Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.004 Regular simulation: ./ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSteamDryer -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00349758s reading init.xml | | | | | | 0.000257863s reading info.xml | | | | | | 5.7868e-05s [ 0.0%] pre-initialization | | | | | | 0.00148836s [ 0.6%] initialization | | | | | | 8.548e-05s [ 0.0%] steps | | | | | | 1.7857e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | -2.09111e-21s [ -0.0%] event-handling | | | | | | 0.00883184s [ 3.7%] overhead | | | | | | 0.227374s [ 95.6%] simulation | | | | | | 0.237866s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2500 steps taken | | | | | | 2500 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.