Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001453/0.001453, allocations: 99.64 kB / 18.95 MB, free: 2.668 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001745/0.001745, allocations: 213.7 kB / 22.24 MB, free: 5.262 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.577/1.577, allocations: 230.6 MB / 256 MB, free: 7.793 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 3.422/3.422, allocations: 0.4892 GB / 0.7943 GB, free: 35.54 MB / 0.6231 GB " [Timeout remaining time 176] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR2|hrc.hrc.chi.COP",fileNamePrefix="Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR2|hrc.hrc.chi.COP",fileNamePrefix="Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002152/0.002152, allocations: 72.33 kB / 1.154 GB, free: 25.51 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4114/0.4136, allocations: 176.1 MB / 1.326 GB, free: 1.859 MB / 1.014 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller): time 0.1728/0.5864, allocations: 130.5 MB / 1.453 GB, free: 14.97 MB / 1.154 GB Notification: Performance of NFInst.instExpressions: time 0.06834/0.6547, allocations: 39.71 MB / 1.492 GB, free: 7.164 MB / 1.186 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01124/0.6659, allocations: 258.1 kB / 1.492 GB, free: 6.91 MB / 1.186 GB Notification: Performance of NFTyping.typeComponents: time 0.01494/0.6809, allocations: 4.501 MB / 1.496 GB, free: 2.391 MB / 1.186 GB Notification: Performance of NFTyping.typeBindings: time 0.02157/0.7025, allocations: 7.015 MB / 1.503 GB, free: 11.35 MB / 1.201 GB Notification: Performance of NFTyping.typeClassSections: time 0.0151/0.7176, allocations: 5.111 MB / 1.508 GB, free: 6.258 MB / 1.201 GB Notification: Performance of NFFlatten.flatten: time 0.05144/0.769, allocations: 31.53 MB / 1.539 GB, free: 6.684 MB / 1.232 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Validation/HeatRecoveryChiller.mo:154:3-155:89:writable] Error: Cannot connect expandable connector busPumHeaWatHrc with non-expandable connector bus.pumHeaWatHrc. Notification: Performance of FrontEnd: time 0.00287/0.7719, allocations: 0.724 MB / 1.54 GB, free: 5.91 MB / 1.232 GB " [Timeout remaining time 299] [Calling sys.exit(0), Time elapsed: 7.694830749183893] Failed to read output from testmodel.py, exit status != 0: 0.7808876559138298 0.79530096 -1.0 Calling exit ...