/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise4DieselEngine.AdiabaticPerfectGas_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise4DieselEngine.AdiabaticPerfectGas" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise4DieselEngine.AdiabaticPerfectGas" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise4DieselEngine.AdiabaticPerfectGas/model-zhv454bz" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise4DieselEngine.AdiabaticPerfectGas" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.010000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isobaric.mo:19:3-22:146:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out_fixed >= 273.15 and combustion.T_out_fixed <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out_fixed <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isobaric.mo:64:3-65:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out >= 273.15 and combustion.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:57:3-59:20:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((noEvent(expansion.adiabaticModel.Z_out >= 0.9523809523809523) and noEvent(expansion.adiabaticModel.Z_out <= 1.05))) --> "In "AdiabaticPerfectGas.expansion.adiabaticModel" the outlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Boundaries/LoopBreaker_m.mo:102:3-102:82:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((noEvent(abs(loopBreaker.dp) < loopBreaker.tol_p))) --> "Pressure mismatch in AdiabaticPerfectGas.loopBreaker" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.outlet.state.T >= 273.15 and compression.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.outlet.state.T <= 373.15, has value: 1050.5" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.adiabaticModel.state_out.T >= 273.15 and compression.adiabaticModel.state_out.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.adiabaticModel.state_out.T <= 373.15, has value: 1050.5" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isobaric.mo:62:3-63:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_in >= 273.15 and combustion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_in <= 373.15, has value: 1050.5" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.state_in.T >= 273.15 and expansion.adiabaticModel.state_in.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.state_in.T <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:25:3-26:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.T_in >= 273.15 and expansion.adiabaticModel.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.T_in <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:27:3-27:62:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.T_out_is >= 273.15 and expansion.adiabaticModel.T_out_is <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.T_out_is <= 373.15, has value: 588.448" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.state_out.T >= 273.15 and expansion.adiabaticModel.state_out.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.state_out.T <= 373.15, has value: 588.448" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:20:3-20:48:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.adiabaticModel.T_out >= 273.15 and expansion.adiabaticModel.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.adiabaticModel.T_out <= 373.15, has value: 588.448" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:51:3-52:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((gasExchange.T_in >= 273.15 and gasExchange.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= gasExchange.T_in <= 373.15, has value: 588.448" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Utilities/showRealValue.mo:7:3-8:67:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((exhaustTemperature.number >= 273.15 and exhaustTemperature.number <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= exhaustTemperature.number <= 373.15, has value: 588.448" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:20:3-20:48:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.adiabaticModel.T_out >= 273.15 and compression.adiabaticModel.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.adiabaticModel.T_out <= 373.15, has value: 1050.5" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:27:3-27:62:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.adiabaticModel.T_out_is >= 273.15 and compression.adiabaticModel.T_out_is <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.adiabaticModel.T_out_is <= 373.15, has value: 1050.5" info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.010000 info: Result file: ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise4DieselEngine.AdiabaticPerfectGas_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.combustion.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.compression.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.compression.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.efficiency.description will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.exhaustTemperature.description will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.expansion.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.expansion.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.gasExchange.name will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.loopBreaker.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.maximumPressure.description will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.netWork.description will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_AdiabaticPerfectGas.sensorDensity1.quantityString will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 101 NumRhsEvals = 102 NumLinSolvSetups = 6 NumNonlinSolvIters = 101 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors