Environment - simulationEnvironment: startTime=1e+07 stopTime=1.1e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=400 Regular simulation: ./IDEAS_IDEAS.Examples.Tutorial.Example8 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 10000000.000000 | | | | ((pumpSec.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 10000000.000000 | | | | ((pumpPrim.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/HeatPumps/BaseClasses/PartialWaterToWater.mo:84:3-89:58:writable] | | | | The following assertion has been violated at time 10098231.725445 | | | | ((heaPum.P >= 0.0)) --> "Variable violating min constraint: 0.0 <= heaPum.P, has value: -1.46937e-39" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/HeatPumps/BaseClasses/PartialWaterToWater.mo:91:3-96:60:writable] | | | | The following assertion has been violated at time 10149498.170997 | | | | ((heaPum.QEva_flow <= 0.0)) --> "Variable violating max constraint: heaPum.QEva_flow <= 0.0, has value: 1.41966e-07" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.262206s reading init.xml | | | | | | 0.0178933s reading info.xml | | | | | | 0.000422342s [ 0.0%] pre-initialization | | | | | | 0.0332922s [ 0.1%] initialization | | | | | | 0.00126203s [ 0.0%] steps | | | | | | 1.2406s [ 2.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 11.3811s [ 25.3%] event-handling | | | | | | 0.0950029s [ 0.2%] overhead | | | | | | 32.2916s [ 71.7%] simulation | | | | | | 45.0432s [100.0%] total | | | | | events | | | | | | 1948 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 68591 steps taken | | | | | | 94493 calls of functionODE | | | | | | 25659 evaluations of jacobian | | | | | | 3502 error test failures | | | | | | 14 convergence test failures | | | | | | 20.5403s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.