284 GB, free: 10.3 MB / 0.5919 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.004093/2.279, allocations: 2.432 MB / 0.7308 GB, free: 7.695 MB / 0.5919 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.603e-05/2.279, allocations: 7.938 kB / 0.7308 GB, free: 7.688 MB / 0.5919 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001698/2.279, allocations: 80 kB / 0.7309 GB, free: 7.609 MB / 0.5919 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 4.797e-05/2.279, allocations: 55.94 kB / 0.731 GB, free: 7.555 MB / 0.5919 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.003941/2.283, allocations: 2.074 MB / 0.733 GB, free: 5.477 MB / 0.5919 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.01101/2.294, allocations: 8.313 MB / 0.7411 GB, free: 12.96 MB / 0.6075 GB Notification: Performance of preOpt comSubExp (simulation): time 0.002104/2.296, allocations: 1.021 MB / 0.7421 GB, free: 11.93 MB / 0.6075 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.001409/2.297, allocations: 0.7678 MB / 0.7428 GB, free: 11.16 MB / 0.6075 GB Notification: Performance of preOpt evalFunc (simulation): time 0.000561/2.298, allocations: 188.8 kB / 0.743 GB, free: 10.98 MB / 0.6075 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.001547/2.299, allocations: 0.7953 MB / 0.7438 GB, free: 10.17 MB / 0.6075 GB Notification: Performance of pre-optimization done (n=129): time 4.038e-06/2.299, allocations: 0.6562 kB / 0.7438 GB, free: 10.17 MB / 0.6075 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=214): time 0.1789/2.478, allocations: 31.99 MB / 0.775 GB, free: 10.23 MB / 0.6387 GB " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 4.1952079720795155] Failed to read output from testmodel.py, exit status != 0: 2.8139360565692186 2.824776903 0.5543165999999999 Calling exit ...