Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-08 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./IDEAS_dev_IDEAS.Fluid.HeatExchangers.Examples.WaterCooler_T -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0105373s reading init.xml | | | | | | 0.000855996s reading info.xml | | | | | | 7.7054e-05s [ 0.3%] pre-initialization | | | | | | 0.000252434s [ 1.1%] initialization | | | | | | 1.663e-06s [ 0.0%] steps | | | | | | 0.00327205s [ 14.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000589574s [ 2.6%] event-handling | | | | | | 0.00343354s [ 15.2%] overhead | | | | | | 0.0148988s [ 66.1%] simulation | | | | | | 0.0225251s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 4501 steps taken | | | | | | 6448 calls of functionODE | | | | | | 919 evaluations of jacobian | | | | | | 329 error test failures | | | | | | 19 convergence test failures | | | | | | 0.0031917s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.