Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr AES_AES.ProcessComponents.Thermal.HVAC.ControlledLiquidHeater_ideal.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001319/0.001319, allocations: 108.3 kB / 19.73 MB, free: 1.898 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001491/0.001491, allocations: 213.8 kB / 23.01 MB, free: 4.992 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.579/1.579, allocations: 230.6 MB / 256.8 MB, free: 7.816 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo): time 0.1237/0.1237, allocations: 24.03 MB / 337.2 MB, free: 11.45 MB / 270.1 MB " [Timeout remaining time 180] Using package AES with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(AES.ProcessComponents.Thermal.HVAC.ControlledLiquidHeater_ideal,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="AES_AES.ProcessComponents.Thermal.HVAC.ControlledLiquidHeater_ideal") translateModel(AES.ProcessComponents.Thermal.HVAC.ControlledLiquidHeater_ideal,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="AES_AES.ProcessComponents.Thermal.HVAC.ControlledLiquidHeater_ideal") [Timeout 660] "Notification: AES requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002503/0.002503, allocations: 71.83 kB / 474.4 MB, free: 5.879 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.414/0.4165, allocations: 59.57 MB / 0.5214 GB, free: 10.47 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/Interfaces/flowTwoPorts_pwh.mo:4:3-4:45:writable] Error: The model can't be instantiated due to top-level outer element 'system', it may only be used as part of a simulation model. Notification: Performance of FrontEnd: time 0.00358/0.4201, allocations: 1.635 MB / 0.523 GB, free: 9.348 MB / 382.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.1030408311635256] Failed to read output from testmodel.py, exit status != 0: 0.42984532564878464 0.44501158300000004 -1.0 Calling exit ...