/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Compressor_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Compressor_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Compressor.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Compressor" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Compressor" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Compressor/model-vnwf86jf" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Compressor" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Compressor.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.010000 LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Compressor/386.fmutmp/sources/ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Compressor_02nls.c:64: Invalid root: (-6.55358)^(0.225296) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Compressor/386.fmutmp/sources/ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Compressor_02nls.c:64: Invalid root: (-0.842597)^(0.225296) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:57:3-59:20:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((noEvent(idealGasConstantGamma3.adiabaticModel.Z_out >= 0.9523809523809523) and noEvent(idealGasConstantGamma3.adiabaticModel.Z_out <= 1.05))) --> "In "Compressor.idealGasConstantGamma3.adiabaticModel" the outlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | debug | Division by zero (T * (data.blow[1] + data.alow[2] * Modelica.Math.log(T) + T * (data.alow[3] + T * (0.5 * data.alow[4] + T * (0.3333333333333333 * data.alow[5] + T * (0.25 * data.alow[6] + 0.2 * data.alow[7] * T))))) - data.alow[1]) / T in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Division by zero (T * (data.blow[1] + data.alow[2] * Modelica.Math.log(T) + T * (data.alow[3] + T * (0.5 * data.alow[4] + T * (0.3333333333333333 * data.alow[5] + T * (0.25 * data.alow[6] + 0.2 * data.alow[7] * T))))) - data.alow[1]) / T in function context LOG_ASSERT | debug | Division by zero (T * (data.blow[1] + data.alow[2] * Modelica.Math.log(T) + T * (data.alow[3] + T * (0.5 * data.alow[4] + T * (0.3333333333333333 * data.alow[5] + T * (0.25 * data.alow[6] + 0.2 * data.alow[7] * T))))) - data.alow[1]) / T in function context LOG_ASSERT | debug | Division by zero (T * (data.blow[1] + data.alow[2] * Modelica.Math.log(T) + T * (data.alow[3] + T * (0.5 * data.alow[4] + T * (0.3333333333333333 * data.alow[5] + T * (0.25 * data.alow[6] + 0.2 * data.alow[7] * T))))) - data.alow[1]) / T in function context LOG_ASSERT | debug | Solving non-linear system 497 failed at time=0. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Compressor/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Compressor" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors