Environment - simulationEnvironment: startTime=0 stopTime=1.728e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=691.2 Regular simulation: ./IDEAS_IDEAS.Examples.IBPSA.SingleZoneResidentialHydronicHeatPump -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pum.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 72000.000000 | | | | ((floHea.m_flow >= 0.0 and floHea.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= floHea.m_flow <= 1e5, has value: -1.37449e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 244800.000000 | | | | ((reaPHeaPum.y >= 0.0)) --> "Variable violating min constraint: 0.0 <= reaPHeaPum.y, has value: -7.52316e-37" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.208142s reading init.xml | | | | | | 0.0124947s reading info.xml | | | | | | 0.000405762s [ 0.0%] pre-initialization | | | | | | 0.0337775s [ 0.4%] initialization | | | | | | 0.00101366s [ 0.0%] steps | | | | | | 0.176722s [ 1.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.48423s [ 16.3%] event-handling | | | | | | 0.0487325s [ 0.5%] overhead | | | | | | 7.37349s [ 80.9%] simulation | | | | | | 9.11838s [100.0%] total | | | | | events | | | | | | 62 state events | | | | | | 481 time events | | | | | solver: dassl | | | | | | 16102 steps taken | | | | | | 22027 calls of functionODE | | | | | | 6277 evaluations of jacobian | | | | | | 646 error test failures | | | | | | 0 convergence test failures | | | | | | 5.41824s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.