Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001532/0.001532, allocations: 99.64 kB / 18.94 MB, free: 2.551 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001982/0.001982, allocations: 212.3 kB / 22.25 MB, free: 4.859 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.82/1.82, allocations: 230.6 MB / 256 MB, free: 7.809 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 1.216/1.216, allocations: 100.9 MB / 413.3 MB, free: 2.887 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.003798/0.003798, allocations: 87.09 kB / 0.5641 GB, free: 35.62 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2642/0.268, allocations: 74.61 MB / 0.6369 GB, free: 6.5 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling): time 1.123/1.391, allocations: 239.3 MB / 0.8707 GB, free: 11.59 MB / 0.6231 GB Notification: Performance of NFInst.instExpressions: time 0.01484/1.406, allocations: 5.082 MB / 0.8756 GB, free: 7.043 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.003057/1.409, allocations: 48.03 kB / 0.8757 GB, free: 7.023 MB / 0.6231 GB Notification: Performance of NFTyping.typeComponents: time 0.004181/1.413, allocations: 0.7154 MB / 0.8764 GB, free: 6.422 MB / 0.6231 GB Notification: Performance of NFTyping.typeBindings: time 0.01733/1.43, allocations: 3.252 MB / 0.8795 GB, free: 3.156 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.002271/1.433, allocations: 353.5 kB / 0.8799 GB, free: 2.812 MB / 0.6231 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 6.2675127582624555] Failed to read output from testmodel.py, exit status != 0: 1.445201724767685 1.470669046 -1.0 Calling exit ...