Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=0.0001 numberOfIntervals=5000 stepSize=2e-05 Regular simulation: ./Modelica_trunk_Modelica.Magnetic.FluxTubes.Examples.Hysteresis.SinglePhaseTransformerWithHysteresis2 -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00357927s reading init.xml | | | | | | 0.000252123s reading info.xml | | | | | | 0.000279965s [ 0.3%] pre-initialization | | | | | | 0.000159089s [ 0.2%] initialization | | | | | | 1.2303e-05s [ 0.0%] steps | | | | | | 0.00660493s [ 8.1%] solver (excl. callbacks) | | | | | | 0.00133852s [ 1.6%] creating output-file | | | | | | 0.0285983s [ 35.1%] event-handling | | | | | | 0.000969171s [ 1.2%] overhead | | | | | | 0.0435995s [ 53.5%] simulation | | | | | | 0.0815618s [100.0%] total | | | | | events | | | | | | 83 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 7988 steps taken | | | | | | 13570 calls of functionODE | | | | | | 1563 evaluations of jacobian | | | | | | 874 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00799578s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.