(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Components_Gas_Compressor_Check_TestValveAndCompressor_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --mode=me --timeout=240 --tolerance=1e-06 ../TransiEnt_TransiEnt_Components_Gas_Compressor_Check_TestValveAndCompressor.fmu) info: *** FMU Simulation Info *** - model : TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 2.88 LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt warning: [fmi2Warning] TestValveAndCompressor/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt warning: [fmi2Warning] TestValveAndCompressor/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | TILMedia-Error(TestValveAndCompressor.storage.storage.gasBulk, PRModel::TDew, mediumPointerID=0): Dew temperature calculation failed for p=100000, xi={0.72209, 0.139592, 0.0690145, 0.0192457, 0.0266501, 0.0234078, 2.08167e-17, }, Debug info: {D=0.10018, S=1000, dSdT=-1264.15, counter=100} LOG_ASSERT | debug | division leads to inf or nan at time 0, (a=10069.4) / (b=nan), where divisor b is: valveAndCompressor_dp1.split.mass error: [fmi2logger] [fmi2Error] TestValveAndCompressor/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "TestValveAndCompressor.root.TestValveAndCompressor" error: [initialize] Initialization of system "TestValveAndCompressor.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 175, in _runFMU fmu.initialize() ~~~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 887, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error info: 2 warnings info: 3 errors