Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-07 numberOfIntervals=1440 stepSize=60 Regular simulation: ./AixLib_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpDirectCooling -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSubstationHeatPumpDirectCooling.DHCsubstationHeatingDirectCooling.pumHeaPri: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSubstationHeatPumpDirectCooling.DHCsubstationHeatingDirectCooling.pumCoo: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0319718s reading init.xml | | | | | | 0.00280657s reading info.xml | | | | | | 0.000146185s [ 0.5%] pre-initialization | | | | | | 0.000598823s [ 2.0%] initialization | | | | | | 7.033e-06s [ 0.0%] steps | | | | | | 0.00117742s [ 3.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000288956s [ 1.0%] event-handling | | | | | | 0.00654368s [ 21.7%] overhead | | | | | | 0.021429s [ 71.0%] simulation | | | | | | 0.0301911s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 560 steps taken | | | | | | 698 calls of functionODE | | | | | | 114 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00253496s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.